INSTR4089 1006
™
Owner’s Manual
This manual is for the installation, operation, and maintenance of the
™
ScaleGard PLUS 2
Water Treatment Systems
STM150
TSR150
Installer please leave manual with end user.
Contents
Installation Requirements
Space Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Feedwater Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Water Production Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Operating Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Additional Plumbing Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation Procedure
Positioning Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Wall Mounting the Filter System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Feedwater Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Drain Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Automatic Bypass Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Storage Tank Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Point of Use Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Start-Up Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Routine Maintenance
De-pressurization Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Sediment Prefilter Cartridge Replacement. . . . . . . . . . . . . . . . . . . . . . . . 7
Chlorine Filter Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
TDS Reduction Filter Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Hardness Filter Replacement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Ion Media Filter Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Restarting and Purging the RO System. . . . . . . . . . . . . . . . . . . . . . . . . . 8
‘Push-In’ Tubing Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installation Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
System Parts List. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Important: Installation Requirements
CAUTION
To reduce the risk associated with property damage due to water
leakage:
Space
Requirement
• Installation must comply with existing state or local plumbing codes;
• Read and follow Use Instructions before installation and use of this
system.
11”
(27.9 cm)
™
Congratulations on your purchase of the CUNO Foodservice ScaleGard
PLUS 2 water treatment system. The ScaleGard PLUS 2 systems utilize
some of the world’s most advanced scale and corrosion control tech-
nologies in a compact, highly efficient package.
The ScaleGard PLUS 2 system is designed for food service equipment
with low water draw such as steam kettles and tables, combis, electric
and gas steamers, misters or other applications, where water consump-
tion does not exceed 6 gph (22.7 lph) continuous. See estimated water
production chart below.
The ScaleGard PLUS 2 STM150 is recommended where a minimal
TDS level is required for proper equipment operation. The ScaleGard
PLUS 2 TSR150 is recommended for applications where zero hardness
is required such as proofing ovens, flash steamers, injection steamers
and misters.
Before beginning the installation, take a few minutes to familiarize your-
self with the system by reviewing the entire installation, operating and
maintenance manual. It is also important to review the criteria below
to make sure that the requirements have been or will be met when the
installation is complete. Be sure to confirm that the feedwater falls within
the limits shown below. If you’re not sure if this has been done, check
with your distributor before installing the system. This is important
because failures caused by water related problems are not covered
under the system warranty.
7 3/4”
(19.7 cm)
16 11/16”
(42.4 cm)
Installation must comply with state and local plumbing requirements.
Feedwater Parameters:
Feed TDS . . . . . . . . . . . . . . . .Up to 2000 ppm (mg/L)
Hardness* . . . . . . . . . . . . . . . .< 10 grains (171 mg/L)
Iron (Fe) . . . . . . . . . . . . . . . . . .< 0.1 mg/L
Hydrogen Sulfide . . . . . . . . . . .none allowable
Feed pH . . . . . . . . . . . . . . . . . .4-11
Free chlorine . . . . . . . . . . . . . .< 2 mg/L
Manganese(Mn) . . . . . . . . . . .< 0.05 mg/L
Turbidity . . . . . . . . . . . . . . . . . .< 5 NTU
* Note: For waters over 10 grain hard, a CUNO water softener is recommended
for pretreatment. Consult CUNO technical services for correct sizing.
Electrical Requirements:
Confirm that transformer is compatible with available electrical power
supply.
ScaleGard Plus 2 - Estimated Water Production
Feedwater Temperature (°F/°C)
3
ScaleGard™ PLUS 2 Installation Schematic
Service Shut
Off Valve
(Optional)
Bypass Solenoid Valve Assy.
To Service
Manual Bypass
(Optional)
Inlet
Valve
RO Tank
3/8" RO Water Line
Supply
Water
RO System
STM 150
Bev Plus
Check Valve
TSR Systems
Manual Tank
Valve
Drain
Tank Drain/Sample Valve
If your water analysis indicates that any of these parameters are not in
range, additional pretreatment or higher frequency of maintenance may
be required. Contact your distributor for assistance. The presence of
silica or flocculants (e.g. alum or cationic polymers) in the feedwater
can cause membrane fouling and may require special chemical pre-
treatment or periodic membrane cleaning.
Additional
Plumbing
Connections
(not supplied)
Operating Parameters:
• Manual Bypass:
A manual bypass loop is
recommended to facilitate
proper service of the filter
system.
Typical TDS Cartridge Rejection..... >95%
Feed Temperature........................... 40-100°F (4-38°C)
Feed Pressure................................. 20-65 psi (138-448 kPa)*
Production.......................................... Chart on page 3 shows output in
gallons per hour at varying water
temperatures. Actual output may
vary according to feedwater
conditions and membrane variations.
• Drain Line:
A drain line is recommend-
ed to depressurize the
system during cartridge
changeout, for sanitizing
the system, and for drain-
ing the tank. Note: 10, 20,
and 40 gallon (38, 76, 151
liter) tanks are capable of
draining water in excess
of 13 gpm (49 lpm). Drain
connection must be sized
accordingly.
Note: For water temperature below 50°F (10°C) water can be
preheated to improve production rate.
• Pressure Gauge:
A pressure gauge in the
product water line is rec-
ommended to determine
the system’s performance
and when the system is
de-pressurized.
CAUTION
*To reduce the risk associated with property damage due to water
leakage:
• Do not install on systems where line pressures above 65 psi (448
kPa) may occur. Line water pressure in excess of 65 psi will re-
quire installation of a pressure regulator prior to the unit.
4
Installation Procedure
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Installation must comply with existing state or local plumbing codes;
• Read and follow Use Instructions before installation and use of this system.
Positioning Equipment
™
Prior to installing the ScaleGard PLUS 2 system, review the installation schematic (page 4) and carefully
plan the installation location for all system components. Obtain all additional hardware for plumbing connec-
tions. This will help provide proper positioning and improve serviceability during routine maintenance.
1. Position the storage tank in desired location. (See storage tank installation procedure, page 6.)
2. The ScaleGard PLUS 2 system should be installed within 15 ft (4.6 m) of the storage tank.
3. The ScaleGard PLUS 2 system must be installed within 6 ft (1.8 m) of an electrical outlet. The bypass
solenoid valve should be installed within 6 ft. (1.8 m) of the storage tank.
4. All components should be accessible and have at least 6 inches (15 cm) of clearance on all sides of
ScaleGard PLUS 2 system to facilitate servicing.
5. Access to feedwater and drain connection are also required.
Wall Mounting the Filter System
The filter system weighs approximately 30 lbs. (13.6 kg) and must be mounted securely to a rigid surface.
There are two additional mounting holes on both sides of the booster pump at the bottom of the bracket if
needed. System must be installed vertically.
1. Determine the desired mounting location and using the supplied template, mark mounting hole locations.
2. Install the three mounting screws in the marked locations, leaving about an 1/8” (3.2 mm) from the wall.
3. Remove the cartridges from the filter system by turning to the left 1/4 turn and pull down to remove.
4. Lift the filter system and align the keyhole slots over the mounting screws. Tighten the screws, securing the
filter system to the wall. Note: You may have to slide the permeate pump to the left to fully expose the
right mounting hole.
5. Install the cartridges. Note: Mate the head
icon letter with the cartridge icon letter
(S, C, M, T or H). The TDS filter (M) has
a John Guest® fitting for reject water.
Attach reject tubing to the fitting (as
Permeate
Pump
shown in drawing below).
6. Mount the transformer to the bracket with
screws provided to the top right side of the
bracket.
Transformer
Connection
Feedwater Connection
The feedwater supply line is 3/8” O.D. tubing
and should not exceed 20 ft (6.1 m) from the
main feedwater connection to the filter system.
For longer distances, 1/2” pipe or larger should
be brought to within 20 ft (6.1 m) of the system.
TDS Filter M
(RO Module)
Reject
Tube
Important: Connect to an adequate water
supply having a minimum 20 psi (138 kPa) and
maximum 65 psi (448 kPa) pressure at the inlet
of the filter system.
CAUTION
To reduce the risk associated with property
damage due to water leakage:
Plug
• Do not install on systems where line pressures
above 65 psi (448 kPa) may occur. Line water
pressure in excess of 65 psi will require instal-
lation of a pressure regulator prior to the unit.
IMPORTANT: Remove white
1. Connect a shut-off valve to main water line.
Under no circumstances should a needle
valve or self piercing valve be used.
2. Run a 3/8” O.D. line from the feedwater
connection at the main water line to the water
inlet on the filter system. Inlet connection is a
3/8” John Guest fitting.
plug from module and insert
black tube as shown. Insert
RO module into filter head
and rotate 1/4 turn until it
stops. The label should face
the front.
5
Drain Connection
Important: An approved air gap should exist between the filter system
drain lines and the drain opening to meet local plumbing codes.
1. Run a minimum 3/8” O.D. tube from the reject port to the drain.
2. The 3/8” O.D. reject tubing line may be run up to 10 ft (3 m) from the
filter system to the drain. Care must be taken not to crimp or block the
reject tubing line.
The water pressure in
the tank will increase as
the tank fills with water.
When the pressure in the
tank reaches approxi-
mately 80 psi (552 kPa)
the filter system shuts off.
When water is drawn from
the tank and the pressure
drops to approximately 60
psi (414 kPa), the filter
system will automatical-
ly turn on.
Automatic Bypass Valve
The auto-bypass valve has 3/8” MNPT inlet and outlet ports and a 6’ (183
cm) power cord that plugs into the filter system. This auto-bypass valve
should be installed between the incoming unfiltered water line to the filter
system and the water line to service after check valve. (Refer to page 4.)
Storage Tank Installation
If the tank pressure drops
to 40 psi (276 kPa) the
auto-bypass solenoid valve
will open allowing unfiltered
water to flow to service
until tank pressure reaches
approximately 60 psi (414
kPa). When the filter sys-
tem is in auto-bypass the
red light on the front of
the bracket will come on.
®
Note: Storage tanks are purchased separately. Consult the CUNO
Foodservice Price List for applicable sizes and part numbers.
1. Follow installation instructions provided with tank.
2. Check the air pressure in the tank at the valve in the top of the tank.
With the tank empty, the pressure should be 20 psi (137.9 kPa).
Adjust the air pressure as required.
3. Place the tank in the desired location. It should be placed in an area
where it will not be bumped or jarred.
4. Connect fitting and minimum 3/8” O.D. tubing to product port of the unit.
5. Run tubing from the other side of the TEE to the check valve and
on to point of use connection and bypass line. Refer to Installation
Schematic on page 4.
NOTE: TSR150-2/2A/2B
Bypass at 20psi (138
kPa) to 40 psi (276 kPa).
6. Open the ball valve on the tank by turning the handle until it is parallel
with the body of the valve.
Storage Tank
2.5 gal. (9.5 lit.)
5 gal. (19 lit.)
Diameter
9 1/16" (23 cm)
15 3/8" (39.1 cm)
16" (40.6 cm)
16" (40.6 cm)
24" (61 cm)
Height
Pipe Connection
1/4" (0.6 cm)
3/4" (1.9 cm)
1" (2.5 cm)
14 1/8" (35.9 cm)
17 3/8" (44.1 cm)
32 1/2" (82.6 cm)
57 1/2" (146.1 cm)
56 1/2" (143.5 cm)
10 gal. (38 lit.)
20 gal. (76 lit.)
40 gal. (151 lit.)
1" (2.5 cm)
1 1/4" (3.2 cm)
Point-of-Use Connections
Distance from Storage
Tank to Point of Use
Recommended Minimum
Recommended Minimum
Plastic Pipe Size
Tubing Size
1/2" O.D. (1.3 cm)
3/4" O.D. (1.9 cm)
N/R
IMPORTANT!
up to 5 ft (0-1.5 m)
5-20 ft (1.5-6.1 m)
3/8" (1 cm) Schedule 40 PVC
1/2" (1.3 cm) Schedule 40 PVC
1/2" (1.3 cm) Schedule 40 PVC
3/4" (1.9 cm) Schedule 40 PVC
The use of metallic piping
materials for high quality
water is not recommend-
ed because the water is
aggressive due to low TDS
and pH. Plastic tubing and
pipe are most suitable.
Solvent bonded plastic pipe
should be assembled care-
fully to avoid excessive glue
inside the pipe. Piping of
any type should be flushed
thoroughly before use. Be
sure piping conforms to
local plumbing codes.
20-40 ft. (6.1-12.2 m)
40-60 ft. (12.2-18.3 m)
N/R
Note: The above table is appropriate for point of use applications that require flow
rates up to 5 gpm (18.9 lpm).
Select the tubing or pipe size that will help provide adequate flow and pressure to the
point of use (i.e. Longer runs require larger tubing).
The type of tubing or pipe used must conform to local plumbing codes. Tubing or pipe
used for drinking water applications must be NSF listed or made of FDA compliant
materials.
6
Start-Up Procedure
1. Check air pressure in the storage tank, Refer to Storage Tank Installation. (page 6)
2. Close all water valves (5) in the system. (page 4)
3. Open water supply valve at the connection to the main water feed and the inlet water valve at the
unit. If manual bypass is installed it should be in the filter position.
4. Plug in transformer.
5. Plug bypass solenoid into the filter system.
6. Open the drain/sample valve. This will purge the air from the system. When you see a steady
stream of water close the drain/sample valve.
7. Open the ball valve on the storage tank.
8. Inspect all connections, fittings in the system for leaks, repair as necessary.
9. Allow storage tank to fill with RO water. NOTE: see chart for required times to fill storage tanks.
10. Open valve in water line to service and flush feed lines to each point of use.
11. System is now ready to use.
Time Required
Tank Capacity
To Fill Tank
2.5 gal. (9.5 lit.)
5 gal. (19 lit.)
10 gal. (38 lit.)
20 gal. (76 lit.)
40 gal. (151 lit.)
0.4 - 0.5 hour
0.9 - 1.1 hours
1.8 - 2.1 hours
3.6 - 4.2 hours
7.2 - 8.4 hours
@ 70°F (21°C) Water Temperature
Routine Maintenance
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Installation must comply with existing state or local plumbing codes;
• Read and follow Use Instructions before installation and use of this system.
De-pressurization Procedure
1. Turn off the inlet water valve.
2. Close the tank ball valve.
3. Open the drain line valve.
4. Wait for 30 seconds, then unplug the transformer. System is now de-pressurized.
Caution: Tank will still be under pressure.
Sediment Filter (S)
Replacement Procedure [6-12 months]
1. De-pressurize the system as instructed above.
2. Locate the sediment filter. To remove the sediment filter, turn to the left 1/4 turn. Pull down to remove
and discard it.
3. Insert the new filter by aligning the tabs with the filter head. Push up to insert and turn to the right
1/4 turn.
Chlorine Reduction Filter (C)
Replacement Procedure [6-12 months]
1. De-pressurize the system as instructed above.
2. Locate the chlorine reduction filter. To remove the chlorine reduction filter, turn to the left 1/4 turn.
Pull down to remove and discard it.
3. Insert the new filter by aligning the tabs with the filter head. Push up to insert and turn to the right
1/4 turn.
7
TDS Reduction Filter (M)
Replacement Procedure [annually]
1. De-pressurize the system as instructed above.
2. Locate the TDS reduction filter. To remove the TDS reduction filter, turn to the left 1/4 turn. Pull down
to remove.
3. Disconnect reject tubing by pushing in the white collet on plastic fitting to release the tubing (see page
9). Discard the used cartridge.
4. Remove the plug from the plastic fitting on the new cartridge and connect the reject tubing.
5. Insert the new filter by aligning the tabs with the filter head. Push up to insert and turn to the right 1/4 turn.
Note: The first full tank of water filtered after the filter is replaced should be discarded.
See start-up procedure, page 7.
Hardness Reduction Filter (H)
(ScaleGard™ PLUS 2 TSR150) Replacement Procedure [6-12 months]
1. De-pressurize the system as instructed above.
2. Locate the hardness reduction filter. To remove the hardness reduction filter, turn to the left 1/4 turn.
Pull down to remove and discard it.
3. Insert the new filter by aligning the tabs with the filter head. Push up to insert and turn to the right 1/4 turn.
Note: The first full tank of water filtered after the filter is replaced should be discarded.
See start-up procedure, page 7.
TDS Adjustment Filter (T)
(ScaleGard PLUS 2 STM150) Replacement Procedure [6 months]
1. De-pressurize the system as instructed above.
2. Locate the TDS adjustment filter. To remove the TDS adjustment filter, turn to the left 1/4 turn. Pull
down to remove and discard it.
3. Insert the new filter by aligning the tabs with the filter head. Push up to insert and turn to the right 1/4 turn.
Note: The first full tank of water filtered after the filter is replaced should be discarded.
See start-up procedure, page 7.
Restarting and Purging the RO System
1. Turn on inlet water valve.
2. Make sure the tank ball valve is closed.
3. Open the drain/sample valve
4. Plug in the transformer and wait for a steady stream of water to come from the drain/sample valve.
This will purge the air from the system.
5. Close the drain/sample valve and wait for pump to shut off (this will pressurize system). Check for leaks.
6. Open tank ball valve.
7. Plug in bypass solenoid valve.
8
‘Push-In’ Tubing Connector
(John Guest® Fitting)
To Attach Tubing
1
2
Tube
This product is outfitted with user friendly “Push
In” connectors. Proper use of the connectors is
shown in the diagrams. It is most important that
the tubing selected for use with these connectors
be of high quality, exact size and roundness, and
with no surface nicks or scratches. If it is neces-
sary to cut the tubing, use a plastic tubing cutter
or sharp razor knife. Make a clean square cut.
Should a leak occur at a ‘Push In’ connector, the
cause is usually defective tubing.
Grey Collet
Push tubing straight in as far as it will go. Tubing is secured in.
To Release Tubing
1
2
To fix leaks:
• Relieve pressure.
• Release tubing.
• Cut off at least 3/8” (9.5 mm) from end.
• Reattach tubing.
• Confirm connection is leak free.
Push in grey collet to release tubing.
Pull tubing straight out.
™
ScaleGard PLUS 2 Electrical Wiring Diagram
Bypass Pressure Switch
(Red Terminals)
Automatic
Bypass
Tank Pressure Switch
(Blue Terminal)
Bypass
Solenoid
Light
Solenoid
Fuse
Holder
Transformer
Booster Pump
™
Installation Components for ScaleGard PLUS 2 Systems*
•
•
•
•
•
•
1 pc of 3/8” Cross
• 1 pc of 1/4” x 3/8” Male Connector
• 1 pc of 1/4” NPT 0-160 pressure gauge
• 1 pc of 3/8” Female Pipe Tee
• 1 pc of 3/8”x1” Reducer Bushing
• 3/8” Tubing
1 pc of 3/8” x 1/4” Reducer Bushing
6 pcs of 1/2” x 3/8” Male Connector
1 pc of 3/8” Female Ball Valve
3/8” Nipple
1/2” Tubing (optional)
• Cutter or sharp razor knife.
* Not Provided With System
9
ScaleGard™ PLUS 2 System Part List
Item #
Description
Sediment Filter (S)
STM150
55997-01
TSR150-2
55997-01
TSR150-4
55997-01
1
2
Chlorine Reduction Filter (C)
TDS Reduction Filter (M)
Ion Media Filter (T)
55995-01
55987-07
55998-01
-
55995-01
55987-07
-
55995-01
55987-07
-
3
4
4
Hardness Reduction Filter (H)
Permeate Pump
55996-01
89-1331202
53-41401
60-1213201
53-52001
50-025
55996-01
89-1331202
53-41401
60-1213201
53-52001
50-025
5
89-1331202
53-41401
60-1213201
53-52001
50-025
6
Pump / Fuse Assembly
7
Solenoid Valve
8
Brine Flow Control
9
Bypass Solenoid Valve Assembly (60 Hz)
Bypass Solenoid Valve Assembly (50 Hz)
Transformer (115V/60 Hz)
Transformer (230V/50 Hz)
Transformer (100V/50 Hz)
Tank Switch (blue plug)
9
50-026
50-026
50-026
10
10
25-63031
25-63032
25-63030
25-15505
25-63031
25-63032
25-63030
25-15505
25-63031
25-63032
25-63030
25-15505
10
Not Shown
Not Shown
Not Shown
Bypass Switch (red plug)
Fuse, 2 Amp, 3AGC-250V
25-15503
25-61225
25-15502
25-61225
25-15503
25-61225
9
10
8
5
6
7
1
4
3
2
Front View
Front View without Front Cartridges
10
Limited Two Year Warranty
CUNO Incorporated warrants the original purchaser-con- rable new unit at no charge to the consumer or to refund the full
sumer of its Product that is free of defects in materials and purchase price. CUNO’s obligations of repair, replacement, or
workmanship. Any defect, malfunction, or other failure of the refund are conditioned upon return of the defective Product to
Product to conform to this warranty will be remedied by CUNO CUNO.
in the manner provided below.
If any Product covered hereby is actually defective within the
This Warranty, together with any warranties implied by law, terms of this Warranty, then CUNO will bear all the reasonable
shall be limited to a duration of two (2) years from the original and proper shipping and mailing charges actually incurred in the
date of purchase by the consumer.
This Warranty does not apply to defects that result from proves not to be defective within the terms of this Warranty, then
abuse, misuse, alteration or damage not caused by CUNO. all costs and expenses in connection with the processing of the
consumer’s return of the Product set forth herein. If the Product
IMPORTANT: To file a claim under this warranty you must consumer’s claim hereunder shall be borne by the consumer.
complete and mail the Warranty Registration Card supplied with
this product to CUNO at the address below within ten (10) days RESPONSIBILITY OF THE CONSUMER
of original purchase date.
The original purchaser-consumer’s sole responsibility in the
THIS WARRANTY DOES NOT COVER, AND IS INTENDED instance of a warranty claim shall be to notify CUNO of the
TO EXCLUDE ANY LIABILITY ON THE PART OF CUNO, defect, malfunction, or other manner in which the terms of this
WHETHER UNDER THIS WARRANTY OR UNDER ANY Warranty are violated. You may secure performance of obliga-
WARRANTY IMPLIED BY LAW, FOR ANY INDIRECT OR tions hereunder by (in writing):
CONSEQUENTIAL DAMAGES FOR BREACH HEREOF OR
THEREOF.
1. Identifying the Product involved (by model or serial number
or other sufficient description that will allow CUNO to determine
Note: Some states prohibit limitations on the duration of which product is defective).
implied warranties and on the exclusion of indirect or conse-
2. Specifying where, when, and from whom the Product was
quential damages; and so the limitation on implied warranties purchased.
and on incidental and consequential damages may not be appli-
cable to you.
3. Describing the nature of the defect, malfunction, or other
violation of this Warranty.
RESPONSIBILITY OF CUNO
4. Sending such notification together with the defective Product
CUNO’s responsibility under this warranty shall be to repair and $5.00 check or money order to cover postage and handling
at its expense, at no charge to the original purchaser-consumer, to:
any product that is actually defective, malfunctioning, or oth-
erwise in violation of this warranty. If CUNO for any reason
cannot repair a Product covered hereby within two (2) weeks
CUNO Incorporated,
400 Research Parkway, Meriden, Connecticut 06450, USA
after receipt of the original purchaser-consumer’s notification THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,
of a Warranty claim, then CUNO’s responsibility shall be, at its AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY
option, either to replace the defective Product with a compa- FROM STATE TO STATE
a 3M company
CUNO Incorporated
400 Research Parkway
Meriden, CT 06450, USA
CUNO and ScaleGard are trademarks of 3M Company used under license.
Toll Free: 1-888-218-CUNO
John Guest is a trademark of John Guest International Limited.
Worldwide: 203-237-5541
Fax: 203-238-8701
© 2007 3M Company. All rights reserved.
|