TRITON T1 BOARD
QUICK INSTALLATION GUIDE
MVIP BUS
MVIP Connector
System
Termination Switch
Configuration Switch
TRITON T1 BOARD
The Triton T1 Board uses the following signaling and framing features:
Signaling: loop start, ground start, E&M immediate start, E&M wink start*
Line Encoding: AMI, B8ZS*
*recommended
MINIMUM SYSTEM REQUIREMENTS:
• IBM/PC AT compatible system with adequate number of full-size ISA and PCI slots
• 233 Mhz Pentium processor (or better)
• 2 - 4 GB Hard Disk Drive Space (depending on voicemail requirements)
• Windows NT Server 4.0 with Service Pack 4 (or higher) installed
• 128 MB RAM
• AltiGen’s Quantum Telephony Board (one or more, Rev. D or higher)
• AltiGen’s Triton T1 Board (one or more)
• AltiWare OE R3.0 (or higher)
• 300W/10A CPU Power (minimum required to power AltiGen boards only)
• CSU (Channel Service Unit)
# of AltiGen Boards
# of Slots** CPU
HDD
1 Triton T1, 1-3 Quantum
1 Triton T1, 1-6 Quantum
1-4 Triton T1, 1-10 Quantum
2 PCI, 3 ISA
2 PCI, 6 ISA
233 Mhz
300 Mhz
2GB
2GB
4GB
5 PCI, 10 ISA 350 Mhz
# of AltiGen Boards
Power Supply**
Typical Power Supply
1 Triton T1, 1-3 Quantum
1 Triton T1, 1-6 Quantum
1-4 Triton T1, 1-10 Quantum
+12V: 4.2 Amps +5V: 6Amps
300W/30A@5V/12A@12V
400W/40A@5V/16A@12V
400W/40A@5V/16A@12V
+12V: 8.4 Amps +5V: 10.8Amps
+12V: 14 Amps +5V: 21Amps
** The above system requirements are for AltiGen components only, and do not take into account requirements for other
system components such as motherboard, disk drives, etc.
LED Indicators
GREEN LED
RED LED
Status
OFF
ON
OFF
OFF
No power
Normal operation
OFF
ON
No signal
ON
OFF
Alternating
Flashing
Flashing
Alternating
Faulty signal with frame synchronization***
Faulty signal without frame synchronization
Frame slips in normal operation
*** Faulty signals include the following: yellow alarm, bipolar violation or frame error
STEP 3: CONNECT THE MVIP CABLE AND TERMINATE THE MVIP BUS
IMPORTANT! Make sure the MVIP bus is terminated (set to close) at the
Quantum Board with ID of 0. All other boards are not terminated (MVIP Bus
Termination Switch set to OPEN). DO NOT TWIST THE MVIP
CABLE. It should lay flat when connected to boards, as shown below.
The MVIP Bus is only terminated on one board per system.
CPU Board
Triton
Quantum
MVIP Bus Termination
Switch CLOSE
0
1
CPU
3
2
1
0
STEP 4: CONNECT CSU (CHANNEL SERVICE UNIT) TO TRITON T1 BOARD
Using Adtran’s CSU (model T1 CSU ACE) as an example, connect your CSU to
the Triton T1 board using on RJ-48C or RJ-48X cable. Then, connect your CSU
to your network termination box using an RJ-48C or RJ-48X cable.
Central
Office
CPE
CSU
T1 Line
Network
Termination
Box
Net
Power
RJ48c or
RJ-48x cable
RJ48c or
RJ-48x cable
For Adtran CSU
For T1 Socket (RJ-48)
Receive Ring = Pin 1
Receive Tip = Pin 2
Transmit Ring = Pin 4
Receive Tip = Pin 5
NOTE: The default settings for the equipment Line Build Out (LBO) and the network
LBO are for distances shorter than 133 ft.
CAUTION: Switch ON the Manual Loopback (LB) when the equipment connection
(from the Triton Board) is not ready. This will give the CO good signal and prevent the
CO from switching off service. Switch OFF the Manual LB in normal operation.
STEP 6: TURN SYSTEM ON AND INSTALL ALTIWARE OE
OR START ALTIWARE OE TO CONFIGURE NEW T1 TRUNKS
Please see the following sections in the AltiWare OE manuals for details
on how to configure T1 trunks:
• System Administration Manual
Chapter 3, Board Configuration
Chapter 4, Trunk Configuration
TECHNICAL SUPPORT
• End users, please contact your Authorized AltiGen Dealer.
• Authorized AltiGen Dealers,
Call AltiGen Technical Support at 1-888-ALTIGEN (258-4436)
Send E-mail to: [email protected]
• Please provide the following information so that the support
representative can provide fast service and solution to your problem.
Serial #: ________________ AltiWare Release #: _____________
Server HW: CPU _______, Memory _______, Hard Drive _______
# of AltiGen boards installed: Quantum________ Triton ________
Description of the problem:
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
AltiGen Communications, Inc.
©AltiGen Communications, Inc. Rights Reserved. Printed in USA. 9/99 4005-0006-A2
|