La Crosse Technology Weather Radio WS 7034U User Manual

WS-7034U  
Wireless 433 MHz  
Temperature Station  
Instruction Manual  
 
QUICK SETUP  
Hint: Use good quality Alkaline  
Batteries and avoid rechargeable  
batteries.  
1. Have the indoor temperature station  
and remote temperature sensor 3 to  
5 feet apart.  
2. Batteries should be out of both  
units for 10 minutes.  
3. Place the batteries into the remote  
temperature sensor first then into  
the indoor temperature station.  
(All remote temperature sensors must be  
started before the indoor temperature  
station)  
4. DO NOT PRESS ANY BUTTONS  
FOR 10 MINUTES.  
3
 
In this time the indoor temperature  
station and remote temperature sensor  
will start to talk to each other and the  
display will show both the indoor  
temperature and an outdoor temperature.  
If the indoor temperature station does  
not display both temperatures after the  
10 minutes please retry the set up as  
stated above. After both indoor and  
outdoor temperatures are displayed for  
10 minutes you can place your remote  
temperature sensor outdoors and set  
your time.  
The remote temperature sensor should  
be placed in a dry, shaded area. The  
remote temperature sensor has a range  
of 80 feet. Any walls that the signal  
will have to pass through will reduce  
distance. An outdoor wall or window  
will have 20 to 30 feet of resistance and  
an interior wall will have 10 to 20 feet  
4
 
of resistance. Your distance plus  
resistance should not exceed 80 ft. in a  
straight line.  
NOTE: Fog and mist will not harm  
your remote temperature sensor but  
direct rain must be avoided.  
To complete the set up of your indoor  
temperature station after the 10 minutes  
have passed please follow the steps on  
pages 8-9.  
5
 
INVENTORY OF CONTENTS  
1. The indoor temperature station (Figure  
1)  
2. The remote temperature sensor (TX6U)  
and mounting bracket. (Figure 2)  
3. 3 each, 1/2” Philips screws.  
4. One strip of double sided adhesive tape.  
5. Instruction Manual and Warranty Card.  
Figure 1  
Holder  
Figure 2  
6
 
ADDITIONAL EQUIPMENT  
(not included)  
1. 1 Philips screwdriver.  
2. 2 Fresh AAA Alkaline batteries.  
3. 2 Fresh AA Alkaline batteries  
7
 
DETAILED SETUP GUIDE  
Battery Installation  
1. Install 2 AA  
batteries in the  
remote temperature  
sensor. Make sure  
they do not spring  
free, or start-up  
problems may occur.  
2.  
Install 2 AAA  
batteries in the  
indoor temperature  
station. Do not  
press any buttons  
for at least ten  
minutes.  
Battery  
Cover  
Setting the Time  
8
 
1. Press and hold the  
SET” button for 5  
second, “12h” will  
appear in the TIME  
LCD.  
2. Press and release the “MIN/MAX”  
button to select either 12h time  
(am/pm) or 24h time  
3. Press and release the “SET” button 2  
times, the hour will flash in the upper  
left corner.  
4. Press and release the “MIN/MAX”  
button to set the hours  
5. Press and release the “SET” button to  
move to the minute setting  
6. Press and release the “MIN/MAX”  
button to set the minutes.  
7. Press and release the “SET” button to  
activate the clock.  
Note: When in 12h mode, there is only a  
“PM” display, which appears under “TIME.”  
If there is no display here it is AM. Make  
sure you set the time accordingly.  
9
 
Selecting Units of Measurement  
1. Press and hold the “SET” button for 5  
second until “12h” or “24h” appears  
in the TIME LCD.  
2. Press and release the “SET” button  
again, “°F” will appear in the TIME  
LCD.  
3. Press and release the “MIN/MAX”  
button to shift between °F and °C.  
4. Press and release the “SET” button  
twice to activate settings.  
10  
 
FEATURES  
Minimum and Maximum Temperatures  
1. Press and release the “MIN/MAX”  
button, “MIN” appears next to the  
indoor and remote temperatures.  
2. The recorded minimum temperature is  
displayed. The time of the minimum  
outdoor temperature will also flash.  
3. Press the “MIN/MAX” button,  
“MAX” appears next to the indoor  
and remote temperatures.  
4. The recorded maximum temperature  
is displayed. The time of the  
maximum outdoor temperature will  
also flash.  
5. Press and release the “MIN/MAX”  
button to exit min/max mode.  
6. To view optional additional sensors,  
press and release the “SET” button  
while viewing the minimum or  
maximum.  
11  
 
Resetting Min and Max Temperatures  
To reset both the minimum and maximum  
temperatures—press and hold the  
“RESET/+” button for 4 seconds.  
12  
 
Adding Additional Remote  
Temperature Sensors (optional)  
The WS-7034U is able to receive signals  
from 3 different remote temperature  
sensors. Following are some brief  
instructions for the basic set-up of  
remote temperature sensor units with the  
WS-7034U. These extra remote  
temperature sensors can be purchased  
through the same dealer as this unit, or  
by contacting La Crosse Technology  
directly. A TX6U will monitor  
temperature only, a TX3U will monitor  
temperature and display the temperature  
on its LCD, and the TX3UP will monitor  
the temperature of water or soil via a  
probe.  
When setting up multiple remote  
temperature sensors, it is important to  
remove the batteries from all existing  
units in operation, then to insert batteries  
first into all the remote temperature  
sensors. Second install batteries into the  
13  
 
indoor temperature station and do not  
press any buttons for ten minutes.  
Transmission problems will arise if this  
is not done correctly.  
To view the temperature of a different  
remote temperature sensor unit, press  
and release the “SET/CH” button. A  
shift from one number to the next should  
be observed in the OUTDOOR LCD.  
14  
 
MOUNTING  
Note: To achieve a true temperature  
reading, avoid mounting in direct sunlight.  
We recommend that you mount the remote  
temperature sensor on a North-facing wall.  
The sending range is 80ft; obstacles such as  
walls, concrete, and large metal objects will  
reduce the range. Place both units in their  
desired location before permanently  
mounting.  
Remote Temperature Sensor  
1. Remove the mounting bracket from the  
remote temperature sensor.  
2. Mount the bracket in the desired  
location with either screws or adhesive  
tape.  
3. Reattach the remote temperature sensor  
into mounting bracket.  
15  
 
Indoor Temperature Station  
The indoor temperature station comes with  
the table stand already mounted. If you wish  
to use the table-stand all that is required is to  
place the indoor temperature station in an  
appropriate location.  
1. To wall mount the indoor temperature  
station first remove the table stand.  
2. Next insert an appropriate screw in  
your desired location.  
3. Using the integrated hanging hole on  
the back of the unit, slip indoor  
temperature station over the screw and  
pull down to secure.  
16  
 
TROUBLESHOOTING  
NOTE: For problems not solved, please  
contact La Crosse Technology via e-mail or  
phone, or visit our website,  
Problem: The LCD is faint  
Solution: Replace batteries  
Problem: No outdoor temperature is  
displayed.  
Solution:  
1. Remove all batteries, reinsert into  
remote temperature sensor first, then  
into the indoor temperature station.  
2. Place remote temperature sensor closer  
to the indoor temperature station.  
3. Be sure all batteries are fresh.  
4. Place remote temperature sensor and  
indoor temperature station in position  
so the straight-line signal is not passing  
through more than two or three walls.  
Problem: Temperatures do not match if  
units are placed next to each other.  
17  
 
Solution:  
Each temperature sensor is manufactured to  
be accurate to within 1 degree plus or minus  
and under normal conditions, so two sensors  
could be as much as 2 degrees different.  
However, the difference can be exaggerated  
further because the sensors are designed for  
different working environments. The indoor  
sensor is less responsive to ambient air  
currents because of the shielding effect of  
the display's case. In addition, the case can  
act as a heat sink to absorb and store heat  
from external sources (i.e. handling of the  
case or radiant heat). Also, the much greater  
range of the outdoor temperature sensor  
requires a different calibration curve than the  
indoor range. Error is usually greater at the  
extreme ends of a range, making it harder to  
compare different ranges with different  
curves. Under non-laboratory conditions, it  
is difficult to compensate for the above  
factors and obtain an accurate comparison.  
MAINTENANCE AND CARE  
INSTRUCTIONS  
18  
 
Extreme temperatures, vibration, and  
shock should be avoided to prevent  
damage to the units.  
Clean displays and units with a soft,  
damp cloth. Do not use solvents or  
scouring agents; they may mark the  
displays and casings.  
Do not submerge in water.  
Do not subject the units to unnecessary  
heat or cold by placing them in the  
oven or freezer.  
Opening the casings invalidates the  
warranty. Do not try to repair the unit.  
Contact La Crosse Technology repairs.  
19  
 
SPECIFICATIONS  
Transmitting  
433MHz  
Frequency  
Measuring Temperatures  
Indoor  
Temperature  
Station  
32°F to 156.2°F with 0.2  
°F resolution.  
(0°C to 69.0°C with  
0.1°C resolution).  
Remote  
Temperature  
Sensor  
-21.8 °F to 156.2°F with  
0.2°F resolution.  
(-29.9°C to 69.0°C with  
0.1°C resolution).  
Temp accuracy  
Transmitting  
range  
+/- 1°F (+/- .5°C).  
Maximum 80 feet (25m)  
open space.  
Temperature check  
Indoor  
Outdoor  
Every 10 seconds.  
Three times in 10  
minutes.  
Batteries—(Alkaline recommended)  
Remote  
2 x AA, 1.5V  
Temperature  
Sensor  
20  
 
Indoor  
2 x AAA, 1.5V  
Temperature  
Station  
Dimensions: (L x W x H)  
Indoor  
2.36 x .88 x 5.90 in.  
Temperature  
Station  
Remote  
Temperature  
Sensor  
(excluding table stand)  
(60 x 22.5 x 150 mm).  
2.32 x 0.86 x 2.55 in.  
(59 x 22 x 65 mm).  
Battery life  
Approximately 1 year.  
WARRANTY INFORMATION  
La Crosse Technology, Ltd provides a 1-year limited  
warranty on this product against manufacturing  
defects in materials and workmanship.  
This limited warranty begins on the original date of  
purchase, is valid only on products purchased and  
used in North America and only to the original  
purchaser of this product. To receive warranty  
service, the purchaser must contact La Crosse  
Technology, Ltd for problem determination and  
service procedures. Warranty service can only be  
performed by a La Crosse Technology, Ltd  
21  
 
authorized service center. The original dated bill of  
sale must be presented upon request as proof of  
purchase to La Crosse Technology, Ltd or La  
Crosse Technology, Ltd’s authorized service center.  
La Crosse Technology, Ltd will repair or replace this  
product, at our option and at no charge as stipulated  
herein, with new or reconditioned parts or products if  
found to be defective during the limited warranty  
period specified above. All replaced parts and  
products become the property of La Crosse  
Technology, Ltd and must be returned to La Crosse  
Technology, Ltd. Replacement parts and products  
assume the remaining original warranty, or ninety  
(90) days, whichever is longer. La Crosse  
Technology, Ltd will pay all expenses for labor and  
materials for all repairs covered by this warranty. If  
necessary repairs are not covered by this warranty,  
or if a product is examined which is not in need or  
repair, you will be charged for the repairs or  
examination. The owner must pay any shipping  
charges incurred in getting your La Crosse  
Technology, Ltd product to a La Crosse Technology,  
Ltd authorized service center. La Crosse  
Technology, Ltd will pay ground return shipping  
charges to the owner of the product to a USA  
address only.  
Your La Crosse Technology, Ltd warranty covers all  
defects in material and workmanship with the  
following specified exceptions: (1) damage caused  
by accident, unreasonable use or neglect (including  
22  
 
the lack of reasonable and necessary maintenance);  
(2) damage occurring during shipment (claims must  
be presented to the carrier); (3) damage to, or  
deterioration of, any accessory or decorative  
surface; (4) damage resulting from failure to follow  
instructions contained in your owner’s manual; (5)  
damage resulting from the performance of repairs or  
alterations by someone other than an authorized La  
Crosse Technology, Ltd authorized service center;  
(6) units used for other than home use (7)  
applications and uses that this product was not  
intended or (8) the products inability to receive a  
signal due to any source of interference.. This  
warranty covers only actual defects within the  
product itself, and does not cover the cost of  
installation or removal from a fixed installation,  
normal set-up or adjustments, claims based on  
misrepresentation by the seller or performance  
variations resulting from installation-related  
circumstances.  
LA CROSSE TECHNOLOGY, LTD WILL NOT  
ASSUME LIABILITY FOR INCIDENTAL,  
CONSEQUENTIAL, PUNITIVE, OR OTHER  
SIMILAR DAMAGES ASSOCIATED WITH THE  
OPERATION OR MALFUNCTION OF THIS  
PRODUCT. THIS PRODUCT IS NOT TO BE USED  
FOR MEDICAL PURPOSES OR FOR PUBLIC  
INFORMATION. THIS PRODUCT IS NOT A TOY.  
KEEP OUT OF CHILDREN’S REACH.  
23  
 
This warranty gives you specific legal rights. You  
may also have other rights specific to your State.  
Some States do no allow the exclusion of  
consequential or incidental damages therefore the  
above exclusion of limitation may not apply to you.  
For warranty work, technical support, or information  
contact:  
La Crosse Technology  
2809 Losey Blvd. S.  
La Crosse, WI 54601  
Phone: 608.782.1610  
Fax: 608.796.1020  
e-mail:  
(warranty work)  
(information on other products)  
web:  
FCC DISCLAIMER  
This device complies with part 15 of the FCC  
rules. Operation is subject to the following two  
conditions: (1) this device may not cause harmful  
24  
 
interference, and (2) this device must accept any  
interference received, including interference that  
may cause undesired operation.  
Freq. 433.92 MHz  
La Crosse Technology  
Made in China  
WS-7034U  
FCC ID: OMO-01RX (Receiver), OMO-01TX  
(sensor)  
THIS DEVICE COMPLIES WITH PART 15  
OF THE FCC RULES. OPERATION IS  
SUBJECT TO THE FOLLOWING TWO  
CONDITIONS:  
1. THIS DEVICE MAY NOT CAUSE  
HARMFUL INTERFERENCE, AND  
2. THIS DEVICE MUST ACCEPT  
INTERFERENCE RECEIVED, INCLUDING  
INTERFERENCE THAT MAY CAUSE  
UNDESIRED OPERATION.  
25  
 

LG Electronics Air Compressor R 134a User Manual
Life Fitness Exercise Bike lc5500 User Manual
Lincoln Electric Welder 10A User Manual
LOREX Technology Security Camera SG14S1022P User Manual
LST Smoke Alarm M400DKMB AS User Manual
Lux Products Washer CAG1500 User Manual
Marantz Speaker SW7001 User Manual
Maytag Dishwasher 760S User Manual
Memorex CRT Television MT1192 User Manual
Meridian Audio Home Theater System FPP 61HD20 User Manual