XRN Interconnect Module (3C17716)
XRN Interconnect Module Kit (3C17715)
User Guide
DUA1771-5AAA02
Consol
(max) 19200,8
Unit 1
Unit 2
S/N:
XXXX/7XXXXXXXXXX
Activity
Status
3C17716
XRN Inter
connect Module
odule
INTRODUCTION
panel of the Module. For explanations on how the LEDs
Introducing the XRN Interconnect Module Kit
With an XRN Interconnect Module Kit (3C17715) you can
interconnect two Switch units.
The Interconnect Cable
The Interconnect Cable is used to interconnect two Switch
This kit contains:
units, both fitted with Interconnect Modules.
Two XRN Interconnect Modules (3C17716)
The standard Interconnect Cable is 1 m (3.28 ft) long and
color-coded with a yellow marker at one end and a blue
marker at the other end.
One standard XRN Interconnect Cable (3C17721)
The Switches that support this module are:
®
SuperStack 3 Switch 4900
SuperStack 3 Switch 4900 SX
SuperStack 3 Switch 4924
SuperStack 3 Switch 4950
The end of the Interconnect Cable that you connect to the
Switch determines the identity of the Switch. The Switch
that has the blue end of the cable connected to it will be
Unit 1. The Switch that has the yellow end of the cable
connected to it will be Unit 2.
®
3Com Switch 4060
The terms Unit 1 and Unit 2 are used simply to identify
the Switch units for management purposes only.
3Com Switch 4050
Figure 1 The Interconnect Cable
The Interconnect Module requires management software
version 3.0 or later to be installed on the Switch. For
instructions on upgrading the management software, refer
to the documentation supplied with your Switch.
You can gather information about the status of the
Module and its packet activity using the Expansion Module
LEDs on the front of the Switch and the LEDs on the front
Blue Marker / Unit 1
Yellow Marker / Unit 2
1
INTERCONNECTING TWO SWITCHES
CAUTION: 3Com recommends that you do not connect or
Interconnecting Two Switches
disconnect the Interconnect Cable when the Switches are
in use. If you do, the flow of data will be affected and
your network configuration settings may change.
To interconnect two Switches, you will need the XRN
Interconnect Module Kit (part number 3C17715). This kit
contains:
!
Two XRN Interconnect Modules (3C17716)
LED Function Tables
One standard XRN Interconnect Cable (3C17721)
You can gather information about the status of the
Module and its packet activity using the Expansion Module
You can interconnect two Switch units that are located in
separate racks with a 5 m (16.40 ft) long Interconnect
cable (3C17722). Contact your network supplier for
further information.
!
Table 1 Switch LED Function Table
CAUTION: It is important that you only plug an XRN
Interconnect Cable (3C17721 or 3C17722) into the
connector on the XRN Interconnect Module (3C17716).
Expansion Module Activity LED
Status
Color
Meaning
On
Yellow
Packets are being transmitted or received on the
Module.
Connecting any other 9-way plug into the connector on
the XRN Interconnect Module could result in damage to
your hardware.
Off
No color There are no packets being transmitted or received on
the Module.
Expansion Module Status LED
The end of the Interconnect Cable that you connect to the
Switch determines the identity of the Switch. The Switch
that has the blue end of the cable connected to it will be
Unit 1. The Switch that has the yellow end of the cable
connected to it will be Unit 2.
Status
Off
Color
Meaning
No color The Module is not installed.
Flashing
Yellow
The Module is installed but is not recognised (faulty or
unsupported).
The terms Unit 1 and Unit 2 are used simply to identify
the Switch units for management purposes only.
On
On
Yellow
Green
The Module is installed but no link is present.
The Module is installed and a link is present.
Figure 3 Interconnecting Two Switches
Unit 1—4 LED
Status
Color
Green
Meaning
Unit 1: Blue End of Cable
Switch 4900
Se
M
3C
ria
17
70
l
N
o
X
X
0
A
C
X/
X
X
XX
A
dd
r:
XX
XX
XX
X
XX
XX
XX
X
XX
XX
SUP
PL
Y
DA
TA
V-
90
-
24
0
H
/6
z
50
A
On
Determines the identity of the Switch when intercon-
nected to another Switch to create an XRN Distrib-
uted Fabric and that a link is present.
0
4.
I
5
RE
M
IN
FE
AN
PUT
V
R
UA
T
O
I
NS
TR
UC
TIO
L
F
OR
CO
RR
EC
N
A
Ma
x
27
T
12
Console
o
Unit
1
1
2
2
(max) 19
n
200,,
n
so
it
Unit
a
le
x)
1
9
2
0
0
,8
,1
n
Activity
tivity
Status
,N
S/N:
it
c
:
XXXX/7XXXXXXXXX
X
X
X
/7
X
X
X
tatus
X
X
X
X
X
X
Unit 2: Yellow End of Cable
Switch 4900
Se
M
3C
ria
17
X
X
Off
No color A fault has occurred.
l
N
70
XX
XX
o
0
XX
A
C
X/
X
A
dd
r:
3C17716
6
X
XX
C
X
1
X
XX
XX
7
X
X
7
X
X
1
XX
XRN Inter
rconnect Module
R
N
In
te
o
n
n
e
ct
M
o
d
u
le
SUP
PL
Y
DA
TA
V-
90
-
240
H
/6
z
50
A
4.
0
5
I
RE
M
INPUT
FE
AN
R
UA
T
O
L
I
NS
TR
UC
TIO
V
A
Ma
x
12
F
OR
C
N
OR
RE
27
CT
Table 2 Module LED Function Table
Con
o
Unit
1
1
2
2
(max) 19
n
200,8,1,N
n
so
it
Unit
a
le
x)
1
9
2
0
0
,8
,1
n
Activity
tiv
ity
,N
S/N:
it
c
N
:
XXXX/7XXXXXXXXX
X
X
X
/7
X
X
Status
tu
X
X
X
X
X
s
X
X
Activity LED
Status
On
3C17716
6
C
1
7
7
1
XRN Inter
rconnect Module
R
N
In
te
n
n
e
ct
M
o
d
u
le
Color
Meaning
Yellow
Packets are being transmitted or received on this port.
To interconnect two Switches:
Off
No color There are no packets being transmitted or received on
this port.
1 Install the Interconnect Modules into the Switch units, as
described on page 2.
Status LED
Status
On
2 Connect the Interconnect Cable to the Interconnect
Modules (see Figure 3).
Color
Meaning
3 Power-up the Switch units.
Green
A link is present and the port is enabled.
Off
No color There is no link present.
4 Check the LEDs on the front of the Switch and on the
front panel of the Module to ensure that the Module is
more information.
Unit 1—2 LED
Status
Color
Green
Meaning
On
Determines the identity of the Switch when
interconnected with another Switch. The LEDs indicate
‘Unit 1’ and ‘Unit 2’ respectively.
Always secure the Interconnect Cable to the Interconnect
Modules by tightening its securing screws.
MODULE PORT RESTRICTIONS
When using the Interconnect Module, note the following:
The Interconnect Module is not hot-insertable.
Only one Interconnect Module may be fitted into the
Switch.
The Interconnect Module only operates with the Switch
units listed on page 1.
The Interconnect Module is not hot-swappable.
3
.
PROBLEM SOLVING
If you suspect a problem, carry out these steps before
Check that the correct management software is being
used on the Switch.
contacting your supplier:
Check that the Interconnect Module is correctly
installed in the Switch.
If the Module Status LED on the front of the Switch is
flashing yellow, the Module is installed but not
supported by the Switch. The Switch will continue to
operate normally but you must upgrade the
management software on the Switch for it to recognize
and support the Module and enable the Module’s
ports. You can download the latest version of the
management software from the 3Com website at:
When you insert the Module into the Switch, push the
Module in until the Module’s back plate is in full
contact with the Switch’s chassis. Secure the Module to
the Switch by tightening the three captive screws fully
with a screwdriver. If an error is indicated during the
Power On Self Test, check that the module has been
correctly inserted.
Alternatively, if you received a CD-ROM with your
Module, you can upgrade your Switch with the
management software contained on the CD-ROM.
Check that the Interconnect cabling is correctly
connected and secured.
.
Check that the Switch, into which the Interconnect
Module is fitted, is powered-up.
TECHNICAL SUPPORT
If you require assistance, contact your Network Supplier first. If you require further assistance, the following options are available
for technical support:
Online Technical Services
3Com offers worldwide product support 24 hours a day, 7 days a week, through the following online systems:
Check the 3Com knowledgebase at http://knowledgebase.3com.com
Browse the 3Com web site on http://www.3com.com
Telephone Support
Please have your product model name, part number, hardware revision number and serial number along with all relevant details
of the problem to hand before calling your Network Supplier or 3Com on the numbers below.
Country
Telephone Number
Country
Telephone Number
Country
Telephone Number
Asia, Pacific Rim
Australia
Hong Kong
India
1 800 678 515
800 933 486
+61 2 9424 5179 or
000800 650 1111
001 803 61009
00531 616 439 or
03 5977 7991
Malaysia
New Zealand
Pakistan
1800 801 777
0800 446 398
Singapore
S. Korea
800 6161 463
00798 611 2230 or
02 3455 6455
00801 611 261
001 800 611 2000
+61 2 9937 5083
1235 61 266 2602 or
1800 1 888 9469
10800 61 00137 or
021 6350 1590 or
00800 0638 3266
Philippines
Taiwan
Thailand
Indonesia
Japan
P.R. of China
Europe, Middle East and Africa
From anywhere in these
regions, call:
+44 (0)1442 435529 phone
From the following countries, you may use the numbers shown:
Austria
01 7956 7124
070 700 770
7010 7289
01080 2783
0825 809 622
01805 404 747
Hungary
Ireland
Israel
06800 14466
1800 509359
1800 943 2632
199 161346
800 29880
0900 777 7737
815 33 047
Poland
00800 441 1357
707 200 123
0800 991196
9 021 60455
07711 14453
08488 50112
0870 241 3901
Belgium
Denmark
Finland
France
Portugal
South Africa
Spain
Sweden
Switzerland
U.K.
Italy
Luxembourg
Netherlands
Norway
Germany
Latin America
From the Caribbean, Central and South America, call:
Antigua
Argentina
Aruba
Bahamas
Barbados
Belize
Bermuda
Bonaire
Brazil
Cayman
Chile
1 800 988 2112
0 810 444 3COM
1 800 998 2112
1 800 998 2112
1 800 998 2112
52 5 201 0010
1 800 998 2112
1 800 998 2112
0800 13 3COM
1 800 998 2112
AT&T +800 998 2112
Colombia
Costa Rica
Curacao
AT&T +800 998 2112
AT&T +800 998 2112
1 800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
57 1 657 0888
AT&T +800 998 2112
1 800 998 2112
571 657 0888
Nicaragua
Panama
Paraguay
Peru
Puerto Rico
Salvador
Trinidad and Tobago
Uruguay
Venezuela
Virgin Islands
AT&T +800 998 2112
AT&T +800 998 2112
54 11 4894 1888
AT&T +800 998 2112
1 800 998 2112
AT&T +800 998 2112
1 800 998 2112
AT&T +800 998 2112
AT&T +800 998 2112
57 1 657 0888
Ecuador
Dominican Republic
Guatemala
Haiti
Honduras
Jamiaca
Martinique
Mexico
01 800 849CARE
North America
1 800 876 3266
4
.
TECHNICAL SPECIFICATIONS
Operating Temperature
0 to 40°C (32 to 105°F)
Operating Humidity
10 to 95% non-condensing
Power Consumption
Safety Standards
3 W maximum
UL 1950, EN 60950, CSA 22.2#950-93, IEC 950, AS/NZS 3260
Electromagnetic Compatibility
ICES-003 Class A, FCC Part 15 Class A, EN55022 Class A, VCCI Class A, AS/NZS 3548 Class A, CISPR22 Class A,
CNS 13438 Class A, Korean EMI Class A
REGULATORY NOTICES
FCC Statement
CE Statement (Europe)
This equipment has been tested and found to comply with
This product complies with the European Low Voltage
the limits for a Class A digital device, pursuant to part 15
of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference when
the equipment is operated in a commercial environment.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference to radio communications, in which case the
user will be required to correct the interference at their
own expense.
Directive 73/23/EEC and EMC Directive 89/336/EEC as
amended by European Directive 93/68/EEC.
CSA Statement
This Class A digital apparatus meets all requirements of
the Canadian interference-Causing Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les
exigences du Règlement sur le matériel brouilleur du
Canada.
VCCI Statement
Information To The User
If this equipment does cause interference to radio or tele-
vision reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following
measures:
BSMI Statement
Reorient the receiving antenna.
Relocate the equipment in relation to the receiver.
Move the equipment away from the receiver.
Plug the equipment into a different outlet so that
equipment and receiver are on different branch circuits.
If necessary, the user should consult the dealer or an
experienced radio/television technician for additional
suggestions. The user may find the following booklet
prepared by the Federal Communications Commission
helpful:
How to Identify and Resolve Radio-TV Interference
Problems
This booklet is available from the U.S. Government
Printing Office, Washington, DC 20402, Stock No.
004-000-00345-4.
In order to meet FCC emissions limits, this equipment
must be used only with cables which comply with IEEE
802.3.
5
T
LEGAL NOTICES
© 3Com Corporation, 2002. All rights reserved. No part of this
documentation may be reproduced in any form or by any means or used
to make any derivative work (such as translation, transformation, or
adaptation) without permission from 3Com Corporation.
For civilian agencies:
Restricted Rights Legend: Use, reproduction or disclosure is subject to
restrictions set forth in subparagraph (a) through (d) of the Commercial
Computer Software - Restricted Rights Clause at 48 C.F.R. 52.227-19 and
the limitations set forth in 3Com Corporation’s standard commercial
agreement for the software. Unpublished rights reserved under the
copyright laws of the United States.
3Com Corporation reserves the right to revise this documentation and to
make changes in content from time to time without obligation on the part
of 3Com Corporation to provide notification of such revision or change.
If there is any software on removable media described in this
documentation, it is furnished under a license agreement included with the
product as a separate document, in the hard copy documentation, or on
the removable media in a directory file named LICENSE.TXT. If you are
unable to locate a copy, please contact 3Com and a copy will be provided
to you.
3Com Corporation provides this documentation without warranty of any
kind, either implied or expressed, including, but not limited to, the implied
warranties of merchantability and fitness for a particular purpose. 3Com
may make improvements or changes in the product(s) and/or the
program(s) described in this documentation at any time.
UNITED STATES GOVERNMENT LEGENDS:
Unless otherwise indicated, 3Com registered trademarks are registered in
the United States and may or may not be registered in other countries.
If you are a United States government agency, then this documentation
and the software described herein are provided to you subject to the
following restricted rights:
3Com and SuperStack are registered trademarks of 3Com Corporation.
For units of the Department of Defense:
Other brand and product names may be registered trademarks or
trademarks of their respective holders.
Restricted Rights Legend: Use, duplication or disclosure by the Government
is subject to restrictions as set forth in subparagraph (c) (1) (ii) for restricted
Rights in Technical Data and Computer Software clause at 48 C.F.R.
52.227-7013. 3Com Centre, Boundary Way, Maylands Park South, Hemel
Hempstead, Herts, HP2 7YU, U.K.
ENVIRONMENTAL STATEMENTS
General Environmental Statement
End Of Life Statement
It is the policy of 3Com Corporation to be environmentally-friendly in all
operations. To uphold our policy, we are committed to:
3Com processes allow for the recovery, reclamation and safe disposal of all
end-of-life electronic components.
Establishing environmental performance standards that comply
with national legislation and regulations
Regulated Materials Statement
3Com products do not contain any hazardous or ozone-depleting material.
Environmental Statement about the Documentation
Conserving energy, materials and natural resources in all operations
Reducing the waste generated by all operations
The documentation for this product is printed on paper that comes from
sustainable, managed forests; it is fully biodegradable and recyclable, and is
completely chlorine-free. The varnish is environmentally-friendly, and the
inks are vegetable-based with a low heavy-metal content.
Ensuring that all waste conforms to recognized environmental
standards
Maximizing the recyclable and reusable content of all products
Ensuring that all products can be recycled, reused and disposed of
safely
Ensuring that all products are labelled according to recognized
environmental standards
Improving our environmental record on a continual basis
Product Registration
You can now register your Interconnect Modules (3C17716) on the 3Com web site at:
From the Product Registration page, select the Product Category “Switches”.
You cannot register the Interconnect Kit (3C17715). You can only register the individual modules with their associated serial
numbers.
Documentation Feedback
Your suggestions are very important to us. They will help make our documentation more useful to you. Please e-mail comments
about this document to 3Com at:
Please include the following information when commenting: the document title, part number and page number, if appropriate.
Part Number: DUA1771-5AAA02
Published: December 2002
6
|