D4-n x 56/64 DSU DP
n x 56/64 DATA SERVICE UNIT DATAPORT
APPLICATIONS
ACT 1
NETWORK
T1
x
n 56/64
(6 x 64)
384K
VIDEO TELECONFERENCING AT 384 kB/s
D4
NETWORK
T1
x
n 56/64
(8 x 64)
BRIDGE/
ROUTER
512K
LOCAL AREA TO WIDE AREA NETWORKING AT 512 kB/s
ACT 1
ACT 1
T1
224K
224K
nx56/64
(4 X 56)
nx56/64
(4 X 56)
FILE TRANSFER APPLICATION AT 256 kB/s
SPECIFICATIONS
Data Rates:
56K Mode - 56,112, 168, 224, 280, 336, 392, 448, 504, 560,616, 672, 728, 784, 840, 896,
952, 1008, 1064, 1120, 1176, 1232, 1288, 1344 kB/s
64K Mode - 64, 128, 192, 256, 320, 384, 448, 512, 576, 640, 704, 768, 832, 896, 960, 1024,
1088, 1152, 1216, 1280, 1344, 1408, 1472, 1536 kB/s
DTE Interfaces:
Conforms to EIA 530 and CCITT V.35 specifications
DS1 Facility Interface:
Options:
Fully compliant with D4 channel bank equipment
Selection of n
(1 to 24)
Stuff Bit Location
Mode of Operation
Time Slot Arrangement
Data Polarity
(Bit 8 or 2)
(56 or 64 kB/s)
(Consecutive or Alternating)
(Normal or Inverted)
(V.35 or EIA 530)
(Internal or External)
(Enable or Disable)
(Terminated or Unterminated)
DTE Interface
Transmit Timing
Receive Outputs
Transmit Inputs
Backplane DTE Interface (Connected or Disconnected)
Faceplate Indicators:
LLB
RLB
Local Loopback
Remote Loopback
ERR Error
TD
RD
Transmit Data Active
Receive Data Active
Test Modes:
Mechanical:
Local Loopback, V.54 Remote Loopback, V.54 Remote Loopback with
Test Pattern (Test Pattern 511), Self Test
Size
-
4.4 inches high, 1.4 inches wide,
10 inches deep
Weight
-
-
12 ounces (nominal)
Mountings
D4, ADTRAN ACT 1, ADTRAN AD4-24
channel banks
Environmental
Operating Temperature
Storage Temperature
Relative Humidity
-
-
-
0° to 50°C
-40° to 85°C
Up to 95%, non-condensing
ORDERING INFORMATION
Equipment
ADTRAN Part Number
D4-n x 56/64 DSU DP
1100025L1
61100.025L1-8B
April 1992
Printed in USA