Kramer Electronics, Ltd.
USER MANUAL
Model:
TP-330FW
FireWire Range Extender/ HUB
Introduction
1
Introduction
Welcome to Kramer Electronics! Since 1981, Kramer Electronics has been
providing a world of unique, creative, and affordable solutions to the vast range of
problems that confront the video, audio, presentation, and broadcasting
professional on a daily basis. In recent years, we have redesigned and upgraded
most of our line, making the best even better! Our 1,000-plus different models now
Congratulations on purchasing your Kramer TOOLS TP-330FW FireWire Range
Extender/HUB which is ideal for:
•
•
Digital video production, editing studios and digital video live broadcasting
PC FireWire port extensions and long cable drivers
The package includes the following items:
•
•
•
•
TP-330FW FireWire Range Extender/HUB
Power adapter (12V DC output)
This user manual2
Mounting bracket
2
Getting Started
We recommend that you:
•
Unpack the equipment carefully and save the original box and packaging
materials for possible future shipment
•
•
Review the contents of this user manual
Use Kramer high performance, high resolution cables3
1 GROUP 1: Distribution Amplifiers; GROUP 2: Switchers and Matrix Switchers; GROUP 3: Control Systems; GROUP 4:
Format/Standards Converters; GROUP 5: Range Extenders and Repeaters; GROUP 6: Specialty AV Products; GROUP 7: Scan
Converters and Scalers; GROUP 8: Cables and Connectors; GROUP 9: Room Connectivity; GROUP 10: Accessories and Rack
Adapters; GROUP 11: Sierra Products
2 Download up-to-date Kramer user manuals from http://www.kramerelectronics.com
3 The complete list of Kramer cables is available from http://www.kramerelectronics.com
1
Overview
3
Overview
The high quality Kramer TOOLS™ TP-330FW FireWire Range Extender/HUB
is a truly unique product that lets you extend the standard 4.5m (13.5ft) FireWire
inexpensive TP cable.
The TP-330FW FireWire Range Extender/HUB is based on FireWire which:
•
digital video, audio and data, and computer hardware items2
•
•
Is simple to use and operates independently of the host system
applications
In particular, the TP-330FW:
•
•
•
Supports the provisions of the IEEE 1394a-2000 and 1394-1995 Standard for
High Performance 1394 Serial Bus up to 400Mbps
Enables 1394 400Mbps signals to be transmitted and received over extended
distances on twisted pair cable
suppressing all transient high voltages to allowed levels
To achieve the best performance:
•
Avoid interference from neighboring electrical appliances that may adversely
influence signal quality
•
Position your TP-330FW away from moisture, excessive sunlight, and dust
3.1
Shielded Twisted Pair and Unshielded Twisted Pair
Standard STP or UTP cable should be used. Do not use skew-free cable.
Although Unshielded Twisted Pair (UTP) cable might be preferred for long range
applications, UTP cable should be installed as far as possible from electric cables,
motors, and so on, as these devices tend to create electromagnetic interference.
However, since the use of UTP cable might not conform to electromagnetic
standards, Kramer does not commit to meeting the standard with UTP cable.
1 Originally developed by Apple™ and published as IEEE 1394 by the Institute of Electrical and Electronics Engineers
2 Hardware items include digital cameras, computers, printers, VCRs, CD-ROMs, hard disks, scanners, and graphic cards
3 When a device is added or removed, the 1394 bus re-enumerates and configures automatically
4 You can connect and disconnect inputs and outputs dynamically, without having to restart the PC or cycle power
5 Video/audio applications require constant transfer rates, which the serial bus provides by supporting isochronous transfers
6 Often when connecting a "live" DV source to a receptor, an electrical potential difference or any other element creating a high voltage
(such as ESD or a live chassis) may permanently damage one or both of the connected devices. This high voltage may be seen as a spark
occurring at the instant of connection, or may not be seen at all, but nevertheless can result in costly damage
3
Overview
3.2
3.3
About the Power Connect™ Feature
The Power Connect™ feature here means that only one unit in a system, the
transmitter or receiver, needs to be connected to a power source when the devices
are within 50m (164ft) of each other. The Power Connect™ feature applies as long
as the cable can carry power and the distance does not exceed 50m on standard
Recommendations for Achieving the Best Performance
To achieve the best performance:
Connect only good quality connection cables, thus avoiding interference,
deterioration in signal quality due to poor matching and elevated noise-levels
(often associated with low quality cables)
Avoid interference from neighboring electrical appliances and position your
TP-330FW away from moisture, excessive sunlight and dust
1 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances
KRAMER: SIMPLE CREATIVE TECHNOLOGY
4
Defining the TP-330FW FireWire Range Extender/Hub
4
Defining the TP-330FW FireWire Range Extender/Hub
Figure 1: TP-330FW FireWire Range Extender/Hub Front and Rear Panels
Table 1: TP-330FW FireWire Range Extender/Hub Front and Rear Panel Features
#
Feature
Function
1
FW PORT 1
FW PORT 2
CAT 5 LINK LED
ON LED
Connect to the FireWire device
Connect to the FireWire device
2
3
4
5
Lights green when the TP link is established
Lights green when the unit is powered on
CAT 5 PORT
12V DC
Connect to the CAT 5 PORT on the second TP330FW via STP cable
Connect to +12V DC power adapter, center pin positive
1 Only one FireWire device can be active at a time
5
Connecting FireWire Devices via Two TP-330FW Units
5
Connecting FireWire Devices via Two TP-330FW Units
To connect two FireWire devices via two TP-330FW units over an extended
Figure 2: Connecting FireWire Devices via Two TP-330FW Units
1. On the first TP-330FW connect the FireWire device (for example, a video
camcorder) to FW PORT 1 or FW PORT 2.
2. On the second TP-330FW connect the FireWire device (for example, a
computer workstation) to FW PORT 1 or FW PORT 2.
3. Connect the two TP-330FW units together via the CAT 5 PORTs on the rear
panel using STP/UTP cable with a maximum length of 100m (328ft).
4. Connect the first 12V DC power adapter to the first TP-330FW and to the
mains supply.
5. If more than 50m (164ft) away from the first TP-330FW—connect the
second 12V DC power adapter to the second TP-330FW and to the mains
supply.
KRAMER: SIMPLE CREATIVE TECHNOLOGY
6
Wiring the TP LINE IN/LINE OUT RJ-45 Connectors
On both TP-330FW units:
.
The ON LEDs light green indicating that they are receiving power
—and—
.
The CAT 5 LINK LEDs light green indicating that a CAT 5 link has been
established between the units
Notes:
•
•
•
You can connect two FireWire devices simultaneously to a TP-330FW,
however, only one device can be active at a time
There is no need to install the Kramer PT-1FW DV Line Protector on the
STP/UTP as the TP-330FW already contains built-in line protection
You can connect devices with 1394b (FireWire 800) bilingual interfaces at
speeds of up to 400Mbps. The FireWire cable used must have a bilingual
connector on one side and a 1394a 6-pin connector on the other side
6
Wiring the TP LINE IN/LINE OUT RJ-45 Connectors
EIA/TIA 568B wiring. When using STP cable, connect/solder the cable shield to
the RJ-45 connector shield.
Table 2: Twisted Pair Cable Wiring
PIN
Wire Color
Green/White
PIN
1
2
3
4
5
6
7
8
7
8
3
4
5
6
1
2
Green
Orange/White
Blue
Blue/White
Orange
Brown/White
Brown
12345678
12 45 78
36
Figure 3: UTP Connector
7
Technical Specifications
7
Technical Specifications
PORTS:
2 FireWire ports on 6-circuit FireWire 400 connectors
1 STP/UTP port on an RJ-45 connector
TRANSFER RATE:
400Mbps
IEEE-1394 STANDARDS:
ESD LINE PROTECTION:
IEEE 1394a-2000, IEEE 1394-1995 @ up to 400Mpbs
IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact), IEC 61000-4-5 (Lightning) 12A (8/20us),
and IEC 61000-4-4 (EFT) 40A (5/50ns)
POWER SOURCE:
DIMENSIONS:
WEIGHT:
12 VDC, 60mA
12cm x 6.9cm x 2.4cm (4.7" x 2.7" x 0.9") W, D, H
0.4kg (0.9lbs) approx.
ACCESSORIES:
Power supply, mounting bracket
1 Specifications are subject to change without notice
KRAMER: SIMPLE CREATIVE TECHNOLOGY
8
LIMITED WARRANTY
We warrant this product free from defects in materialand workmanship under the following terms.
HOW LONG IS THE WARRANTY
Labor and parts are warranted for seven years from the date of the first customer purchase.
WHO IS PROTECTED?
Only the first purchase customer may enforce this warranty.
WHATIS COVEREDANDWHATIS NOT COVERED
Except as below, this warranty covers all defects in material or workmanship in this product. The following are not
covered by thewarranty:
1. Any product which is not distributed by us or which is not purchased from an authorized Kramer dealer. If you are
uncertain as to whether a dealer is authorized, please contact Kramer at one of the agents listed in the Web site
2. Any product, on which the serial number has been defaced, modified or removed, or on which the WARRANTY VOID
IF TAMPERED sticker has been torn, reattached, removed or otherwise interfered with.
3. Damage, deterioration ormalfunctionresultingfrom:
i) Accident, misuse, abuse, neglect, fire, water, lightningorotheracts of nature
ii) Product modification, orfailure to follow instructions supplied withtheproduct
iii) Repair orattemptedrepairby anyone not authorized by Kramer
iv) Any shipment of theproduct (claims must bepresentedtothe carrier)
v) Removal orinstallation of theproduct
vi) Any other cause, which does not relate to aproduct defect
vii) Cartons, equipment enclosures, cables or accessories used inconjunction withtheproduct
WHATWE WILLPAYFORANDWHATWE WILLNOT PAY FOR
We will pay labor andmaterialexpenses for covered items. We willnot pay for the following:
1. Removalor installations charges.
2. Costs of initial technical adjustments (set-up), including adjustment of user controls or programming. These costs are
theresponsibility of the Kramer dealer from whom theproduct was purchased.
3. Shipping charges.
HOW YOU CAN GET WARRANTY SERVICE
1. To obtain service on you product, you must take or ship it prepaid to any authorized Kramer service center.
2. Whenever warranty service is required, the original dated invoice (or a copy) must be presented as proof of
warranty coverage, and should be included in any shipment of the product. Please also include in any mailing a
contact name, company, address, and a description of the problem(s).
3. For the name of the nearest Kramer authorized service center, consult your authorized dealer.
LIMITATIONOFIMPLIEDWARRANTIES
All implied warranties, including warranties of merchantability and fitness for a particular purpose, are limited in duration
to the length of this warranty.
EXCLUSIONOF DAMAGES
The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option. Kramer
shallnot be liable for:
1. Damage to other property caused by defects in this product, damages based upon inconvenience, loss of use of the
product, loss of time, commercialloss; or:
2. Any other damages, whether incidental, consequential or otherwise. Some countries may not allow limitations on
how long an implied warranty lasts and/or do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitations and exclusions may not apply to you.
This warranty gives you specific legal rights, andyou may also have otherrights, which vary from place toplace.
NOTE:Allproducts returned to Kramerforservice must haveprior approval.This may beobtained from your dealer.
This equipment has been tested to determine compliancewiththerequirements of:
EN-50081:
"Electromagnetic compatibility (EMC);
generic emission standard.
Part 1: Residential, commercialand light industry"
"Electromagnetic compatibility (EMC) generic immunity standard.
Part 1: Residential, commercialand light industry environment".
FCC* Rules and Regulations:
EN-50082:
CFR-47:
Part 15: “Radio frequency devices
Subpart B Unintentional radiators”
CAUTION!
Servicing the machines can only be done by an authorized Kramer technician. Any user who makes changes or
modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the
equipment.
Use the suppliedDC powersupply to feedpower to the machine.
Pleaseuse recommendedinterconnectioncables toconnect the machine to othercomponents.
* FCC andCEapprovedusing STPcable(for twisted pair products)
9
For the latest information on our products and a list of Kramer
distributors, visit our Web site www.kramerelectronics.com
where updates to this user manual may be found.
We welcome your questions, comments and feedback.
Safety Warning:
Disconnect the unit from the power supply
before opening/servicing.
Caution
Kramer Electronics, Ltd.
E-mail: [email protected]
P/N: 2900-000624 REV 2
|