User's Guide
SF51 Cordless
Scanner
Document Change Record
This page records changes to this document. The document was
originally released as version 001.
Version Date
Description of Change
002
003
6/2005 Added information to support firmware version
1.1 including these features:
• HID keyboard profile
• SF51 Firmware Upgrade Utility
Removed references to the HID keyboard profile,
which is currently not supported on the SF51.
8/2005
SF51 Cordless Scanner User’s Manual
iii
iv
SF51 Cordless Scanner User’s Manual
Contents
Contents
Before You Begin.................................................................ix
Safety Summary ....................................................ix
Safety Icons............................................................x
Global Services and Support..................................xi
Who Should Read This Document? .....................xii
Related Documents ..............................................xii
Using the SF51................................................................. 1
1
Introducing the SF51 Cordless Scanner ............................... 2
What’s New? ....................................................................... 3
How to Turn On the SF51.................................................. 3
Using the Battery................................................................. 4
Charging the Battery ............................................. 4
Checking the Battery Status................................... 5
Understanding the Lights .................................................... 5
Understanding the Beeps ..................................................... 6
Using Vibrate Alert.............................................................. 7
Scanning Bar Codes............................................................. 8
Collecting Data With Your SF51....................................... 10
Configuring and Managing the SF51.......... 11
2
How to Configure the SF51 Parameters............................. 12
Configuring With EasySet................................... 12
Configuring From Your Intermec Computer....... 13
Restoring Default Settings................................... 14
SF51 Cordless Scanner User’s Guide
v
Contents
Configuring Bluetooth Communications........................... 15
Configuring Security........................................... 15
Configuring the Discoverable State of the SF51 .. 16
Connecting the SF51 to a Host Device.............................. 16
Upgrading Your SF51 ....................................................... 19
Troubleshooting and Maintaining the
3
4
SF51....................................................................................... 23
Troubleshooting the SF51................................................. 24
Getting Information About Your SF51 ............... 24
Problems and Possible Solutions.......................... 25
Locating the SF51 ............................................................. 28
Resetting the SF51 ............................................................ 28
Cleaning the SF51............................................................. 29
Configuration Command Reference............ 31
Using Configuration Commands....................................... 32
Configuration Commands By Function............................. 33
SF51 Configuration Commands........................................ 36
Administrator Reset Factory Defaults.................. 36
Beep Duration .................................................... 36
Beep Frequency................................................... 36
Beep Volume ...................................................... 37
Bluetooth Connect/Disconnect........................... 37
Bluetooth Device Name...................................... 37
Bluetooth Device Page ........................................ 37
Bluetooth Discoverable ....................................... 38
Bluetooth PIN .................................................... 38
Bluetooth Profile................................................. 38
Bluetooth Security............................................... 38
Codabar.............................................................. 39
Codablock A ....................................................... 39
vi
SF51 Cordless Scanner User’s Guide
Contents
Codablock F........................................................ 39
Code 11 .............................................................. 39
Code 39 .............................................................. 39
Code 93/93i........................................................ 40
Code 128 / EAN 128 .......................................... 40
Configuration Modes and Utilities ...................... 40
Consecutive Same Read Data Validation ............. 41
Disable All Symbologies ...................................... 41
Error Beep........................................................... 41
Good Read Beep Duration .................................. 41
Good Read Beep Number ................................... 41
Good Read Beep Timing..................................... 42
Good Read LED Duration.................................. 42
Interleaved 2 of 5................................................. 42
Matrix 2 of 5....................................................... 42
Micro PDF417.................................................... 42
MSI..................................................................... 42
PDF417 .............................................................. 43
Plessey................................................................. 43
Postamble............................................................ 43
Preamble ............................................................. 43
RSS 14 ................................................................ 44
RSS Expanded..................................................... 44
RSS Limited........................................................ 44
Setup Beep .......................................................... 44
Stacked Code Crackle.......................................... 44
Standard 2 of 5.................................................... 44
Symbology Identifier........................................... 45
Telepen............................................................... 45
Timeout Between Different Consecutive Codes... 45
Timeout Between Identical Consecutive Codes ... 46
Trigger Mode...................................................... 46
UPC/EAN .......................................................... 47
User Reset Factory Defaults................................. 47
Vibrate Alert........................................................ 47
Vibrate Alert Duration ........................................ 47
Appendix........................................................................... 49
A
Specifications..................................................................... 50
Accessories for the SF51..................................................... 51
SF51 Cordless Scanner User’s Manual
vii
Contents
Index..................................................................................... 53
I
viii
SF51 Cordless Scanner User’s Guide
Before You Begin
Before You Begin
This section provides you with safety information, technical
support information, and sources for additional product
information.
Safety Summary
Your safety is extremely important. Read and follow all warnings
and cautions in this document before handling and operating
Intermec equipment. You can be seriously injured, and
equipment and data can be damaged if you do not follow the
safety warnings and cautions.
Do not repair or adjust alone
Do not repair or adjust energized equipment alone under any
circumstances. Someone capable of providing first aid must
always be present for your safety.
First aid
Always obtain first aid or medical attention immediately after an
injury. Never neglect an injury, no matter how slight it seems.
Resuscitation
Begin resuscitation immediately if someone is injured and stops
breathing. Any delay could result in death. To work on or near
high voltage, you should be familiar with approved industrial
first aid methods.
Energized equipment
Never work on energized equipment unless authorized by a
responsible authority. Energized electrical equipment is
dangerous. Electrical shock from energized equipment can cause
death. If you must perform authorized emergency work on
energized equipment, be sure that you comply strictly with
approved safety regulations.
SF51 Cordless Scanner User’s Guide
ix
Before You Begin
Safety Icons
This section explains how to identify and understand dangers,
warnings, cautions, and notes that are in this document. You
may also see icons that tell you when to follow ESD procedures
and when to take special precautions for handling optical parts.
A warning alerts you of an operating procedure,
practice, condition, or statement that must be
strictly observed to avoid death or serious injury to
the persons working on the equipment.
Avertissement: Un avertissement vous avertit d’une
procédure de fonctionnement, d’une méthode, d’un
état ou d’un rapport qui doit être strictement
respecté pour éviter l’occurrence de mort ou de
blessures graves aux personnes manupulant
l’équipement.
A caution alerts you to an operating procedure,
practice, condition, or statement that must be
strictly observed to prevent equipment damage or
destruction, or corruption or loss of data.
Attention: Une précaution vous avertit d’une
procédure de fonctionnement, d’une méthode, d’un
état ou d’un rapport qui doit être strictement
respecté pour empêcher l’endommagement ou la
destruction de l’équipement, ou l’altération ou la
perte de données.
Note: Notes are statements that either provide extra
information about a topic or contain special instructions
for handling a particular condition or set of
circumstances.
x
SF51 Cordless Scanner User’s Guide
Before You Begin
Global Services and Support
Warranty Information
To understand the warranty for your Intermec product, visit the
Support. The Intermec Global Sales & Service page appears.
From the Service & Support menu, move your pointer over
Support, and then click Warranty.
Disclaimer of warranties: The sample code included in this
document is presented for reference only. The code does not
necessarily represent complete, tested programs. The code is
provided “as is with all faults.” All warranties are expressly
disclaimed, including the implied warranties of merchantability
and fitness for a particular purpose.
Web Support
our current documents as PDF files. To order printed versions
of the Intermec manuals, contact your local Intermec
representative or distributor.
Visit the Intermec technical knowledge base (Knowledge
Central) at intermec.custhelp.com to review technical
information or to request technical support for your Intermec
product.
Telephone Support
These services are available from Intermec Technologies
Corporation.
In the U.S.A. and
Canada call 1-800-
755-5505 and
Service
Description
choose this option
Factory
Repair and
On-site
Repair
Request a return
1
authorization number for
authorized service center
repair, or request an on-site
repair technician.
Technical
Support
Get technical support on
your Intermec product.
2
SF51 Cordless Scanner User’s Guide
xi
Before You Begin
Telephone Support (continued)
In the U.S.A. and
Canada call 1-800-
755-5505 and
Service
Description
choose this option
Service
Contract
Status
Inquire about an existing
contract, renew a contract,
or ask invoicing questions.
3
4
5
Schedule Site Schedule a site survey, or
Surveys or
Installations
request a product or system
installation.
Ordering
Products
Talk to sales
administration, place an
order, or check the status of
your order.
Outside the U.S.A. and Canada, contact your local Intermec
representative. To search for your local representative, from the
Intermec web site, click Contact.
Who Should Read This Document?
The SF51 Cordless Scanner User’s Guide provides you with
information about the features of the SF51. This guide is written
for the person who is responsible for installing, configuring,
maintaining, and troubleshooting the SF51.
Before you configure the SF51, you should be familiar with
your network and general networking terms, such as IP address.
You should also have a working knowledge of Bluetooth
communications.
Related Documents
current documents that you can download as PDF files.
To order printed versions of the Intermec manuals, contact your
local Intermec representative or distributor.
xii
SF51 Cordless Scanner User’s Guide
Using the SF51
1
Use this chapter to familiarize yourself with the
SF51 Cordless Scanner. This chapter covers these
topics:
• Introducing the SF51 Cordless Scanner
• How to Turn On the SF51
• Using the Battery
• Understanding the Lights
• Understanding the Beeps
• Using Vibrate Alert
• Scanning Bar Codes
• Collecting Data With Your SF51
SF51 Cordless Scanner User’s Guide
1
Chapter 1 — Using the SF51
Introducing the SF51 Cordless Scanner
The SF51 Cordless Scanner is a small, rugged handheld scanner.
It is a lightweight, ergonomically designed scanner that uses a
Bluetooth™ radio for RF communications.
The SF51 includes these features:
Scan button
Scanner
Intermec
Ready-to-Work
indicator
Magnetic connector
Status light
SF51 Cordless Scanner
This device contains permanent magnets that
can generate magnetic fields of greater than 10
gauss. Caution should be used by anyone with a
Pacemaker, Implantable Cardioverter Defibrillator
(ICD), or Heart Failure Device. Check with your
doctor for detailed information before using this
device.
Attention: Cet appareil contient des aimants
permanents qui peuvent produire des champs
magnétiques supérieurs à 10 gauss. Toute
personne munie d’un stimulateur cardiaque,
d’un défibrillateur-cardioverteur implantable
ou d’un appareil visant à pallier les insuffisances
cardiaques doit faire attention. Avant d’utiliser
l’appareil, prenez vos renseignements auprès de
votre médecin.
2
SF51 Cordless Scanner User’s Guide
Chapter 1 — Using the SF51
How to Turn On the SF51
You use the Scan button to turn on the SF51.
To turn on the SF51
• Press the Scan button.
The first time you press the Scan button to turn on the SF51, it
enters a discoverable state so that your host Bluetooth device can
perform a device discovery and establish a Bluetooth connection.
If the status light on the SF51 turns red when you try to turn
on the scanner, you need to charge the battery. For help, see
“Charging the Battery” on page 4.
To turn off the SF51
• Scan this bar code:
Scanner Power Down
\60\08\2A\46
Using the Battery
The SF51 uses a lithium-ion battery as its main power source.
You need to fully charge the battery before you can use the
SF51.
The lithium-ion battery pack that is used in this
device may present a fire or chemical burn hazard
if it is mistreated. Do not disassemble it, heat it
above 100°C (212°F) or incinerate it.
Avertissement: Le paquet de piles d’ions de
lithium qui est utilisé dans cet appareil peut
presenter un risque feu ou un risque chimique de
brûlure s’il est maltraité. Il ne faut pas le
désassembler, le réchauffer à une température plus
élevée que 100°C (212°F) ou l’incinérer.
SF51 Cordless Scanner User’s Guide
3
Chapter 1 — Using the SF51
Charging the Battery
Make sure you fully charge the battery before you start using the
SF51.
To charge the battery
• Place the SF51 in the 1-bay charger (P/N 074645) or the
4-bay charger (P/N 074646). A fully discharged battery
charges to 100% capacity in approximately 3 hours.
It may take longer than 3 hours to charge the battery if the
temperature is near the minimum (0°C, 32°F) or maximum
(45°C, 113°F) charging temperature.
Note: When you place the SF51 in the 1-bay or 4-
bay charger, you reset the SF51 scanner control
firmware. For more information, see “Resetting the
SF51” on page 28.
Checking the Battery Status
• Press the Scan button.
If the status light on the SF51 turns red, the battery is low
(less than 20% battery capacity remaining). You need to
charge the battery now.
Understanding the Lights
The lights on the SF51 turn on to indicate the status of the
battery, a successful decode of a bar code, or the status of the
Bluetooth connection.
4
SF51 Cordless Scanner User’s Guide
Chapter 1 — Using the SF51
Intermec
Ready-to-Work
indicator
Status light
SF51 Lights: The status light turns green or red to indicate the status of the
battery and scanning. The blue Intermec Ready-to-Work™ indicator turns on
to let you know that the SF51 is ready to send data to your host Bluetooth
device.
Status Light Description
Light State
What It Means
Blinks green one time The SF51 successfully decoded a bar
code and sent the data to the host.
The SF51 successfully scanned a
configuration bar code.
Flashes red when you
The battery is low. You need to place
press the Scan button the SF51 in the 1-bay or 4-bay charger.
Flashes red and stays
on for 2 seconds
You scanned a bar code, but the data
was not sent to the host.
You scanned a configuration bar code
and the SF51 did not accept it.
Note: When the SF51 is in the 1-bay or 4-bay
charger, the status light indicates the battery
charging status. For more information, see the
instructions that ship with the charger.
SF51 Cordless Scanner User’s Guide
5
Chapter 1 — Using the SF51
Intermec Ready-to-Work Indicator Description
Light State What It Means
Off
A Bluetooth connection to the host computer is
not established.
Blinking
The SF51 is trying to establish a Bluetooth
connection with the host computer, or the SF51 is
moving out of range of the host computer.
On
A Bluetooth connection with the host computer
has been established. The SF51 is ready to scan
bar codes and send data to the host computer.
Understanding the Beeps
The SF51 uses beeps to give you audio feedback when it
performs some functions. For example, you hear a beep each
time you scan a valid bar code.
SF51 Beeps Description
Beep Sequence
What It Means
Single beep
The SF51 successfully decoded a bar code
or scanned a configuration bar code.
Series of beeps from The SF51 connected to a Bluetooth host.
low to high
Series of beeps from A Bluetooth connection has been lost.
high to low
Three beeps
Data was not successfully sent to the
host. The SF51 is out of range of the
host.
A configuration bar code was not
successfully scanned.
Continuous
beeping for 1
minute
The host PC is paging the SF51. After
you find the SF51, press the Scan button
to stop the beeps. For more information
about paging the SF51, see “Locating the
SF51” on page 28.
6
SF51 Cordless Scanner User’s Guide
Chapter 1 — Using the SF51
You can change the beep volume for your needs and
environment. You can set the beep volume to Low (quiet),
Medium (loud), and High (very loud - default).
Note: To turn off the beeper, you set the Beep
Duration to 0. Turning off the beeper does not
affect the beeps associated with Bluetooth
Connect/Disconnect or Bluetooth Device Page.
You can also change the beeper duration and beeper frequency.
For more information about the beeper commands, see
Chapter 4, “Configuration Command Reference.”
Using Vibrate Alert
You can configure the SF51 to vibrate when a bar code is
successfully decoded. This feature can be useful in these
situations:
• You are in a noisy environment, such as a busy warehouse,
where it can be difficult to hear the beep.
• You are working in a quiet environment, such as a library,
where you do not want to make a lot of noise.
To turn on vibrate alert
• Scan this bar code:
Turn On Vibrate Alert
\60\03\10\48\00\02\40
To turn off vibrate alert
• Scan this bar code:
Turn Off Vibrate Alert
\60\03\10\48\00\00\00
SF51 Cordless Scanner User’s Guide
7
Chapter 1 — Using the SF51
Scanning Bar Codes
The SF51 has a linear imager you can use to scan and enter bar
code data. The linear imager can decode 1D and 2D stacked bar
codes. When you unpack the SF51, these bar code symbologies
are enabled:
• Code 39
• Code 128 / EAN 128
• PDF417 (only available on the SF51 with PDF version)
• UPC/EAN
If you are using bar code labels that are encoded in a different
symbology, you need to enable the symbology on the SF51. Use
EasySet version 5.2 or later to enable and disable symbologies for
your scanner. EasySet is available on the CD that ships with the
SF51, or you can download it at no charge from the Intermec
To scan a bar code label
1 Establish a Bluetooth connection between the SF51 and your
host device. For more information about establishing a
Bluetooth connection, see “Connecting the SF51 to a Host
Device” on page 16.
2 Point the SF51 at the bar code label and hold the SF51 at a
slight angle 15 to 25 cm (6 to 10 in) from the label.
3 Press the Scan button. The scanner beam turns on. Scan this
test bar code:
Code 39 Test Bar Code
*123456*
*123456*
Tip: Depending on your screen resolution, you may be able
to scan bar codes displayed on your computer screen.
4 If you are scanning a 1D bar code, direct the red scanner
beam so that it falls across all bars in the bar code label.
8
SF51 Cordless Scanner User’s Guide
Chapter 1 — Using the SF51
If you are scanning a 2D bar code, pass the beam over the bar
code label in a steady sweeping motion. The scanner emits a
crackle sound.
*INTERMEC*
Scanning With the SF51: There are two different ways to comfortably
hold the SF51.
When the SF51 successfully reads a bar code label, you hear a
single beep and the status light briefly turns green. If Vibrate
Alert is enabled, the SF51 briefly vibrates.
5 Release the Scan button.
Collecting Data With Your SF51
After you connect your SF51 to your host device, you are ready
to start collecting data. The method you use depends on whether
you are using:
• an Intermec computer.
• a host PC.
To collect data using an Intermec computer
1 Establish a Bluetooth connection between the SF51 and your
Intermec computer. For help, see “Connecting the SF51 to a
Host Device” on page 16.
2 Start your data collection application on your Intermec
computer.
SF51 Cordless Scanner User’s Guide
9
Chapter 1 — Using the SF51
3 Scan a bar code with your SF51. The data is entered into
your application.
To collect data using a host PC
1 Establish a Bluetooth connection between the SF51 and your
host PC. For help, see “Connecting the SF51 to a Host
Device” on page 16.
2 Start your data collection application.
3 Configure your data collection application to receive data
from the incoming or outgoing COM port.
4 Scan a bar code with your SF51. The data is entered into
your application.
For more information, see the USB Bluetooth Adapter
Instructions (P/N 074479).
10
SF51 Cordless Scanner User’s Guide
Configuring and
Managing the SF51
2
Use this chapter to understand how to configure
the SF51 to communicate with your application.
This chapter covers these topics:
• How to Configure the SF51 Parameters
• Configuring Bluetooth Communications
• Connecting the SF51 to a Host Device
• Upgrading Your SF51
SF51 Cordless Scanner User’s Guide
11
Chapter 2 — Configuring and Managing the SF51
How to Configure the SF51 Parameters
You can configure many parameters on the SF51, such as the bar
code symbologies it decodes or the volume of the beeper. These
characteristics are controlled by configuration commands. The
values you set for these configuration commands determine how
the scanner operates.
You can configure the SF51:
• using EasySet version 5.2 or later either online or offline.
• remotely from your Intermec computer.
Configuring With EasySet
EasySet is an Intermec configuration application that provides
you with two ways to configure the SF51:
• Online: Send configuration commands directly to the SF51.
• Offline: Send configuration commands to a bar code setup
sheet. You can scan the bar codes onscreen with your SF51 or
print the setup sheet and scan the bar codes. You do not need
a Bluetooth connection to use this method.
To configure the SF51 online with EasySet
1 Establish a Bluetooth connection with your host PC. For
help, see the For help, see the USB Bluetooth Adapter
Instructions (P/N 074479).
2 Start EasySet. The first time you start EasySet, the Select
product dialog box appears.
If the Select product dialog box does not appear, choose
Product > Select.
3 Select the SF51.
4 Select the Online Setup check box, and click OK. The
Online Setup dialog box appears.
5 Select the COM port that your SF51 is using for Bluetooth
communications, and click OK.
EasySet connects to your SF51 and retrieves the current
configuration of the SF51.
12
SF51 Cordless Scanner User’s Guide
Chapter 2 — Configuring and Managing the SF51
6 In the Commands window, choose configuration command
settings for your SF51.
Your SF51 is updated with the new configuration command
settings, and the settings are added to the bar code setup sheet.
Note: The SF51 does not beep when you send
configuration commands online from EasySet.
To configure the SF51 offline with EasySet
1 Start EasySet. The first time you start EasySet, the Select
product dialog box appears.
If the Select product dialog box does not appear, choose
Product > Select.
2 Select the SF51, and click OK.
3 In the Commands window, choose configuration command
settings for your SF51 and add them to the bar code setup
sheet.
4 Scan the bar codes onscreen with your SF51, or print the
setup sheet and scan the commands. When you scan bar code
configuration commands, the SF51 emits a series of beeps
unless the volume is turned off.
• One beep means you scanned a valid configuration
command.
• Three beeps means you scanned an invalid configuration
command.
For more information about EasySet, see the EasySet software.
For descriptions of the configuration commands, see Chapter 4,
“Configuration Command Reference.”
Configuring From Your Intermec Computer
You can configure many settings for the SF51 from your
Intermec computer. For descriptions of the configuration
commands, see Chapter 4, “Configuration Command
Reference.”
SF51 Cordless Scanner User’s Guide
13
Chapter 2 — Configuring and Managing the SF51
To configure the SF51 from your Intermec computer
Note: When you connect to an Intermec computer,
all SF51 settings that are common to the Intermec
computer’s internal scanner settings are changed to
the default settings of the internal scanner.
1 Establish a Bluetooth connection with your Intermec
computer. For help, see the procedure “To connect to an
Intermec computer” on page 17.
2 On your Intermec computer, start the Intermec Settings
application.
3 Select Data Collection > SF51 Scanner Bluetooth Address,
where Bluetooth Address is the Bluetooth address of your SF51.
4 Configure commands from the SF51 Scanner menu for your
SF51.
5 Select File > Save Settings. The SF51 is updated with the
new configuration command settings.
6 Close Intermec Settings.
Restoring Default Settings
You can restore the SF51 to its default settings by scanning the
Administrator Reset Factory Defaults command. For a list of the
default settings, see “Configuration Commands by Function” on
page 33.
Note: Using the Administrator Reset Factory
Defaults command resets all parameters. As a result,
you will lose Bluetooth communications.
To restore default settings
• Scan this bar code:
Administrator Reset Factory Defaults
\60\08\55\22
14
SF51 Cordless Scanner User’s Guide
Chapter 2 — Configuring and Managing the SF51
Configuring Bluetooth Communications
The SF51 can communicate with a host device through the
Serial Port Profile (SPP) Bluetooth communications profile.
SPP allows the SF51 to use the Bluetooth link as a serial port to
communicate with the host device. You can send information
from the SF51 to your serial application without having to
modify your application.
You can initiate a Bluetooth connection from either your SF51
or host device:
• If you initiate the connection from your SF51, you can only
connect one SF51 to your host device. When you reset the
SF51 by placing it in a charger, the SF51 automatically
reestablishes the Bluetooth connection.
• If you initiate the connection from a host device, you can
connect more than one SF51 to the same host device. When
you reset the SF51 by placing it in a charger, you need to
reestablish the Bluetooth connection from your host device.
Configuring Security
The SF51 provides Bluetooth wireless security for transmitting
data. By default, security is active on your SF51. For maximum
security, you need to configure a Bluetooth PIN (personal
identification number).
This section assumes that you have already installed EasySet
version 5.2 or later.
To configure a Bluetooth PIN for your SF51
1 Start EasySet version 5.2 or later.
2 In the Commands window, select Data transmission
settings > Bluetooth parameters > security.
3 Select active.
4 Select compose PIN and create a Bluetooth PIN that is up to
16 characters in length. The default Bluetooth PIN is 0000.
5 Scan both commands onscreen with your SF51, or print the
bar code setup sheet and scan both commands.
SF51 Cordless Scanner User’s Guide
15
Chapter 2 — Configuring and Managing the SF51
Note: For security reasons, you can only change
the Bluetooth PIN by scanning a bar code.
Configuring the Discoverable State of the SF51
By default, the SF51 is always discoverable. For enhanced
security, you should configure your SF51 for limited
discoverability, which allows the SF51 to be discoverable by
Bluetooth management applications for only 30 seconds. For
more information, see “Bluetooth Discoverable” on page 38.
To configure your SF51 for limited discoverability
• Scan this bar code:
Bluetooth parameters - discoverable - limited
\60\02\50\41\00\02\40
The SF51 is discoverable for 30 seconds.
Connecting the SF51 to a Host Device
You can use Bluetooth radio communications to connect the
SF51 to these host devices:
• Intermec computer with a Bluetooth radio, such as the 700
Color Series (with Windows Mobile 2003 or later), CK30,
and CK60
• PC with a USB Bluetooth adapter (P/N 074892)
• Other devices with a Bluetooth radio that support a Serial
Port Profile (SPP)
Before connecting the SF51 to a host device, note the Bluetooth
address for the:
• host Bluetooth device.
• SF51.
16
SF51 Cordless Scanner User’s Guide
Chapter 2 — Configuring and Managing the SF51
Bluetooth
address
SF51 Bluetooth Address: The SF51 Bluetooth address is located in the upper
right corner of the label on the back of the SF51.
To connect to an Intermec computer
Note: When you connect to an Intermec computer,
all SF51 settings that are common to the Intermec
computer’s internal scanner settings are changed to
the default settings of the internal scanner.
1 Install EasySet version 5.2 or later on a host PC. EasySet is
available on the CD that shipped with the SF51 or from the
2 Start EasySet. Make sure that SF51 is selected as your
product.
3 From the EasySet commands window, select Data
transmission settings > Bluetooth parameters >
connect/disconnect.
4 Double-click compose BT address.
5 Enter the Bluetooth address of your Intermec computer and
click OK. The bar code appears on the setup sheet.
6 Scan the bar code onscreen with the SF51, or print the bar
code setup sheet and scan the bar code. The SF51 beeps once,
the green status light flashes once, and the blue Intermec
Ready-to-Work indicator starts blinking.
SF51 Cordless Scanner User’s Guide
17
Chapter 2 — Configuring and Managing the SF51
When the SF51 connects to your Intermec computer, the
SF51 emits a series of beeps from low to high, and the blue
Intermec Ready-to-Work indicator turns on and stays on.
The SF51 is ready to scan data.
Note: To connect more than one SF51 to your
Intermec computer, use the Bluetooth Device Utility
or the Bluetooth control panel on the Intermec
computer. For help, see the documentation for your
Intermec computer.
To connect to a host PC with the USB Bluetooth adapter
1 Install EasySet version 5.2 or later. EasySet is available on the
CD that shipped with the SF51 or from the Intermec web
2 Install the USB Bluetooth adapter (P/N 074892) and
software on your host PC.
3 Connect and pair your SF51 with your host PC.
For help, see the USB Bluetooth Adapter Instructions (P/N
074479) that ship with the adapter.
To disconnect from a host PC
• Scan this bar code:
Bluetooth Device Disconnect
\60\02\52\05\00\00\06\00\00\00\00\00\00\00\00\00
The SF51 disconnects from your host PC, emits a series of
beeps from high to low, and the blue Intermec Ready-to-
Work indicator turns off.
Tip: Depending on your screen resolution, you may be able
to scan bar codes displayed on your computer screen.
18
SF51 Cordless Scanner User’s Guide
Chapter 2 — Configuring and Managing the SF51
Upgrading Your SF51
When you upgrade your SF51, you update the SF51 processor
firmware. The current settings are erased and replaced with the
default settings for the SF51. You need to reestablish Bluetooth
communications between your SF51 and other Bluetooth
devices and applications in your data collection system.
To upgrade the SF51, you need these items:
• SF51 firmware upgrade package:
• SF51Upgrade.exe (SF51 Firmware Upgrade Utility)
• SF51_01_01.ldr (firmware upgrade file)
• readme.txt (upgrade instructions)
• USB Bluetooth adapter (P/N 074892)
• PC running Microsoft Windows 2000/XP with SP1 or SP2
To upgrade the SF51
1 Download the latest upgrade package from the Intermec web
a Go to Service & Support > Downloads.
b From the Select A Product drop-down list, choose Bar
Code Scanners: SF51 Cordless Scanner.
c Click the link to download the upgrade package, and save
it to your PC.
2 Fully charge the SF51 battery. For help, see “Charging the
Battery” on page 4.
3 Remove the SF51 from the charger.
4 If necessary, install the USB Bluetooth adapter (P/N 074892)
and create a Bluetooth connection between your SF51 and
your PC. For help, see the USB Bluetooth Adapter Instructions
(P/N 074479) that ship with the adapter.
Note: Make sure that all applications on your PC are
closed.
5 Start the SF51 Firmware Upgrade Utility.
SF51 Cordless Scanner User’s Guide
19
Chapter 2 — Configuring and Managing the SF51
6 Click Browse to browse to the location of the firmware (.ldr)
file.
7 Select the firmware file and click Open.
8 From the COM Port drop-down list box, select the COM
port that the SF51 is using for Bluetooth communications.
9 Click Next. The upgrade utility gets the Bluetooth address
and current version of firmware on your SF51.
10 Click Upgrade. The status bar appears and the upgrade
utility upgrades your SF51 with the latest firmware.
Note: Do not place the SF51 in the 1-bay or 4-bay
charger during the firmware upgrade, because the
SF51 may lock up.
11 The upgrade utility notifies you when the upgrade is
complete.
Troubleshooting the Firmware Upgrade
If the SF51 locks up during the upgrade procedure and does not
respond when you press the Scan button or place it in a charger,
you may still be able to connect to it from your PC and upgrade
the firmware.
To troubleshoot a locked up SF51
1 Make sure that the SF51 is not seated in the 1-bay or 4-bay
charger.
2 From your PC, use the Bluetooth application to search for
Bluetooth devices.
3 If your SF51 appears in the list, connect to it from the
Bluetooth application.
If your SF51 does not appear in the list, contact Intermec
Support Services at 1-800-755-5505.
4 When the Bluetooth PIN Code Request box appears, enter
the following case-sensitive PIN in the Bluetooth PIN Code
field, and click OK:
zxcvasdfqwer
20
SF51 Cordless Scanner User’s Guide
Chapter 2 — Configuring and Managing the SF51
The Bluetooth application connects to the boot loader code
on your SF51. “Intermec SF51 Boot Server” may appear in
the Device Name list instead of the name of your SF51
scanner.
5 Use your Bluetooth application to connect to the Intermec
SF51 Boot Server.
6 Start the SF51 Firmware Upgrade Utility.
7 Click Browse to browse to the location of the firmware (.ldr)
file. Select the firmware file and click Open.
8 From the COM Port drop-down list box, select the COM
port that the Intermec SF51 Boot Server is using for
Bluetooth communications.
9 Click Next. The Bluetooth address of your SF51 appears, the
status bar appears, and the upgrade utility upgrades your
SF51 with the latest firmware.
Note: The next time you connect to your PC, your
SF51 device name may be “Intermec SF51 Boot
Server.” When the Bluetooth PIN Code Request box
appears, enter the default PIN, which is 0000. After
you connect, the name and Bluetooth address of your
SF51 should appear in your Bluetooth application.
SF51 Cordless Scanner User’s Guide
21
Chapter 2 — Configuring and Managing the SF51
22
SF51 Cordless Scanner User’s Guide
Troubleshooting
and Maintaining the
SF51
3
Use this chapter to solve problems you may have
while using the SF51. This chapter contains
these topics:
• Troubleshooting the SF51
• Locating the SF51
• Resetting the SF51
• Cleaning the SF51
SF51 Cordless Scanner User’s Guide
23
Chapter 3 — Troubleshooting and Maintaining the SF51
Troubleshooting the SF51
If you have problems using the SF51, use this chapter to find a
possible solution.
Getting Information About Your SF51
You can use Configuration Modes and Utilities commands to
get the following product information about your SF51:
• Product version
• Sub-system versions
• Bluetooth address of your SF51
These commands can also be useful if you need to call Intermec
Product Support.
To get the product version, sub-system versions, or Bluetooth address
1 If necessary, install the USB Bluetooth adapter (P/N 074892)
and create a Bluetooth connection between your SF51 and
your PC. For help, see the USB Bluetooth Adapter Instructions
(P/N 074479) that ship with the adapter.
2 Run an application that can accept bar code information
from the SF51, such as HyperTerminal.
3 Scan one of these bar codes:
Get Product Version
Get Sub-System Versions
\60\0F\37\20
\60\0F\37\24
Get SF51 Bluetooth Device Address
\60\0F\37\23
Tip: Depending on your screen resolution, you may be able
to scan bar codes displayed on your computer screen.
24
SF51 Cordless Scanner User’s Guide
Chapter 3 — Troubleshooting and Maintaining the SF51
Problems and Possible Solutions
Problem
Possible Solution
Your SF51 has been
misplaced, and you cannot
find it.
If your SF51 is within Bluetooth
communication range of your host
PC, you can send the Bluetooth
Device Page command from EasySet
to locate your SF51. For help, see
“Locating the SF51” on page 28.
You place the SF51 in a
charger and lose Bluetooth
communications.
When you place the SF51 in a 1-bay
or 4-bay charger, you reset the SF51,
and the scanner control firmware
restarts. If you have a Bluetooth
connection, the SF51 disconnects
from the host device while the
firmware resets. For more
information, see “Resetting the
SF51” on page 28.
You cannot establish a
Scan the following bar code to
reset the scanner to its default
configuration and try establishing
a connection again.
Bluetooth connection (the
blue Intermec Ready-to-
Work indicator is not on).
Administrator Reset Factory Defaults
\60\08\55\22
Note: Using the Administrator Reset
Factory Defaults command resets all
settings. As a result, you will lose
Bluetooth communications.
SF51 Cordless Scanner User’s Guide
25
Chapter 3 — Troubleshooting and Maintaining the SF51
Problems and Possible Solution (continued)
Problem
Possible Solution
You are trying to establish a
The SF51 may not be in a
Bluetooth connection from a discoverable state. For help, see
host device to your SF51, but “Bluetooth Discoverable” on
the host device cannot find
your SF51.
page 38.
The SF51 may be connected and
paired to another Bluetooth device.
Scan the following bar code to
reset the SF51 to its default settings
and disconnect Bluetooth
communications. Try establishing a
connection again.
Administrator Reset Factory Defaults
\60\08\55\22
Note: Using the Administrator Reset
Factory Defaults command resets all
settings. As a result, you will lose
Bluetooth communications.
You established a Bluetooth
When you connect to an Intermec
connection with an Intermec computer, all SF51 settings that are
computer, and the settings
on your SF51 were restored
to their default values.
common to the Intermec computer’s
internal scanner settings are changed
to the default settings of the internal
scanner. Scan configuration bar
codes, or use Intermec Settings on
your Intermec computer to change
your SF51 settings.
26
SF51 Cordless Scanner User’s Guide
Chapter 3 — Troubleshooting and Maintaining the SF51
Problems and Possible Solution (continued)
Problem
Possible Solution
You changed the Bluetooth
Scan this bar code to reset the
PIN from its default value of scanner to its default configuration
0000, but you forgot your
new PIN number.
and default Bluetooth PIN of 0000.
Administrator Reset Factory Defaults
\60\08\55\22
When you press the Scan
button, the Status light
flashes red.
The battery is low. Charge the
battery immediately and try scanning
again.
When you press the Scan
The battery is low. Charge the
button, the red scanner beam battery immediately and try scanning
does not turn on.
again.
You try to scan a bar code,
and nothing happens.
You may not have a Bluetooth
connection. Make sure the blue
Intermec Ready-to-Work indicator is
on. For help, see “Connecting the
SF51 to a Host Device” on page 16.
The data may still be in the process
of being sent to the host. Data
transmission may be slow if there
is interference with Bluetooth
communications, or if the SF51 is
too far from the host device. Try
moving closer to the host device.
You scan a bar code, the
Status light flashes red for
The SF51 may not be connected to a
host. Make sure the blue Intermec
two seconds, and the scanner Ready-to-Work indicator is on and
beeps three times.
the SF51 is connected to your host
device. For help, see “Connecting
the SF51 to a Host Device” on
page 16.
SF51 Cordless Scanner User’s Guide
27
Chapter 3 — Troubleshooting and Maintaining the SF51
Locating the SF51
If your SF51 is within Bluetooth communication range of your
host PC, you can send the Bluetooth Device Page command
from EasySet to locate the SF51.
Note: If the SF51 is turned off, your host PC
cannot connect to it and send the Bluetooth Device
Page command.
To page the SF51
1 Start EasySet version 5.2 or later. Make sure that SF51 is
selected as your product.
2 Select Communication > Connect.
3 Select the appropriate COM port, and click OK.
4 Select the Send to product check box below the commands
window.
5 In the EasySet Commands window, select Configuration
modes and utilities > Bluetooth device page.
The SF51 beeps continuously for 1 minute or until you find
the SF51 and press the Scan button.
Resetting the SF51
If the SF51 appears to be locked up, you can reset it. When you
reset the SF51, the scanner control firmware is restarted.
To reset the SF51
• Place the SF51 in the 1-bay or 4-bay charger.
If you have a Bluetooth connection, the SF51 disconnects from
the host device.
28
SF51 Cordless Scanner User’s Guide
Chapter 3 — Troubleshooting and Maintaining the SF51
When you reset the SF51:
• The SF51 tries to reestablish a Bluetooth connection with the
host device if the SF51 initiated the Bluetooth connection.
• The SF51 turns on and enters a discoverable state if the host
device initiated the Bluetooth connection. You need to
reestablish the Bluetooth connection from the host device.
Cleaning the SF51
To keep the SF51 in good working order, you may need to
clean the scanner window. Clean the scanner window as often
as needed for the environment in which you are using the SF51.
To clean the scanner window, you can use soapy water, a
solution of ammonia and water, or isopropyl alcohol.
Opening the SF51 will void the warranty and may
cause damage to the internal components.
Attention: Le fait d’ouvrir le SF51 annule la garantie
et peut endommager les pièces internes.
To clean the scanner window
1 Dip a clean towel or rag in soapy water, ammonia and water
solution, or isopropyl alcohol and wring out the excess. Wipe
the scanner window. Do not allow any abrasive material to
touch the window.
2 Wipe dry with a lint-free cloth.
SF51 Cordless Scanner User’s Guide
29
Chapter 3 — Troubleshooting and Maintaining the SF51
30
SF51 Cordless Scanner User’s Guide
Configuration
Command Reference
4
Use this chapter to learn about the commands
supported on the SF51. This chapter contains
these topics:
• Using Configuration Commands
• Configuration Commands By Function
• SF51 Configuration Commands
SF51 Cordless Scanner User’s Guide
31
Chapter 4 — Configuration Command Reference
Using Configuration Commands
A configuration command changes the way the SF51 operates.
For example, you can change the Beep Volume and make the
SF51 beeper very quiet for a quiet environment.
You can configure the SF51:
• using EasySet online. Send commands to your SF51 from
your PC using EasySet. For help, see the procedure “To
configure the SF51 online with EasySet” on page 12.
• using EasySet offline. Send commands to a bar code setup
sheet. Then, scan the bar codes onscreen with your SF51, or
print the setup sheet and scan the bar codes. You do not need
a Bluetooth connection to use this method. For help, see the
procedure “To configure the SF51 offline with EasySet” on
page 13.
• from your Intermec computer. Send commands to your SF51
from your Intermec computer using Intermec Settings. For
help, see the procedure “To configure the SF51 from your
Intermec computer” on page 14.
Note: When you connect to an Intermec computer,
all SF51 settings that are common to the Intermec
computer’s internal scanner settings are changed to
the default settings of the internal scanner.
For a list of all the commands and their default values as they are
organized in EasySet, see the next section, “Configuration
Commands By Function.”
For descriptions of each command organized alphabetically, see
“SF51 Configuration Commands” on page 36.
32
SF51 Cordless Scanner User’s Guide
Chapter 4 — Configuration Command Reference
Configuration Commands By Function
The configuration commands are grouped by function and
reflect the organization of the Commands window in EasySet.
Reset All Parameters
Command
Default Value
See Page
Administrator reset factory
defaults
N/A
36
User reset factory defaults
N/A
47
Data Transmission Settings
Bluetooth Command
Default Value
See Page
Bluetooth security
Bluetooth PIN
Active
0000
38
38
Bluetooth discoverable
Bluetooth profile
Fully discoverable
38
38
Serial port profile
(SPP)
Bluetooth device name
SF51 Scanner
<Bluetooth Address>
37
37
Bluetooth
Disconnect
connect/disconnect
Data Transmission
Command
Default Value
<CR><LF>
None
See Page
Postamble
43
43
45
Preamble
Symbology identifier
Not transmitted
SF51 Cordless Scanner User’s Guide
33
Chapter 4 — Configuration Command Reference
Symbology Settings
Symbology
Default Value
N/A
See Page
Disable all symbologies
Codabar
41
39
Not active
Codablock
Codablock A
Codablock F
Not active
Not active
39
39
Code 11
Not active
Active
39
39
40
Code 39
Code 93/93i
Not active
Code 128 / EAN 128
ISBT 128
Active
Active
Not active
40
40
40
GTIN processing
Interleaved 2 of 5
Matrix 2 of 5
Micro PDF417
MSI
Not active
Not active
Not active
Not active
Active
42
42
42
42
43
43
PDF417
Plessey
Not active
RSS
RSS 14
RSS Expanded
RSS Limited
Not active
Not active
Not active
44
44
44
Standard 2 of 5
Telepen
Not active
Not active
44
45
UPC/EAN
ISBN
Active
Not active
Not active
47
47
47
GTIN processing
Note: Stacked 2D bar code symbologies are not
available on the non-PDF version of the SF51. For
more information about setting symbology options,
see the EasySet software.
34
SF51 Cordless Scanner User’s Guide
Chapter 4 — Configuration Command Reference
Operating Settings
Trigger Activation
Command
Default Value
See Page
Trigger mode
Level
46
Data Decoding
Security Command
Default Value
See Page
Consecutive same read
data validation
Auto read count
before transmission
41
Timeout between identical
consecutive codes
300 ms
None
46
45
Timeout between different
consecutive codes
Beeps/Green Indicator LED
Command
Default Value
High
See Page
Beep volume
37
36
Note (Beep frequency)
2610 Hz
Good read beeps
Number
1
41
41
42
Duration
Timing
80 ms
After transmission
Good read LED duration
2000 ms
42
41
44
Error beep
On
Setup beep
On
2D symbologies
Stacked code crackle
On
44
Vibrate alert
Vibrate alert
Duration
Off
300 ms
47
47
SF51 Cordless Scanner User’s Guide
35
Chapter 4 — Configuration Command Reference
Configuration Modes and Utilities
Command
Default Value
See Page
Configuration modes and
utilities
Configuration
Enabled
40
Bluetooth device page
N/A
37
SF51 Configuration Commands
This section lists the configuration commands in alphabetical
order and provides a description of each command. To
configure your SF51 using these commands, see the EasySet
software.
Administrator Reset Factory Defaults
Causes the SF51 to perform a restart and restores all
configuration commands to their default settings. When you
restore all configuration commands to their default settings, you
need to reestablish Bluetooth communications.
Beep Duration
Sets the length of the beeps. You can set Beep Duration to a
value from 0 to 2550 ms. When Beep Duration is set to 0 ms,
the beeper is off. Turning off the beeper does not affect the
beeps associated with Bluetooth Connect/Disconnect or
Bluetooth Device Page.
Use Beep Duration in combination with Beep Frequency and
Beep Volume to define beeps according to operator preference
and work environment.
Beep Frequency
Sets the frequency, or pitch, of the beeps. You can set Beep
Frequency to a value from 1000 to 5110 Hz.
36
SF51 Cordless Scanner User’s Guide
Chapter 4 — Configuration Command Reference
Use Beep Frequency in combination with Beep Volume and
Good Read Beep Duration to define beeps according to operator
preference and work environment.
Beep Volume
Adjusts the volume of the beeps. You can set Beep Volume to
Low, Medium, or High.
Note: To turn off the beeper, you set the Beep
Duration to 0. Turning off the beeper does not
affect the beeps associated with Bluetooth
Connect/Disconnect or Bluetooth Device Page.
Use Beep Volume in combination with Beep Frequency and
Good Read Beep Duration to define beeps according to operator
preference and work environment.
Bluetooth Connect/Disconnect
Connects or disconnects Bluetooth communications between
the SF51 and host computer if you are using Serial port profile.
To connect to a host computer, enter the Bluetooth address
of the computer and scan the bar code with the SF51. To
disconnect, scan the disconnect bar code.
Bluetooth Device Name
Sets the name of the scanner. If the scanner is in a discoverable
state, its Bluetooth device name is available to host computers
during device discovery.
Bluetooth Device Page
If your SF51 is within Bluetooth communication range of your
host PC, you can send this command from EasySet to locate the
SF51. For help, see “Locating the SF51” on page 28.
SF51 Cordless Scanner User’s Guide
37
Chapter 4 — Configuration Command Reference
Bluetooth Discoverable
Determines the discoverable state of the SF51.
Bluetooth Discoverable States
State
Description
Fully
The SF51 is discoverable to Bluetooth management
applications.
Limited
Not
The SF51 is discoverable to Bluetooth management
applications for 30 seconds.
The SF51 is not discoverable to Bluetooth management
applications.
Note: The SF51 is not discoverable when it is
connected to a host device.
Bluetooth PIN
When Bluetooth security is enabled, the Bluetooth PIN is
used to authenticate the Bluetooth link and encrypt the data.
Depending on the Bluetooth software on your host device, you
should only need to enter the Bluetooth PIN the first time you
connect and pair the SF51.
For help configuring a Bluetooth PIN, see “Configuring
Security” on page 15.
Bluetooth Profile
Configures the SF51 to connect to a host device through
the Serial Port Profile (SPP) Bluetooth communications profiles.
SPP allows the SF51 to use the Bluetooth link as a serial port to
communicate with the host device.
For more information, see “Configuring Bluetooth
Communications” on page 15.
Bluetooth Security
Enables or disables Bluetooth security. When Bluetooth
security is enabled, you need to enter the SF51 Bluetooth PIN
38
SF51 Cordless Scanner User’s Guide
Chapter 4 — Configuration Command Reference
before you can use the scanner. For more information, see
“Configuring Security” on page 15.
Codabar
Enables or disables decoding of Codabar symbology. Codabar
is a self-checking, discrete symbology. The American Blood
Commission (ABC) Codabar requires that you retain and
transmit the start/stop code digits when processing a Codabar
symbol. As a result, configuration CD10 is an illegal
configuration.
Codablock A
Enables or disables decoding of Codablock A symbology.
Codablock A is a 2D bar code that is an extension of Code 39.
If Code 39 is enabled with check digit, you cannot enable
Codablock A. For best results, disable Code 39 before you
enable Codablock A. If Code 39 is enabled with check digit,
Codablock A will not be decoded properly.
Codablock F
Enables or disables decoding of Codablock F symbology.
Codablock F is a 2D bar code that is an extension of Code 128.
If Code 128 is enabled with check digit, you cannot enable
Codablock F. For best results, disable Code 128 before you
enable Codablock F.
Code 11
Enables or disables decoding of Code 11 symbology. Code 11 is
a very high-density, discrete numeric bar code. It is most
extensively used in labeling telecommunications components
and equipment.
Code 39
Enables or disables decoding of Code 39 symbology. Code 39 is
discrete, variable length, and self-checking. The character set is
uppercase A to Z, 0 to 9, dollar sign ($), period (.), slash (/),
percent (%), space ( ), plus (+), and minus (-).
SF51 Cordless Scanner User’s Guide
39
Chapter 4 — Configuration Command Reference
Code 93/93i
Enables or disables decoding of Code 93/93i symbology. Code
93/93i is a variable length, continuous symbology that uses four
element widths.
Code 128 / EAN 128
Enables or disables decoding of Code 128 / EAN 128
symbology. Code 128 is a very high-density alphanumeric
symbology that supports the extended ASCII character set. It is a
variable length, continuous code that uses multiple element
widths.
ISBT 128
Enables and configures decoding of ISBT Code 128 symbology.
ISBT Code 128 is the global bar code labeling standard for the
blood banking industry. It is used to support the worldwide
distribution, tracking, and handling of blood bags and blood
components.
GTIN Processing for EAN 128
With GTIN processing enabled, a GTIN compliant EAN 128
label will have the first two digits stripped and output 14 digits.
A GTIN (Global Trade Item Number) compliant EAN 128
label:
• is 16 digits long.
• has “01” as the first two digits of the label.
Configuration Modes and Utilities
Use Configuration Modes and Utilities to:
• allow the SF51 to always accept configuration commands by
scanning bar codes or to timeout 1 minute after the last
configuration command is set by scanning a bar code.
• get the product version, sub-system versions, and Bluetooth
address of your SF51.
• page the SF51 from your host PC or turn off the SF51.
For more information and bar codes, see “Getting Information
About Your SF51” on page 24.
40
SF51 Cordless Scanner User’s Guide
Chapter 4 — Configuration Command Reference
Consecutive Same Read Data Validation
To increase decode security, you can have the scanner scan a bar
code multiple times to ensure you have a valid read before
transmitting the data.
You can set Consecutive Same Read Data Validation from 0 to
10. The default value of 0 sets the scanner to automatically
adapt the consecutive same read based on the bar code quality
and the trust level of the bar code. For example, labels with a
check digit require less reads than labels without a check digit.
Disable All Symbologies
This command disables all symbologies. Disabling all
symbologies does not reset symbology parameters to their default
values. To reset all symbology parameters to their default factory
settings, use the Administrator Reset Factory Defaults
command. For more information, see “Administrator Reset
Factory Defaults” on page 36.
Error Beep
Enables or disables the error beep. When you scan a
configuration bar code that is damaged or unknown, you
hear an error beep, and the configuration of the SF51 is not
changed.
Good Read Beep Duration
Sets the length of the SF51 good read beeps. You can set Good
Read Beep Duration to a value from 0 (off) to 2550 ms.
Use Good Read Beep Duration in combination with Beep
Volume and Beep Frequency to define beeps according to
operator preference and work environment.
Good Read Beep Number
Determines the number of beeps used for the good read beep: 1,
2, or none.
SF51 Cordless Scanner User’s Guide
41
Chapter 4 — Configuration Command Reference
Good Read Beep Timing
Determines if the good read beep happens before or after
successfully transmitting data.
Good Read LED Duration
Sets the amount of time the green Status light stays on after a
good read. You can set Good Read LED Duration to a value
from 0 (off) to 5110 ms. When the Status light is on due to a
long duration time, the SF51 can still read new bar codes and
receive commands.
Interleaved 2 of 5
Enables or disables decoding of Interleaved 2 of 5 symbology.
Interleaved 2 of 5 is a high-density, self-checking, continuous
numeric symbology. It is mainly used in inventory distribution
and the automobile industry.
Matrix 2 of 5
Enables or disables decoding of Matrix 2 of 5 symbology. Matrix
2 of 5 is a discrete bar code derived from Code 11.
Micro PDF417
Enables or disables decoding of Micro PDF417 symbology.
Micro PDF417 is a multi-row symbology based on PDF417. It
is designed to maximize area efficiency for applications that do
not need the maximum data capacity of PDF417. Micro
PDF417 contains a limited set of symbol sizes that each includes
a fixed level of error correction.
MSI
Enables or disables decoding of MSI symbology. MSI code is
similar to Plessey code in that it includes a start pattern, data
characters, one or two check digits, and a stop pattern.
42
SF51 Cordless Scanner User’s Guide
Chapter 4 — Configuration Command Reference
PDF417
PDF417 is only supported on the SF51 with PDF version.
Enables or disables decoding of PDF417 symbology. The
PDF417 symbology is a stacked 2D symbology that allows you
to scan across rows of code. Each row consists of start/stop
characters, row identifiers, and symbol characters, which consist
of four bars and four spaces each and contain the actual data.
This symbology uses error correction symbol characters
appended at the end to recover loss of data.
Macro PDF417, a feature of PDF417, extends the capability of
PDF417 by allowing up to 99,999 PDF417 symbols to be used
to store data. The symbols are concatenated as they are scanned
and can be scanned in any order.
Plessey
Enables or disables decoding of Plessey symbology. Plessey code
is pulse-width modulated like most other bar codes. It includes a
start character, data characters, an eight-bit cyclic check digit, a
termination bar, and usually a reverse start character. The code is
continuous and not self-checking. You need to configure two
parameters for Plessey code: Start Code and Check Digit.
Postamble
Sets the postamble that is appended to any data you scan.
Common postambles include cursor controls such as a tab
or a carriage return line feed. You can set Postamble to up to 20
ASCII characters.
Preamble
Sets the preamble that precedes any data you scan. Common
preambles include a data location number or an operator
number. You can set Preamble to up to 20 ASCII characters.
SF51 Cordless Scanner User’s Guide
43
Chapter 4 — Configuration Command Reference
RSS 14
Enables or disables decoding of RSS 14 (Reduced Space
Symbology 14) 1D or stacked 2D codes. RSS 14 is a numeric
symbology that can read stacked omni-directional bar code
labels. It is a member of the EAN.UCC RSS symbology family.
Note: To read RSS 14 stacked 2D codes, RSS
Expanded or RSS Limited must also be enabled.
RSS Expanded
Enables or disables decoding of RSS Expanded (Reduced Space
Symbology Expanded). RSS Expanded is an alphanumeric
symbology that can read RSS limited and stacked bar code
labels. It is a member of the EAN.UCC RSS symbology family.
RSS Limited
Enables or disables decoding of RSS Limited (Reduced Space
Symbology Limited). RSS Limited is a numeric symbology that
does not read stacked bar code labels. It is a member of the
EAN.UCC RSS symbology family.
Setup Beep
Enables or disables the setup beep. When you successfully scan a
configuration bar code, you hear the setup beep, and the
configuration of the SF51 is changed.
Stacked Code Crackle
Enables or disables the crackle sound when you scan a stacked
(2D) bar code.
Standard 2 of 5
Enables or disables decoding of Standard 2 of 5 symbology.
Standard 2 of 5 is a low-density numeric symbology. It encodes
all information in the bars and uses the fixed-width spaces to
separate the bars. Standard 2 of 5 is used in warehouse sorting,
photofinishing, and airline tickets.
44
SF51 Cordless Scanner User’s Guide
Chapter 4 — Configuration Command Reference
Symbology Identifier
Symbology identifiers allow you to indicate what type of data is
being sent by prepending an identifier to the data. You can
prepend one of the following types of character strings to
identify which symbology the data is using.
Symbology Identifier Options
Character
String
Description
AIM ISO/IEC
standard
The AIM Standard for symbology identifiers
consists of a three-character structure indicating
the symbology and the optional features of the
symbology. For more information about the AIM
Standard for symbology identifiers, refer to the
AIM ISO/IEC Standard.
User-defined
ASCII
The user-defined symbology identifier is one to
four ASCII characters in length. You can configure
character string user-defined symbology identifiers to assign
custom identifier strings to the bar code
symbologies.
Telepen
Enables or disables decoding of Telepen symbology. Telepen is
the only symbology to directly represent the full ASCII character
set without shift characters. It is extremely secure as it has
negligible risk of misreads and has a double density numeric
only mode.
Timeout Between Different Consecutive Codes
Use this command to invalidate a second bar code read that
occurs before the timeout expires. Use this command when
scanning bar codes that contain different data as opposed to the
Timeout Between Identical Consecutive Codes command that
you use when your bar codes contain identical data.
You can set Timeout Between Different Consecutive Codes to a
value from 0 to 2550 ms.
SF51 Cordless Scanner User’s Guide
45
Chapter 4 — Configuration Command Reference
Timeout Between Identical Consecutive Codes
Use this command to invalidate a second bar code read that
occurs before the timeout expires. Use this command when
scanning bar codes with identical data as opposed to the
Timeout Between Different Consecutive Codes command that
you use when your bar codes contain different data.
You can set Timeout Between Identical Consecutive Codes to a
value from 0 to 2550 ms.
Trigger Mode
Trigger mode allows you to set different types of triggering for
the scanner.
Trigger Mode Options
Mode
Description
Continuous/Edge
When you press the Scan button, the scanner
turns on and stays on. When you press the Scan
button a second time, the scanner turns off.
Simply releasing the button does not turn off the
scanner.
Level
When you press the Scan button, the red scanner
beam turns on and stays on until you release the
Scan button or until the SF51 successfully
decodes a bar code.
Pulse
Currently not supported.
Currently not supported.
Currently not supported.
Flashing
Autostand
Aim
Aim triggering allows you to turn on the scanner
and aim the red scanner beam without causing a
decode. Releasing the Scan button enables the
decode.
Note: EasySet contains a folder, predefined modes,
in Operating settings > trigger activation. The
commands in this folder are currently not supported
on the SF51.
46
SF51 Cordless Scanner User’s Guide
Chapter 4 — Configuration Command Reference
UPC/EAN
Enables or disables decoding of Universal Product Code
(UPC)/European Article Numbering (EAN) symbology.
UPC/EAN are fixed-length, numeric, continuous symbologies
that use four element widths. A scanner that is configured to
decode EAN bar codes can decode UPC, but the reverse is not
true. UPC code is a subset of EAN code.
ISBN
ISBN (International Standard Book Number) is a 10-digit
symbology that uniquely identifies books for tracking and
ordering.
With ISBN enabled, the first three characters (978) are ignored,
and the checksum is calculated on the remaining characters.
GTIN Processing
With GTIN (Global Trade Item Number) processing enabled,
two zeros are padded to the beginning of UPC-A, and one zero
is padded to the beginning of EAN-13 to expand the numbers to
14 digits. To use GTIN processing you also need to enable the
corresponding UPC/EAN symbology.
User Reset Factory Defaults
Causes the SF51 to perform a restart and restores all
configuration commands to their default settings, only if no
settings are locked. To reset all settings on the SF51, including
locked settings, use the Administrator Reset Factory Defaults
command. For more information, see “Administrator Reset
Factory Defaults” on page 36.
When you restore all configuration commands to their default
settings, you need to reestablish Bluetooth communications.
Vibrate Alert
Enables or disables the vibrate alert. When Vibrate Alert is
enabled, the scanner vibrates when you scan a valid bar code.
Vibrate Alert Duration
Sets the amount of time that the vibrate alert remains on. You
can set Vibrate Alert Duration to a value from 0 to 2550 ms.
SF51 Cordless Scanner User’s Guide
47
Chapter 4 — Configuration Command Reference
48
SF51 Cordless Scanner User’s Guide
Appendix
A
SF51 Cordless Scanner User’s Guide
49
Appendix A
Specifications
Use this section to find technical information about the SF51.
Physical Dimensions
Length:
Height:
Width:
15.7 cm (6.1 in)
3.4 cm (1.3 in)
4.6 cm (1.8 in) at the scanner, tapered
to 3.2 cm (1.26 in) at the handle
Weight:
263 g (9.3 oz)
Power and Electrical Specifications
Operating:
Rechargeable lithium-ion battery
Electrical rating:
x 5V; 1.5A
Temperature and Environmental Specifications
Operating:
-20°C to 50°C (-4°F to 122°F)
Storage:
-20°C to 60°C (-4°F to 140°F)
0°C to 45°C (32°F to 113°F)
0 to 95% non-condensing
Charging:
Relative humidity:
Environmental rating: IP52
Bar Code Symbologies
• Codabar
• MSI
• Codablock A
• Codablock F
• Code 11
• PDF417
• Plessey
• RSS 14
• Code 39
• RSS 14 Stacked
• RSS Limited
• RSS Expanded
• Standard 2 of 5
• Telepen
• Code 93/93i
• Code 128 / EAN 128
• Interleaved 2 of 5
• Matrix 2 of 5
• Micro PDF417
• UPC/EAN
50
SF51 Cordless Scanner User’s Guide
Appendix A
Note: PDF417 and Micro PDF417 are only available
on the SF51 with PDF version.
Bluetooth Radio
Radio Type:
Bluetooth Class 1 version 1.2
2.4 GHz
Frequency:
Radio Data Rate:
721 Kbits per second
Communication Range
Host radio Class 1:
30.5 m (100 ft)
Host radio Class 2:
Features:
10 m (32.8 ft)
Adaptive Frequency Hopping (ADF)
EV10 Scanner
Scan rate:
200 scans per second
up to 50 cm (19.7 in)
40 degrees
Scan range:
Scan angle:
Minimum X dimension: 4 mils (0.1 mm)
Accessories for the SF51
You can use these accessories (sold and ordered separately) with
the SF51. To order accessories, contact your local Intermec sales
representative.
Accessories for the SF51
Accessory
Description
1-Bay Charger
The 1-bay charger (P/N 074645) charges the
battery in the SF51 and is designed to be mounted
on a horizontal or vertical surface.
1-Bay Charger
Power Supply
The power supply for the 1-bay charger (P/N
074749) provides AC power to the 1-bay charger.
It comes with power supply adapters for Australia,
Continental Europe, United Kingdom, North
America, Central America, Mexico, and Japan. It
also comes with a flat plate for use with an AC
power cord. The AC power cord is not included.
SF51 Cordless Scanner User’s Guide
51
Appendix A
Accessories for the SF51 (continued)
Accessory
Description
4-Bay Charger
The 4-bay charger (P/N 074646) has the same
functionality of the 1-bay charger, except it allows
you to charge up to four SF51 scanners at the
same time.
4-Bay Charger
Power Supply
The power supply for the 4-bay charger (P/N
074935) provides AC power to the 4-bay charger.
USB Bluetooth The USB Bluetooth Adapter (P/N 074892)
Adapter
provides wireless communications to your host
computer and data collection application.
Forearm
Holster
The forearm holster (P/N 074649) provides you
with an easy way to carry the SF51 when you are
not using it. The holster supports either right-
handed or left-handed use.
Chest Strap
Holster
Use the chest strap holster (P/N 074648) to carry
the SF51 when you are not using it.
Industrial belt
clip holder
Use the belt clip (P/N 074811) to carry the SF51
when you are not using it.
52
SF51 Cordless Scanner User’s Guide
Index
I
SF51 Cordless Scanner User’s Guide
53
Index
Numbers
1-bay charger
accessory, described, 51
power supply, accessory, described, 51
4-bay charger
accessory, described, 52
power supply, accessory, described, 52
A
accessories, described, 51
Administrator Reset Factory Defaults
bar code, 25
command, 36
audio feedback, See beeps
B
bar code symbologies
Codabar, 39
Codablock A, 39
Codablock F, 39
Code 11, 39
Code 128 / EAN 128, 40
Code 39, 39
Code 93/93i, 40
Interleaved 2 of 5, 42
ISBT 128, 40
Matrix 2 of 5, 42
Micro PDF417, 42
MSI, 42
PDF417, 43
Plessey, 43
RSS 14, 44
RSS Expanded, 44
RSS Limited, 44
Standard 2 of 5, 44
Telepen, 45
UPC/EAN, 47
bar codes
scanning
how to, 8
troubleshooting, 27
setup sheet, described, 12
supported symbologies, 50
symbologies, default, 8
54
SF51 Cordless Scanner User’s Guide
Index
battery
charger
1-bay charger, described, 51
4-bay charger, described, 52
charging, 4
checking status, 4
using, 3
Beep Duration command, 36
Beep Frequency command, 36
Beep Volume command, 37
beeper, turning off, 7
beeps, understanding, 6
belt clip, accessory, described, 52
blue light, See Intermec Ready-to-Work indicator
Bluetooth
adapter
accessory, described, 52
installing, 18
communications
configuring, 15
host PC, connecting to, 18
troubleshooting, 25, 26
Connect/Disconnect command, 37
Device Name command, 37
Device Page command
described, 37
how to locate your SF51, 28
Discoverable command, 38
host devices supported, 16
PIN
command, 38
forgot, troubleshooting, 27
security, configuring, 15
Profile command, 38
radio
communication
configuring, 15
range, 51
specifications, 51
Security command, 38
SF51 Bluetooth address
how to get, 24
illustration, 17
Bluetooth Device Disconnect, bar code, 18
button, scan, illustration, 2
SF51 Cordless Scanner User’s Guide
55
Index
C
charger
1-bay charger, described, 51
4-bay charger, described, 52
charging, battery, 4
chest strap holster, accessory, described, 52
cleaning, scanner window, 29
Codabar command, 39
Codablock A command, 39
Codablock F command, 39
Code 11 command, 39
Code 128 / EAN 128 command, 40
GTIN Processing for EAN 128, 40
ISBT 128, 40
Code 39 command, 39
Code 93/93i command, 40
collecting data, how to, 9
commands, See configuration commands
communication range, Bluetooth radio, 51
computers, Bluetooth supported, 16
configuration commands
Administrator Reset Factory Defaults, 36
Beep Duration, 36
Beep Frequency, 36
Beep Volume, 37
Bluetooth Connect/Disconnect, 37
Bluetooth Device Name, 37
Bluetooth Device Page, 37
Bluetooth Discoverable, 38
Bluetooth PIN, 38
Bluetooth Profile, 38
Bluetooth Security, 38
Codabar, 39
Codablock A, 39
Codablock F, 39
Code 11, 39
Code 128 / EAN 128, 40
GTIN Processing for EAN 128, 40
ISBT 128, 40
Code 39, 39
Code 93/93i, 40
Configuration Modes and Utilities, 40
Consecutive Same Read Data Validation, 41
default values, 33 to 36
Disable All Symbologies, 41
Error Beep, 41
56
SF51 Cordless Scanner User’s Guide
Index
configuration commands (continued)
Good Read Beep Duration, 41
Good Read Beep Number, 41
Good Read Beep Timing, 42
Good Read LED Duration, 42
Interleaved 2 of 5, 42
ISBT 128, 40
Matrix 2 of 5, 42
Micro PDF417, 42
MSI, 42
PDF417, 43
Plessey, 43
Postamble, 43
Preamble, 43
RSS 14, 44
RSS Expanded, 44
RSS Limited, 44
Setup Beep, 44
Stacked Code Crackle, 44
Standard 2 of 5, 44
Symbology Identifier, 45
Telepen, 45
Timeout Between Different Consecutive Codes, 45
Timeout Between Identical Consecutive Codes, 46
Trigger Mode, 46
UPC/EAN, 47
GTIN processing, 47
ISBN, described, 47
User Reset Factory Defaults, 47
using to configure the SF51, 32
Vibrate Alert, 47
Vibrate Alert Duration, 47
Configuration Modes and Utilities
bar codes, 24
command, 40
configuring
Bluetooth communications, 15
from Intermec computer, 13
parameters, 12
security, 15
using EasySet, 12
connecting to a host device, 16
Consecutive Same Read Data Validation command, 41
D
data transmission settings, configuration commands, list of, 33
data, collecting, 9
SF51 Cordless Scanner User’s Guide
57
Index
default configuration
restoring, 14
values, 33 to 36
dimensions, physical, 50
Disable All Symbologies command, 41
disconnecting, how to, 18
discoverable state
described, 38
security, configuring, 16
E
EAN 128, GTIN processing, 40
EasySet
using to configure SF51
offline, 13
online, 12
where to download, 8
electrical specifications, 50
environmental specifications, 50
Error Beep command, 41
F
factory default settings, restoring, 14
firmware
upgrading, 19
version, how to get, 24
forearm holster, accessory, described, 52
forgot Bluetooth PIN, troubleshooting, 27
G
Get Product Version bar code, 24
Get SF51 Bluetooth Device Address bar code, 24
Get Sub-System Versions bar code, 24
Good Read
Beep
Duration command, 41
Number command, 41
Timing command, 42
LED Duration command, 42
green light, See status light
GTIN processing
EAN 128, 40
UPC/EAN, 47
H
help, calling Intermec, xi
holster, accessories, described, 52
humidity, specifications, 50
58
SF51 Cordless Scanner User’s Guide
Index
I
Interleaved 2 of 5 command, 42
Intermec
computer
connecting to, 17
supported, 16
using to configure SF51, 13
contact information, ii
Ready-to-Work indicator
described, 6
illustration, 5
telephone support, xi
ISBT 128 command, 40
L
.ldr, firmware upgrade file, 19
labels, bar code, scanning, 8
lights
blue, See Intermec Ready-to-Work indicator
Intermec Ready-to-Work indicator, described, 6
status, described, 5
understanding, 4
limited discoverable
bar code, 16
described, 38
M
Macro PDF417, described, 43
magnetic connector, illustration, 2
Matrix 2 of 5 command, 42
Micro PDF417 command, 42
MSI command, 42
O
off, turning off the SF51, 3
on, turning on the SF51, 3
operating settings, list of, 35
operating the SF51
humidity range, 50
temperature range, 50
P
paging the SF51, how to, 28
parameters, configuring SF51, 12
PDF417 command, 43
physical
dimensions, 50
specifications, 50
SF51 Cordless Scanner User’s Guide
59
Index
Plessey command, 43
Postamble command, 43
power down bar code, 3
power specifications, 50
power supply
1-bay charger, accessory, described, 51
4-bay charger, accessory, described, 52
Preamble command, 43
problems, finding and solving, 25
product version, how to get, 24
R
radio
communications, configuring, 15
specifications, 51
Ready-to-Work indicator
described, 6
illustration, 5
red light, See status light
resetting, SF51, 28
restoring default settings, 14
RSS 14 command, 44
RSS Expanded command, 44
RSS Limited command, 44
S
Scan button
illustration, 2
troubleshooting, 27
scanner, See SF51
scanner window, cleaning, 29
scanning
bar codes
described, 8
how to hold the SF51, 9
troubleshooting, 27
security
Bluetooth PIN, 15
configuring, 15
discoverable state, 16
Serial port profile, Bluetooth
configuring, 38
described, 15
disconnecting, 18
resetting the SF51, 29
settings, restoring default, 14
Setup Beep command, 44
60
SF51 Cordless Scanner User’s Guide
Index
SF51
Bluetooth address
how to get, 24
illustration, 17
cleaning, 29
configuring, 12
connecting to a host device, 16
description, 2
firmware version, how to get, 24
how to turn on, 3
locating using Bluetooth Device Page command, 28
paging using Bluetooth Device Page command, 28
product version, how to get, 24
resetting, 28
scan engine, specifications, 51
sub-system version, how to get, 24
troubleshooting, 24
turning off, 3
turning on, 3
upgrading, 19
using to scan bar codes, 8
with PDF version
bar code symbologies supported, 51
default bar code symbologies, 8
sounds, See beeps
specifications
electrical, 50
humidity, 50
power, 50
radio, Bluetooth, 51
scan engine, 51
temperature, 50
SPP, See Serial port profile
Stacked Code Crackle command, 44
Standard 2 of 5 command, 44
status
beeps, 6
checking battery, 4
light
described, 5
illustration, 5
sub-system version, how to get, 24
support, calling Intermec, xi
SF51 Cordless Scanner User’s Guide
61
Index
symbologies, bar code
default, 8
list of, 34
supported, 50
Symbology Identifier command, 45
T
Telepen command, 45
temperature, specifications, 50
Timeout Between Different Consecutive Codes command, 45
Timeout Between Identical Consecutive Codes command, 46
Trigger Mode command, 46
troubleshooting
Bluetooth PIN, forgot, 27
cannot establish a Bluetooth connection, 25, 26
guide to finding problems, 25
lost Bluetooth connection, 25
resetting the SF51, 28
Scan button, 27
scanning, 27
using Configuration Modes and Utilities, 24
turning off the SF51, 3
turning on the SF51, 3
U
understanding
beeps, 6
lights, 4
UPC/EAN command, 47
GTIN processing, 47
ISBN, 47
upgrading, SF51, 19
USB Bluetooth adapter, See Bluetooth adapter
User Reset Factory Defaults command, 47
V, W
Vibrate Alert
command, described, 47
described, 7
turning off, 7
turning on, 7
Vibrate Alert Duration command, 47
volume, adjusting, 37
wireless communications, configuring, 15
62
SF51 Cordless Scanner User’s Guide
Index
SF51 Cordless Scanner User’s Guide
63
Corporate Headquarters
6001 36th Avenue West
Everett, Washington 98203
U.S.A.
tel 425.348.2600
fax 425.355.9551
SF51 Cordless Scanner User's Guide
*074474-003*
P/N 074474-003
|