QT 120
GB
Instruction manual
GB
THANK YOU
Thank you for choosing this innovative Amcor dehumidifier. We suggest that you
keep this manual in a safe place for future reference. It describes the many benefits
and advanced features this unique product has to offer. Before you use it, you
should carefully read these instructions to maximise this product’s performance.
For over 50 years Amcor has specialised in complete indoor environmental control,
manufacturing and marketing dehumidifiers, portable air conditioners, coolers, air
purifiers, ionisers and aromatherapy scent diffusers. These world class products
incorporate the latest technological developments.
SAFETY INSTRUCTIONS
• Remove all packaging materials from the unit, keep it away from babies and
small children to avoid the danger of suffocation.
• Before inserting the plug make sure that the voltage is within the range indicated
on the rating label on the unit.
• The dehumidifier is intended exclusively for the use for which it was created.
Amcor is not responsible for any damage caused by improper use.
• The dehumidifier is safe, however as with other electrical appliances, use it with
care.
IMPORTANT!
• The unit is designed for indoor operation.
• Rating: This unit must be connected to a 220-240 V / 50 Hz earthed outlet.
• The installation must be in accordance with regulations of the country where the
unit is used.
If you are in any doubt about the electrical installation, have it checked and if
necessary modified by a qualified electrician.
• Unplug when not in use. Do not unplug by pulling the cord.
• Do not operate this product with wet hands.
• Keep out of the reach of children.
• Do not clean the unit by spraying it or immersing it in water.
• Disconnect it from the mains before cleaning the unit or any of its components.
• Always unplug before changing the carbon filter.
• Do not connect the unit to an electrical outlet using an extension cord. If an
outlet is not available, one should be installed by a licensed electrician.
3
GB
• Never operate this appliance if it is damaged or if it has a damaged cord or plug.
• Do not lead the cord over sharp edges.
• A damaged supply cord should be replaced by the manufacturer, its service agent
or a qualified person in order to avoid a hazard.
• Any service other than regular cleaning or replacing the carbon filter should be
performed by an authorized service representative. Failure to do so could result
in a loss of warranty.
The first time that you use the unit please ensure that it has been standing for
1 hours in an upright position before it is switched on.
IMPORTANT: The unit is not to be used in temperatures under 5 °C.
Do not use your dehumidifier under the following conditions:
If the power cable
wires are frayed
or cut
When small
children may be
left unattended
On a slope or
uneven surface
Close to a heat
source
This product is
not made for DIY
repair
If there is a risk of
liquid falling on
the unit
Inside unit exposed
to the weather
outdoors
In a permanent
very humid
environment
If an extension
cord is needed to
reach an outlet
Where the power
cable may be
damaged
Where it may
be damaged by
chemicals
Where there is a
risk of interference
by foreign objects
Reminder:
Waste electrical products must not be disposed of with household waste.
This product should be taken to your local recycling centre for safe treatment.
4
GB
HOW IT WORKS
Your Amcor dehumidifier draws air through two filters onto a refrigerated cold
coil. As the air in the room passes over the cold surface, moisture condenses and
collects into a removable water tank. The drier, slightly warmer air is then expelled
through the air outlet with movable louvres on top of the unit into the room
The dehumidifier controls the moisture level and protects your furniture, precious
possessions and decor from the damaging effects of excessive moisture. Your
dehumidifier is also great for drying the laundry, but not in permanent humid areas
such as the bathroom!
When the water tank is full, a micro switch automatically stops the unit and an
indicator light signals the need to empty the tank.
If preferred a continuous drainage hose connected to the bottom of the unit can be
used to drain the water.
SAVE ENERGY It takes less energy to warm dry air than damp humid air!
Dry warmer air
Condenser
(Warmed coil)
Fan
Evaporater
(Cold refrigerated coil)
Motor
Moist air
Micro switch
Compressor
Water tank
5
GB
PLACEMENT
Your AMCOR dehumidifier will begin to protect your home from the harmful effects
of excessive moisture as soon as it is turned on.
Excess moisture travels throughout your home, in the same way that cooking
smells spread to every room in the house. For this reason, the dehumidifier
should be positioned in a central and clear location so that it can draw this moist
air towards it from all over the home. A warm hallway or landing is an excellent
position for your dehumidifier. If possible, leave interior doors ajar to allow air
circulation.
Alternatively, if you have a serious problem in one area you can begin by positioning
the dehumidifier there and later moving it to a more central point.
For the most effective use, run your dehumidifier with external doors and windows
kept closed when the dehumidifier is operating.
Please note the unit should not be placed directly against a radiator or other heat
source.
When positioning your AMCOR dehumidifier, ensure that it is placed securely on a
level surface clear of any obstacle that may limit the air movement.
Your AMCOR dehumidifier is fitted with 4 wheels for easy movement.
Before you move the unit, switch it off and empty the water tank.
6
GB
CONTROL PANEL AND OPERATION
1
4
2
3
ON and humidity level control [2]
Turn the humidity control knob to the OFF position before connecting to the mains.
Set the humidity controller to the required humidity level or fully clockwise to the
maximum position for continuous working.
By rotating the knob clockwise the unit will switch off at a lower relative humidity,
i.e. it will extract more.
OFF
To turn off the unit, turn the humidity controller fully anticlockwise to OFF. Indicator
light [3] will go out.
Fan speed control [1]
This dehumidifier features a twin speed fan. To select required fan speed press fan
speed switch as shown.
In normal conditions, set the speed to high
to low
. For quieter operation, set the speed
.
Water container full indicator [4]
When the water container is full the unit will switch off and the indicator
illuminate (see "Emptying the water tank" how to proceed).
will
Remarks:
1. The unit does not run when the set humidity level is higher than the relative
humidity in the room.
2. To protect the compressor from possible damage, please wait three minutes after
turning off the unit before switching back on again.
3. The working temperature is 5 - 35 °C.
4. When the unit runs the expelled air is warmer than the room air.
5. When the unit does not start (indicator light [3] is out), check if cable and
electricity function as they should, wait for 10 minutes. If the unit then does not
start, call for assistance.
7
GB
EMPTYING THE WATER TANK
When the water tank is full, the unit will switch off automatically and the
indicator [4] will illuminate.
At this time, please empty the water tank as follows:
• Slowly slide out the tank squarely using the recess at the
bottom of the water tank as shown.
• Holding the handle inside the container, pull it slightly up and
then pull out gently for easy removal.
• Once emptied, gently push the water tank back into place
checking the
indicator light is off.
If the tank is not in the correct position the indicator light will
stay on.
Continuous drainage
Optional: For the continuous drainage facility please refer to the following:
1. Remove the water cap from the tube beneath the unit.
* Please keep the rubber plug safely for future use.
2. Fit a hose with an inside diameter of 11 mm over the drainage spout.
3. Ensure the water will always drain away freely and the hose will remain in place.
4. If you no longer need to drain continuously, take off the water tube and replace
the rubber plug. The water will then drain into the container.
Note: In very cold weather conditions, precautions should be taken to prevent the
drainage hose from freezing.
8
GB
CLEANING
Always unplug the unit from the mains before carrying out any maintenance or
cleaning the unit.
Cleaning the body
Only use a soft cloth to wipe the unit clean.
Do not use volatile chemicals, petrol, detergents, chemically treated cloths or other
harmful cleansing solutions. These could all possibly damage the cabinet.
Cleaning the air filter
This dehumidifier is equipped with a washable anti-dust filter and an active carbon
odour eating filter. These will capture most airborne pollutants like dust, smoke,
animal dander, mould spores and pollen and absorb most unwanted stale odours to
create a less irritating living environment for your enjoyment.
It is advisable to check the filters on a regular basis (at least monthly and after
storage) and clean or change as necessary following the guidelines below.
1. Extract the filter holder.
2. Unclip the frame and remove the washable and
carbon filters. Use warm water with a small
amount of medium strength detergent to wash
the filter and rinse under the cold water tap.
3. Make sure the filter is dry before replacing.
4. The black slim line active carbon filter can be
vacuum cleaned only. *To fix the active carbon
filter in position, please hook it onto the plastic
frame as indicated.
* Replace however every 3-6 months.
Note: Do not expose the filter to sunlight or other
sources of direct heat as this may cause the filter
and frame to warp.
LONG TERM STORAGE
If the dehumidifier is not used for long periods of time, follow these steps:
• disconnect the unit and wrap the power cable.
• if used, empty the water container.
• clean the unit and filter, pack it in its original packaging or cover to protect
against dust.
• store the unit in an upright position in a cool, dry place away from access by
children.
9
GB
TROUBLE SHOOTING
Never try to repair or dismantle the unit yourself. Before calling for assistance please check
the points below.
The unit doesn’t run.
Is the machine plugged in?
Is the mains power supply on?
Is the water tank full indicator on? (If so, the water tank is full or it isn’t
positioned properly).
The unit seems to
extract little water.
Are too many windows or doors open?
Is there something in the room producing lots of heat?
Is the room cold – the colder the air the less moisture the unit will extract.
Is the filter dirty?
Is the room humidity already quite low?
The unit seems to do
nothing.
Is the filter dirty?
Is the air intake or outlet blocked?
Is the room humidity already quite low?
Is the room temperature below 5 °C? The fan may run without the compressor.
Is the machine positioned unevenly so as to create vibration?
Is the floor underneath the unit uneven or loose fitting?
Is there any foreign body interfering with the unit?
Is the filter blocked?
Too noisy.
The unit’s fan doesn’t
seem to be revolving.
Is there any foreign body interfering with the unit?
Does the hose have a downward slope throughout its entire length?
Is there a kink or sharp bend in the hose?
The continuous
drainage is not working.
TECHNICAL DATA
Model
QT 120
Power supply
220 - 240 V / 50 Hz
Power consumption (at 27 °C, 90% RH)
W
195
Moisture removal (at 32 °C, 90% RH)
Refrigerant
L/24h
12
R-134A
Refrigerant load
g
180
Working temperature
Dimensions (W x D x H)
Nett weight
°C
cm
kg
5 - 35
33,7 x 28,6 x 53,5
13
Due to our continuous R+D program, specifications may change without prior notice.
For current specifications please refer to the rating label on your machine.
10
Hong Kong
Amcor Ltd
Suite 2007, Tower 6, The Gateway,
Harbour City, 9 Canton Road,
Tsim Sha Tsui, Kowloon,
Hong Kong
Tel: +852 2997 6865
Fax: +852 2997 6091
Email: [email protected]
United Kingdom
Amcor Ltd
9 Ryan Drive, West Cross Centre,
Great West Road, Brentford,
Middlesex, TW8 9ER,
United Kingdom
Tel: +44 20 8560 4141
Fax: +44 20 8232 8814
Email: [email protected]
USA
Amcor Inc.
685A Gotham Parkway, Carlstadt,
New Jersey 07072,
United States of America
Tel: +1 201 460 8100
Fax: +1 201 460 9481
Email: [email protected]
The Netherlands
Amcor B.V.
Anton Philipsweg 9-11,
1422 AL Uithoorn,
The Netherlands
Tel: +31 297 560 079
Fax: +31 297 523 062
Email: [email protected]
Israel
Amcor International Ltd
1 Sapir St.,
P.O. Box 120001,
Hertzelia Pituach,
Israel
Tel: +972 9 951 5351
Fax: +972 9 958 5650
Email: [email protected]
China
Shan Xia Industrial Development Zone,
Heng Li Town, Dongguan City,
Guangdong Province, China
Plant One - Amcor (China) Ltd
Tel: +86 769 8372 1090
Singapore
Amcor Investments (Singapore) Pte Ltd
545 Orchard Road,
Fax: +86 769 8372 1790
Email: [email protected]
#13-02, Far East Shopping Centre,
Singapore 238882
Tel: +65 6297 9881
Plant Two - Amcor Appliances Ltd
Tel: +86 769 8372 1970
Fax: +65 6297 8891
Fax: +86 769 8372 1790
Email: [email protected]
Email: [email protected]
|