INTRODUCTION  
This equipment dispenses granita-type and cold liquid drinks on demand from separate hoppers. Operating controls  
are accessible only through password protection.  
CONTENTS  
Introduction & Warranty....................................................................................................... 3  
Operating Controls ............................................................................................................... 8  
Programming....................................................................................................................... 6  
Switches ........................................................................................................................ 6  
Programming the Dispenser.......................................................................................... 7  
Function Index ............................................................................................................... 7  
Cleaning Guide............................................................................................................... 9  
Set Consistency ........................................................................................................... 10  
Test Augers.................................................................................................................. 11  
Set Time & Date........................................................................................................... 11  
Password..................................................................................................................... 12  
Set Language............................................................................................................... 12  
Set Night/Day Time...................................................................................................... 13  
Preventive Maintenance............................................................................................... 14  
Days to Clean............................................................................................................... 15  
Consistency Adjust Lock.............................................................................................. 16  
Switches Enabled......................................................................................................... 17  
Refill Threshold............................................................................................................ 18  
Ad Message Enabled.................................................................................................... 19  
Enter Asset Number..................................................................................................... 20  
Set Password............................................................................................................... 20  
Restore Defaults .......................................................................................................... 21  
Install Date................................................................................................................... 21  
Temperature & Torque ................................................................................................. 22  
41047 040108  
3
OPERATING CONTROLS  
ULTRA-1  
There are three of these switches that will be used for the operation of the dispenser.  
1
2
3
P3932  
1.  
switch (upper left corner of the control pad)  
This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON  
the Date and Time toggle back and forth continously except during programming.  
2.  
(upper right corner)  
This is used to turn the auger motor to AUGER ON, AUGER OFF or AUGER REFILL ON. (Refill only ap-  
plicable when installed)  
3.  
(lower right corner)  
This is used to turn the ice control to OFF, ICE or CHILL.  
41047 040108  
4
OPERATING CONTROLS  
ULTRA-2  
There are five of these switches that will be used for the operation of the dispenser.  
1
P3677  
2
3
4
5
1.  
switch (upper left corner of the control pad)  
This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. When ON  
the Date and Time toggle back and forth continously except during programming.  
2.  
(bottom left corner)  
This is used to turn the left side auger motor to AUGER ON, AUGER OFF or AUGER REFILL ON. (Refill  
only applicable when installed)  
3.  
(bottom left corner)  
This is used to turn the left side ice control to OFF, ICE or CHILL.  
4.  
(bottom right corner)  
This is used to turn the right side auger motor AUGER ON, AUGER OFF or AUGER REFILL ON. (Refill only  
applicable when installed)  
5.  
(bottom right corner)  
This is used to turn the right side ice control to OFF, ICE or CHILL.  
41047 040108  
5
PROGRAMMING  
Using the menu-driven display on the front of the dispenser, the operator has the ability to alter or modify  
various parameters such as beverage consistency and set day/night “ON/OFF” times. The operator is also  
prompted to check a variety of periodic service functions or even a step-by-step cleaning routine. There is also  
the opportunity to return all changes back to factory default settings.  
Access to most controls can be password protected to allow only qualified personnel to make changes.  
1
1
4
2
P3931  
P3677  
2
3
4
3
ULTRA-1  
ULTRA-2  
PROGRAMMING SWITCHES  
To access the programming mode, and to scroll through the different function screens, hidden programming  
switches are used. There are three of these switches that will be used for the setup of the dispenser.  
1. I/O switch (upper left corner of the control pad)  
This switch is the ON/OFF toggle switch which powers up the dispenser and the LCD display. This switch is  
also used as back up switch in menu mode.  
2. “GOURMET” (center under display)  
Press and hold this switch 5 seconds to access the Menu Function Index. This switch is also used as “NEXT”  
to scroll through the functions.  
3. “ULTRA” (left under display)  
When prompted by a selection from the menu to answer yes or no, the “ULTRA” switch is used to answer  
“NO” or (-) minus.  
4. “ICE” (right under display)  
When prompted by a selection from the menu to answer yes or no, the “ICE” switch is used to answer “YES”  
or (+) plus.  
41047 040108  
6
PROGRAMMING THE DISPENSER  
During normal operations, the Date, the Time, and the Serial Number toggle back and forth continuously. The  
following function screens are in the order they appear from the menu display. Each screen will have instructions  
and procedures to program the various functions of the dispenser.  
HOME SCREEN  
Displays the TIME, DATE, SERIAL NUMBER and ASSET NUMBER which toggle back and forth continuously.  
JAN. 25, 2005  
off off  
10:45:30 AM  
off  
off  
off  
off  
ULTR027930  
AN000001  
off  
off  
MENU FUNCTION INDEX  
Press and hold for five seconds the GOURMET hidden switch to enter into the Menu Function Index. The screens  
on the following page are in order that they appear from the menu display. Pressing NO (“ULTRA”) or NEXT  
(GOURMET”) will advance to the next function. Press ON/OFF (“I/O”) will back up to the previous screen. A one  
minute time out will return to the Home Screen.  
JAN. 25, 2005  
off  
off  
P3678  
41047 040108  
7
MENU FUNCTION INDEX (Continued)  
TEST AUGERS ?  
NO YES  
SET THICKNESS ?  
CLEANING GUIDE ?  
NO  
YES  
NO  
YES  
SET LANGUAGE ?  
NO YES  
PASSWORD 0  
SET DATE TIME ?  
(-)  
NEXT  
(+)  
NO  
YES  
PM COMPLETE ?  
NO YES  
DEFROST MINUTES  
(-) OFF (+)  
SET NIGHT TIME  
(-) OFF (+)  
YES THICK ADJUST  
(-) NEXT (+)  
DAY TO CLEAN OFF  
(-) NEXT (+)  
6 MONTH PM  
(-)  
OFF  
(+)  
250 R REFILL 155  
(-) THRESHOLD (+)  
250 L REFILL 155  
(-) THRESHOLD (+)  
SWITCHES  
ON  
(-)  
(+)  
ENTER ASSET #  
AN000000  
AD MESSAGE  
(-) DISABLED (+)  
TEST REFILL ?  
NO YES  
SET PASS WR 0  
(-) NEXT (+)  
RESTORE DEFAULT?  
These screens apply to Liquid  
Autofill models only!  
NO  
YES  
41047 040108  
8
Cleaning Guide  
This function leads the operator through a nine step cleaning process when answered YES (“ICE”). Depress  
GOURMET to display the next cleaning instruction.  
When entering this mode, the refrigeration system will automatically turn OFF. After step when hoppers are  
drained, the augers will turn OFF. Three messages will display after advancing past the last cleaning instruc-  
tion:  
FINISH/NEXT, PLEASE WAIT, ULTRA VERSION #__.__.  
CLEANING GUIDE ?  
NO  
Y E S  
P3678  
REMOVE HOPPERS  
AUGERS & SEALS  
WASH & SANITIZE  
DRAIN HOPPERS  
NEXT  
ALL PARTS  
STEP 3  
STEP 2  
STEP 1  
WASH DRIP  
TRAY  
RE-INSTALL  
HOPPER SEALS  
WASH FREEZING  
BARRELS  
STEP 6  
STEP 5  
STEP 4  
RE-INSTALL  
HOPPERS & LIDS  
REFILL WITH  
PRODUCT  
RE-INSTALL  
AUGERS  
STEP 9  
STEP 8  
STEP 7  
PLEASE WAIT  
ULTRA II  
VERSION # __.__  
FINISH  
NEXT  
41047 040108  
9
Set Consistency  
This function allows the operator to adjust the ice consistency, or torque of each auger when answered YES  
(“ICE”). Two screens will appear for left and right. The operator can scroll through a range of a minimum of 1  
(ULTRA) to a maximum of 16 (ICE). Factory default is 10.  
NOTE: ULTRA-1 models will only have one adjustment screen.  
SET THICKNESS ?  
NO  
YES  
P3678  
MIN RIGHT 5 MAX  
MIN LEFT 9 MAX  
41047 040108  
10  
Test Augers  
This function tests the operation of forward and reverse of each auger motor. Left auger appears first. Press  
the ICE hidden switch to toggle between OFF, FORWARD and REVERSE. Press GOURMET hidden switch to repeat  
the operation for the right auger motor. A one minute time out will return to the Home Screen.  
LEFT AUGER TEST  
NEXT FORWARD  
TEST AUGERS ?  
NO YES  
LEFT AUGER TEST  
NEXT OFF  
LEFT AUGER TEST  
NEXT REVERSE  
Select NEXT to repeat process for Right Auger Test.  
NOTE: ULTRA-1 models will only have one test screen.  
Set Time and Date  
Selecting YES (ICE) allows the operator to set the DATE (YY MM DD) and TIME (HR MIN SEC) for display  
on the Home Screen.  
SET DATE TIME ?  
NO  
YES  
MONTH DAY 25  
MONTH  
(-) NEXT  
1
(+)  
YEAR 2005  
(-) NEXT  
(+)  
(-) NEXT  
(+)  
MINUTE  
(-) NEXT  
45  
(+)  
SECOND  
(-) NEXT  
30  
(+)  
HOUR 10 AM  
(-) NEXT  
(+)  
41047 040108  
11  
Password  
From this screen, the operator must know the password before moving on to the remaining functions. The  
range is from 0 - 9999 with the factory default being 0.  
PASSWORD 0  
(-) NEXT (+)  
P3678  
Set Language ? (Late Model Dispensers)  
The setting of the Set Language mode allows the operator to scroll thru a list of languages stored in the  
software and select one for the display messages.  
SET LANGUAGE ?  
NO  
YES  
ESPANOL  
(-) SELECCIONE (+)  
ENGLISH  
SELECT  
(-)  
(+)  
CHANGE LANGUAGE?  
CHANGE LANGUAGE?  
ARE YOU SURE?  
NO  
YES  
41047 040108  
12  
Set Night Time/Set Day Time  
The setting of the Day/Night mode allows the dispenser to “power down” during off hours. The bottom corners  
displaying “ICE” will change to “CHILL” during the night mode. During the night mode, the product will be kept  
chilled to below 35°F. ICE” reading will return after night mode elapses. With “OFF” representing 12:00 AM, the  
operator can scroll to the times desired for the night time mode to begin and end.  
SET NIGHT TIME  
SET DAY TIME  
(-) OFF (+)  
(-)  
OFF  
(+)  
NIGHT TIME MODE  
CHILL  
CHILL  
This feature allows the machine to defrost the product during day time operation. The defrost minutes set-  
ting will select the defrost time period. The freeze minutes setting will select the freeze time between defrost  
periods. These modes when activated will function anytime the machine is in day mode operation. The machine  
will automatically stay in the freeze mode for 2 hours after waking up from the night time mode.  
DEFROST MINUTES  
(-)  
OFF (+)  
FREEZE MINUTES  
(-)  
60  
(+)  
41047 040108  
13  
Preventive Maintenance Complete?  
This function is used to reset a reminder message Preventive Maintenance Due every six months. The machine  
will not shut down if service is not performed. When the service is performed and the message is answered YES  
(ICE), the time and date is recorded for another six months to elapse. This feature can be DISABLED by pressing  
(-) ULTRA hidden switch.  
PM COMPLETE ?  
NO  
YES  
6 MONTH PM  
(-)  
ON  
(+)  
41047 040108  
14  
Day To Clean Off  
This function allows the operator to program a cleaning schedule from 1 to 14 days. The default screen is  
0 or OFF. Selecting - or ULTRA will prompt the screen Days To Clean. Once a number of days is selected the  
screen will prompt two functions, CLEAN MESSAGE ONLY or CLEAN LOCKOUT. On the day selected, the display  
will toggle between DATE & TIME and CLEAN DUE TODAY. The dispenser will lock into night mode at midnight if  
“Clean Lockout” is activated. To reset the Clean Due Today message or lockout, two functions must be performed.  
Either power off the dispenser using the I/O (ON/OFF) switch and allow the barrels or cooling drums to warm  
over 50°F, or scroll to the Cleaning Guide and perform the cleaning service. The barrels will warm to over 50°F  
when cleaned with warm water and the message will disappear.  
NOTE: The “CLEAN DUE TODAY” and “CLEAN DUE NOW” messages may be customized on late model ma-  
chines. All users should be trained to know the machine needs cleaning when the custom message appears on  
the display.  
DAYS TO CLEAN 14  
(-) NEXT (+)  
DAY TO CLEAN OFF  
(-) NEXT (+)  
CLEAN LOCKOUT  
(-) NEXT (+)  
CLN MESSAGE ONLY  
(-) NEXT (+)  
Late Model Dispensers  
MODIFY MESSAGE ?  
NO  
YES  
SCROL THRU ALPHA  
NEXT-NEXT LETTER  
(MESSAGE)  
SCROL DONE NEXT  
SAVE ?  
EDIT  
CUSTOM MESSAGE  
SETUP COMPLETE  
NO  
YES  
41047 040108  
15  
Consistency Adjust Lock  
This is an option of locking the Set Consistency function by selecting + (YES) or - (NO).  
NO THICK ADJUST  
(-) NEXT (+)  
YES THICK ADJUST  
(-) NEXT (+)  
41047 040108  
16  
Switches Enabled  
This function allows the operator to lockout the touch pad. Selecting + (ON) provides no time delay on switches  
except for the center (GOURMET) hidden switch. Selecting - (LOCKOUT) provides a five second hold to wake up  
the touch pad and a two minute time frame from last button pressed to make adjustments before returning to  
sleep mode (five second hold).  
SWITCHES  
ON  
SWITCHES  
(-) LOCKOUT (+)  
(-)  
(+)  
41047 040108  
17  
Refill Threshold (Late Model Dispensers with Refill Kit Installed only)  
This function allows the operator to adjust the Refill Threshold depending on the type of product being dis-  
pensed.  
250 L REFILL 155  
(-) THRESHOLD (+)  
250 R REFILL 155  
(-) THRESHOLD (+)  
TEST REFILL ?  
NO  
YES  
ACTIVATE VALVE  
LEFT DONE RIGHT  
ULTRA-1 Models only:  
This function will activate the Liquid Autofill function only in machines equipped with this option.  
ENABLE REFILL ?  
(-)  
OFF  
(+)  
41047 040108  
18  
Ad Messages Enabled (Late Model Dispensers)  
This function allows the operator to create an AD Message that will toggle with the Home Screen mes-  
sages.  
AD MESSAGE  
AD MESSAGE  
(-) DISABLED (+)  
(-) ENABLED (+)  
MODIFY MESSAGE ?  
NO  
YES  
SCROL THRU ALPHA  
NEXT-NEXT LETTER  
(MESSAGE)  
SCROL DONE NEXT  
SAVE ?  
AD MESSAGE  
NO  
EDIT  
YES  
SETUP COMPLETE  
41047 040108  
19  
Enter Asset Number  
This is the function to set the asset number using a range of 0 to 999999 (the factory default is 0). It is used  
to track the usage or service of an individual machine within a group.  
ENTER ASSET #  
AN000000  
Set Password  
This is the function to set the password using a range of 0 to 9999 (the factory default is 0). When the pass-  
word is set, the operator can only access the first four functions: Cleaning Guide, Set Consistency, Test Augers  
and Set Date & Time.  
SET PASS WR 9999  
(-) NEXT (+)  
SET PASS WR 0  
(-) NEXT (+)  
41047 040108  
20  
Restore Default?  
Answering YES (ICE) to this function returns the unit back to preset factory constants.  
1. Set Consistency ? 8  
2. Set Night Time - DISABLED  
3. Set Day Time - DISABLED  
4. 6 Month PM - ON  
5. Days....Off - OFF  
6. Torque Adjust Lock - YES  
7. Switches On - ON  
RESTORE DEFAULT ?  
NO  
YES  
8. Set Password - 0  
9. R Refill Threshold - 155  
10. L Refill Threshold - 155  
11. Cleaning Message - RESET  
12. AD Message - RESET  
ARE YOU SURE ?  
RESTORE DEFAULTS  
423  
NO  
YES  
Install Date  
The following three screens will scroll after advancing past the function “Restore Defaults”. The Install Date  
and Time is recorded when the dispenser is powered on for the first 100 hours. The Install Date and Time cannot  
be reset and is stored in permanent memory.  
INSTALL DATE  
ULTRA  
VERSION # __.__  
JAN. 20, 2005  
3:55:25 PM  
41047 040108  
21  
TEMP & TORQUE  
Press and hold for five seconds the ULTRA and ICE hidden switches to display the TEMP & TORQUE. The tempera-  
ture of each cooling drum and the hot gas temperature will toggle back and forth. The auger torque is displayed  
continuously. Press and release the ULTRA and ICE hidden switches to return to HOME SCREEN.  
The TEMP & TORQUE mode is typically used for service.  
DISPLAY  
TEMP & TORQUE  
0
0
0
0
67  
67°h  
36  
36°  
NOTE: ULTRA-1 models will display Barrel Temperature and Torque readings on the left side of the display.  
41047 040108  
22  

Alpine CDA 9811R User Manual
Best Buy RF QX4 J User Manual
Bushnell YP SPORT 450 20 1920 User Manual
Canon Speedlite 90EX Flash Speedlite 90EX User Manual
Crown Boiler KSZ090 User Manual
Eclipse Fujitsu Ten Car Stereo System CD3424 User Manual
Fusion Electronics Car Amplifier CA AM10900 User Manual
Gitzo Classic Sport G1226 User Manual
Jensen CD3720XM User Manual
JVC 1000MKV_UN_VP User Manual