Instruction Sheet
Kit # 313574
NG/LPG Fuel Conversion Kit
NG to LPG Conversion
Each generator system is delivered with a kit that includes the
plug and jet required to convert the engine to use LPG fuel. The
special insertion tool (#19618) is available through Briggs &
Stratton.
8. Lift latches up on both sides of panel to release.
NOTICE Only qualified personnel as specified in the product
installation manual should attempt Natural Gas (NG) to
Liquid Petroleum Gas (LPG) conversions. Installations
and conversions must strictly comply with all applicable
codes, industrial standards and regulations. Proper tools
and workmanship are required. Damage resulting from
unauthorized personel will void manuafacturer’s warranty.
NOTICE Ensure that the fuel supply can deliver an engine inlet
pressure of 11 to 14 inches water column.
9. Pull panel upward and out of grooves.
10. Repeat steps 8 & 9 to remove other side panel.
11. Remove 6 screws exhaust panel.
To Reconfigure for LP:
The generator is equipped with a removable roof and removable
side panels to permit simple servicing.
1. Open control panel door by inserting key into lock and turn
one quarter turn counterclockwise.
2. Set generator’s circuit breaker to OFF position.
3. Set control panel system switch to OFF.
4. Remove 15 Amp fuse from control panel.
5. Press roof latch down until roof poslightly.
12. Pull exhaust panel up and out of base.
6. Lift roof up a little ways and slide back. Lift roof off of
generator.
13. Remove two screws and pull muffler cover off.
7. Rotate 4 knobs 1/4 turn and lift divider off.
|