KitchenAid Cooktop xgcd807x User Manual

30" (76.2 CM) GAS DOWNDRAFT COOKTOP  
PRODUCT MODEL NUMBERS  
CUTOUT DIMENSIONS  
KGCD807X  
B
A
C
GAS SUPPLY REQUIREMENTS  
Type of Gas  
Natural Gas:  
D
This cooktop is design-certified by CSA International for use with Natural gas or,  
after proper conversion, for use with LP gas.  
E
F
This cooktop is factory set for use with Natural gas. If converting to LP gas, see  
H
the “LP Gas Conversion” instructions provided in the package containing  
literature. The model/serial rating plate located on the underside of the cooktop  
base has information on the types of gas that can be used. If the types of gas  
listed do not include the type of gas available, check with the local gas supplier.  
I
LP Gas Conversion:  
Conversion must be done by a qualified service technician.  
J
G
No attempt shall be made to convert the cooktop from the gas specified on the  
model/serial rating plate for use with a different gas without consulting the  
serving gas supplier. See the Gas Conversion instructions provided in the  
package containing literature.  
Gas Supply Line  
A. 28⁵⁄₈" (72.7 cm) maximum  
B. 19¹⁵⁄₁₆" (50.6 cm) maximum  
C. 9⁵⁄₁₆" (21.6 cm)  
D. 6⁴⁹⁄₆₄" (17.2 cm)  
E. 2¹⁄₈" (5.4 cm) minimum space to front edge of cooktop  
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the cooktop location. A  
smaller size pipe on longer runs may result in insufficient gas supply. Pipe-joint  
compounds that resist the action of LP gas must be used. Do not use TEFLON®†  
tape. With LP gas, piping or tubing size should be ¹⁄₂" minimum. Usually, LP  
gas suppliers determine the size and materials used in the system.  
F. Floor exhaust option  
G. 6¹⁄₈" (15.6 cm) for 6" (15.2 cm) vent system and 5¹⁄₈" (13.1 cm) for  
Flexible metal appliance connector:  
5" (12.7 cm) vent system  
If local codes permit, use a ¹⁄₂" or ³⁄₄" I.D. flexible stainless steel tubing gas  
H. 9⁵⁄₁₆" (21.6 cm)  
I. 13³⁄₈" (33.9 cm) from the top of the countertop surface  
J. Wall exhaust option  
connector, designed by CSA to connect the cooktop to the rigid gas supply  
line.  
PRODUCT DIMENSIONS  
Rigid pipe connection:  
30" (76.2 cm) Cooktop  
The rigid pipe connection requires a combination of pipe fittings to obtain an in-  
line connection to the cooktop. The rigid pipe must be level with the cooktop  
connection. All strains must be removed from the supply and fuel lines so  
cooktop will be level and in line.  
A
B
Must include a shutoff valve:  
The supply line must be equipped with a manual shutoff valve. This valve  
should be located in the same room but external to the cooktop opening, such  
as an adjacent cabinet. It must be accessible without removing the cooktop,  
and it should be in a location that allows ease of opening and closing. Do not  
block access to shutoff valve. The valve is for turning on or shutting off gas to  
the cooktop.  
C
A. 21³⁷⁄₆" (54.8 cm) with stainless steel trim or  
21½" (54.6 cm) without stainless steel trim  
B. 19⁴⁷⁄₆₄" (50.1 cm) screw head to screw head  
C. Model/serial rating/clearance plate location  
B
A
C
A. Gas supply line  
B. Shutoff valve “open” position  
C. To cooktop  
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.  
Page 1 of 2  
Ref. W10526087A  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
5/6/13  
 

Intel Personal Computer ESM 2740 User Manual
Intel Switch SRW224P User Manual
Jenn Air Oven JJW2330 User Manual
Jenn Air Refrigerator JS48PPFXDA User Manual
John Lewis Ventilation Hood JLBIHD601 User Manual
JVC CD Player KS FX480J User Manual
JVC Speaker System AX UXG6 User Manual
JVC Speaker System MX J333VU User Manual
Kenwood Speaker KFC6965S User Manual
Kramer Electronics Stereo Amplifier VM 5ARII User Manual