Jacuzzi Landscape Lighting GQ99000 User Manual

Chromatherapy Light Kit  
instaLLation and operation instruCtions  
The Jacuzzi Chromatherapy Lamp provides beautiful and  
pLanning instaLLation  
practical illumination to your bath. It includes vivid rotating colors  
or penetrating white lighting to enhance your Jacuzzi experience,  
and is built to give years of service and pleasure.  
It is necessary to plan the location of the control box, control  
panel, and each lamp before drilling any holes. A possible  
configuration of the Chromatherapy equipment is shown in  
Figure 1.  
The Lamp can be installed on most Jacuzzi baths or on any  
bath having sufficient flat space on the bath shell. The basic kit  
consists of an electrical control box and one Chromatherapy  
Lamp, with all necessary modular cables. The control box can  
support up to four lamps. An additional lamp kit is available and  
provides one lamp and one cable.  
First, consider the location requirements for the control panel and  
lamp(s), see Figure 2. The control panel cannot be immersed  
in the bath water. Therefore it must be positioned at least one  
inch above the level of the overflow drain. On the other hand,  
the lamp(s) must be positioned a minimum of 4 inches below the  
normal water line.  
The installation requires drilling a hole in the bath shell for the  
control panel and each lamp. The Installation and Operation  
Instructions will provide all the information required for planning  
the installation, completing the installation, and complete  
operation of the equipment. The control box must be installed  
meeting applicable local building and electrical codes on a stud  
beam or wall.  
Control panel  
Lamp 1  
Lamp 2  
Contents  
Basic Lamp Kit . . . . . . . . . . . . . . . . . . . . . . 1  
Planning Installation . . . . . . . . . . . . . . . . . . . 1  
Control Panel . . . . . . . . . . . . . . . . . . . . . 2  
Chromatherapy Lamp . . . . . . . . . . . . . . . . 2  
Mount the Control Box . . . . . . . . . . . . . . . . . . 3  
Drill the Holes . . . . . . . . . . . . . . . . . . . . . . 3  
Drill Hole for Control Panel . . . . . . . . . . . . . . 3  
Drill Hole for Lamp(s) . . . . . . . . . . . . . . . . . 3  
Install Panel and Lamp(s) . . . . . . . . . . . . . . . . 4  
Mount Control Panel . . . . . . . . . . . . . . . . . 4  
Mount Chromatherapy Lamp(s) . . . . . . . . . . . 4  
Leak Test . . . . . . . . . . . . . . . . . . . . . . . . 5  
Operate Chromatherapy Lighting . . . . . . . . . . . . 5  
Use Chromatherapy Lighting . . . . . . . . . . . . . 5  
Control Chromatherapy Lighting . . . . . . . . . . . 5  
Control Color Lighting . . . . . . . . . . . . . . . 5  
Control White Lighting . . . . . . . . . . . . . . 5  
Figure 1. Possible configuation for Chromatherapy assembly  
Top rim of bath  
Hole for control panel  
1 inch  
Overflow drain  
Normal water line  
BasiC Lamp Kits  
GD56000 Complete kit  
One control box for wall mounting  
One control panel and one control cable (RJ-45 plug)  
One lamp and one lamp cable (RJ-11 plug)  
4 inches (minimum)  
GQ88000 Accessory lamp kit  
One lamp and one lamp cable (RJ-11 plug)  
Hole for lamp(s)  
To add an additional lamp, up to four total, order the accessory  
lamp kit. It includes one lamp and one lamp cable. Each lamp  
is mounted in the same manner, and is connected to the control  
box as described. To order additional lamps, please contact your  
Jacuzzi dealer or agent.  
Floor of bath  
important: Read the instructions before beginning the  
installation.  
Figure 2. Locate the Holes for Control Panel and Lens(es)  
Copyright © 2008 by Jacuzzi Whirlpool Bath Products  
GQ99000 • 07-08  
 
No. 10 Screw hole  
(2 both sides)  
mount the ControL Box  
Mount the control box to a stud beam or secure wall using four  
No. 10 screws, or four No. 20, 1/4 inch screws. The mounting  
holes for the screws are shown in Figure 5.  
No. 20, 1/4”  
Screw hole  
(2 both sides)  
note: The modular plugs are also shown in the figure. Position  
the control box in the most advantageous way, considering the  
length and direction of the modular cables.  
Caution: The power cable must be connected to a dedicated  
ground fault circuit interruptor (GFCI). No other outlet is  
acceptable to this equipment.  
Attach the control box securely to the mounting location.  
driLL the hoLes  
Modular plug  
for control panel  
Modular plugs  
for lamps (1 to 4)  
3-Prong power cable  
After preparation of the bath shell for drilling the hole for the  
control panel and each Chromatherapy lamp, proceed with drilling  
the holes. This should be completed by a technican experienced  
in drilling through a fine acrylic material.  
Figure 5. Control Box Connections  
The areas of the holes have been covered with masking tape and  
carefully outlined to indicate the location and size of the holes.  
The tape will help prevent chipping of the acrylic.  
Drill Hole for the Control Panel  
The control panel has been located a minimum of one inch  
above the level of the overflow drain. It has been marked for a  
1-1/16 inch diameter with a 5/32 inch notch at the right center, see  
Figure 3.  
Caution: Drill the holes from the inside of the unit carefully  
to prevent chipping or cracking of the acrylic shell. Use a drill  
guide for best results and begin drilling at low speed until the  
drill penetrates the acrylic layer, then use a high speed for the  
remaining material.  
1.  
2.  
First use a 5/32 inch drill bit to carefully drill the notch.  
Use the 5/32 inch drill bit to drill a pilot hole for the  
1-5/8 inch hole.  
3.  
4.  
Use a 1-1/16 inch drill bit to complete the hole for the lamp.  
Remove any and all burrs or roughness from the inside of  
the hole.  
Drill Hole for the Lamp(s)  
The lamp(s) has been located a minimum of 4 inches below the  
normal water level. It has been marked for a 1-5/8 inch diameter,  
see Figure 4.  
Caution: Drill the holes from the inside of the unit carefully  
to prevent chipping or cracking of the acrylic shell. Use a drill  
guide for best results and begin drilling at low speed until the  
drill penetrates the acrylic layer, then use a high speed for the  
remaining material.  
1.  
Use the 5/32 inch drill bit to drill a pilot hole for the 1-1/16  
inch hole.  
2.  
Use a 1-5/8 inch drill bit to complete the hole for the control  
panel.  
Jacuzzi© Chromatherapy: Installation and Operation  
Page ꢀ of 5  
GQ99000 • 07-08  
 
3.  
Remove any and all burrs or roughness from the inside of  
the hole.  
Apply silicone  
behind panel  
Clean away all debris and tools from the area. Use a moist cotton  
cloth to wipe the inside and shelf of the bath rim.  
Modular  
cable  
INSTALL PANEL AND LAMP(S)  
Install the control panel and each lamp as described below.  
Control  
panel  
Hole for control panel  
(see detail below)  
Mount Control Panel  
The hole for the control panel has a notch to ensure proper  
mounting alignment of the control panel on the bath, see Figure 6.  
Figure 6. Mount the Control Panel  
1.  
Apply clear silicone to the back side of the control panel and  
insert the panel into place.  
Caution: Do not permit silicone to enter the plug area at the  
back of the panel. Failure to comply may result in damage to the  
equipment.  
Bath shell (Outisde of bath)  
2.  
Press the panel fast against the inside surface of the bath.  
Make sure the panel is pressed completely against the  
shell.  
3.  
Remove excess silicone from around the control panel.  
Chromatherapy  
lamp or control  
panel (Inside of  
bath)  
4.  
Alow the silicone to cure to ten to fifteen minutes  
undisturbed.  
Plug from control  
panel or lamp  
5.  
Attach the control cable from the control panel to the control  
box, see Figure 7. The proper plug for the control panel is  
shown in Figure 5.  
Mount Chromatherapy Lamp(s)  
The hole is ready to mount the lamp(s), see Figure 8.  
Figure 7. Attach plug to Chromatherapy device  
1.  
Remove the retainer nut from the lamp assembly.  
2.  
Apply clear silicone around the back of the edge of the  
lamp.  
Apply silicone  
behind panel  
Hole,  
1-1/16”  
Retainer  
nut  
Caution: Do not permit silicone to enter the plug area at the  
back of the lamp. Failure to comply may result in damage to the  
equipment.  
3.  
Insert the lamp housing through the hole in the bath shell  
so that the edge of the lamp housing is tightly against the  
inside surface of the bath. Make sure the lamp is pressed  
completely against the shell to prevent leakage.  
Inside surface  
of bath shell  
4.  
From the outside of the bath shell, screw the retainer nut  
over the threaded body, as shown in the figure. Hand-  
tighten the retainer nut onto the lens threads. Do not permit  
the lamp to rotate while tightening the retainer nut.  
Lamp  
assembly  
Figure 8. Hole for Chromatherapy Lamp(s)  
5.  
6.  
7.  
Remove any excess silicone from around the lamp.  
Allow the silicone to cure for ten to fifteen minutes.  
Attach the light cable from the back of the lamp to the  
control box see Figure 7. The proper plug for the lamp(s) is  
shown in Figure 5.  
note: There are four plugs for up to four lamp cables. Any of the  
four plugs can be used for proper operation. Jacuzzi recommends  
that you start with the left-most plug, closest to the control box  
cable plug to attach each lamp.  
Jacuzzi© Chromatherapy: Installation and Operation  
Page ꢁ of 5  
GQ99000 • 07-08  
 
LeaK test  
Allow the silicone to cure for 24 hours before performing the Leak  
Test. Fill the bath with water and check for leakage at the lamp  
location(s).  
operate Chromatherapy Lighting  
The Chromatherapy Control Panel is located for easy access  
while using the bath, see Figure 8. It is controlled by a three-  
button panel. The three button panel controls the Light Switch  
(center button), and two arrow keys (the Up Arrow and the Down  
Arrow), see Figure 9.  
Figure 9. Chromatherapy Control Panel  
Use Chromatherapy Lighting  
1. Press the Control Panel Light Switch to initiate the  
Chromatherapy Lighting. The color that shines is the last  
color that was on when the Chromatherapy Lighting was  
turned off (Programmed Color).  
2. Press the Light Switch again to initiate the simple White  
Lighting.  
3. Press the Light Switch a third time to turn off the  
Chromatherapy Lighting.  
Control Chromatherapy Lighting  
The use of the arrow keys provides beautiful and useful options  
for the lighting.  
ControL CoLor Lighting  
When you initiate the Chromatherapy Lighting, the Programmed  
Color will shine. Use the Up Arrow to initiate cycling through the  
colors. The scrolling through the wonderful colors indeed provides  
a "chromatherapeutic" effect.  
note: The color cycle is: Orange, red, pink, violet, blue, green,  
yellow, and orange again. (If you use the Down Arrow, the color  
cycling will follow the reverse order through the colors.)  
If you want to stop at a particular color, simply use the Up Arrow  
again to stop the cycling.  
ControL White Lighting  
In the White Lighting setting there are two positions for a brighter  
light, controlled by the Up Arrow; and two positions for the dimmer  
light, using the Down Arrow.  
Jacuzzi© Chromatherapy: Installation and Operation  
Page 5 of 5  
GQ99000 • 07-08  
 

Insignia Flat Panel Television NS LCD26F NS LCD32F NS CL26C User Manual
Intellinet Network Solutions Network Router 523240 User Manual
John Lewis Refrigerator JLUCLFW6003 User Manual
JVC Home Theater System SP PWA55 User Manual
JVC Speaker System SP UXG70 User Manual
Kenwood Marine Radio TS 480HX User Manual
Kidde Carbon Monoxide Alarm KN COB DP H User Manual
Kodak Digital Camera CD913 User Manual
Konica Minolta Digital Camera 2430DL User Manual
Konica Minolta Oxygen Equipment PULSOX 300 User Manual