ROTARY HAMMER - 1”
Model 97743
SET up And OpERATing inSTRucTiOnS
Diagrams within this manual may not be drawn proportionally.
Due to continuing improvements, actual product may differ slightly from the product described herein.
®
distributed exclusively by Harbor Freight Tools .
3491 Mission Oaks Blvd., Camarillo, CA 93011
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THiS MAnuAl.
©
®
Copyright 2008 by Harbor Freight Tools . All rights reserved. No portion of this
manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor Freight Tools.
For technical questions or replacement parts, please call 1-800-444-3353.
outlets will reduce risk of electric
shock.
non-skid safety shoes, hard hat, or
hearing protection used for appropri-
ate conditions will reduce personal
injuries.
b.Avoid body contact with grounded
surfaces such as pipes, radiators,
ranges and refrigerators. There is
an increased risk of electric shock if
your body is grounded.
c.prevent unintentional starting.
Ensure the switch is in the off-po-
sition before connecting to power
source and/or battery pack, pick-
ing up or carrying the tool. Carry-
ing power tools with your finger on
the switch or energizing power tools
that have the switch on invites acci-
dents.
c.do not expose power tools to rain
or wet conditions. Water entering
a power tool will increase the risk of
electric shock.
d.do not abuse the cord. never use
the cord for carrying, pulling or
unplugging the power tool. Keep
cord away from heat, oil, sharp
edges or moving parts. Damaged
or entangled cords increase the risk
of electric shock.
d.Remove any adjusting key or
wrench before turning the power
tool on. A wrench or a key left at-
tached to a rotating part of the power
tool may result in personal injury.
e.do not overreach. Keep proper
footing and balance at all times.
This enables better control of the
power tool in unexpected situations.
e.When operating a power tool
outdoors, use an extension cord
suitable for outdoor use. Use of a
cord suitable for outdoor use reduces
the risk of electric shock.
f. dress properly. do not wear loose
clothing or jewelry. Keep your
hair, clothing and gloves away
from moving parts. Loose clothes,
jewelry or long hair can be caught in
moving parts.
f. if operating a power tool in a damp
location is unavoidable, use a
ground Fault circuit interrupter
(gFci) protected supply. Use of
a GFCI reduces the risk of electric
shock.
g.if devices are provided for the con-
nection of dust extraction and col-
lection facilities, ensure these are
connected and properly used. Use
of these devices can reduce dust-
related hazards.
3. personal safety
a.Stay alert, watch what you are do-
ing and use common sense when
operating a power tool. do not use
a power tool while you are tired
or under the influence of drugs,
alcohol or medication. A moment
of inattention while operating power
tools may result in serious personal
injury.
h.Only use safety equipment that
has been approved by an appropri-
ate standards agency. Unapproved
safety equipment may not provide
adequate protection. Eye protection
must be ANSI-approved and breath-
ing protection must be NIOSH-ap-
proved for the specific hazards in the
work area.
b.use personal protective equip-
ment. Always wear eye protection.
Safety equipment such as dust mask,
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 3
4. power tool use and care
and the work to be performed.
Use of the power tool for operations
different from those intended could
result in a hazardous situation.
a.do not force the power tool. use
the correct power tool for your
application. The correct power tool
will do the job better and safer at the
rate for which it was designed.
5. Service
a.Have your power tool serviced by
a qualified repair person using
only identical replacement parts.
This will ensure that the safety of the
power tool is maintained.
b.do not use the power tool if the
switch does not turn it on and
off. Any power tool that cannot
be controlled with the switch is
dangerous and must be repaired.
c.disconnect the plug from the
power source before making
any adjustments, changing
accessories, or storing power
tools. Such preventive safety
measures reduce the risk of starting
the power tool accidentally.
percussion and Rotary Hammer
Safety Warnings
1. Wear ear protectors. Exposure to
noise can cause hearing loss.
2. use auxiliary handles supplied
with the tool. Loss of control can
cause personal injury.
d.Store idle power tools out of
the reach of children and do not
allow persons unfamiliar with the
power tool or these instructions
to operate the power tool. Power
tools are dangerous in the hands of
untrained users.
3. Hold power tools by insulated grip-
ping surfaces when performing an
operation where the cutting tool
may contact hidden wiring or its
own cord. Contact with a ″live″ wire
will make exposed metal parts of the
tool ″live″ and shock the operator.
e.Maintain power tools. check
for misalignment or binding of
moving parts, breakage of parts
and any other condition that may
affect the power tool’s operation.
if damaged, have the power
tool repaired before use. Many
accidents are caused by poorly
maintained power tools.
4. Maintain labels and nameplates on
the tool. These carry important safety
information. If unreadable or missing,
contact Harbor Freight Tools for a
replacement.
5. Do not operate the Rotary Hammer if
any of the following problems occur:
Hammer is too hot, insulation is torn,
frayed or missing, or if excessive
sparking occurs.
f. Keep cutting tools sharp and
clean. Properly maintained cutting
tools with sharp cutting edges are
less likely to bind and are easier to
control.
6. Move the Switching Knob (24) and
Main Handle (91) only when the
g.use the power tool, accessories
and tool bits etc. in accordance
with these instructions, taking into
account the working conditions
Motor is stopped. Attempting to move
either one while the Motor is engaged
will result in abrupt bit rotation, and
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 4
can cause serious personal injury
and/or property damage.
• Properly maintain and inspect to
avoid electrical shock.
• Any power cord must be properly
grounded. Ground Fault Circuit
Interrupter (GFCI) should also be
implemented – it prevents sustained
electrical shock.
7. Do not allow the bit to stop while in
the hole. Remove the bit while it is
still rotating. If the bit stops while in
the hole, do not restart the Rotary
Hammer. Remove the bit from the
Hammer, and then remove the bit
from the workpiece.
15. Some dust created by power
sanding, sawing, grinding, drilling,
and other construction activities,
contains chemicals known [to the
State of California] to cause cancer,
birth defects or other reproductive
harm. Some examples of these
chemicals are:
8. Always keep the Power Cord (112)
and extension cord (if used) away
from the moving parts of the Rotary
Hammer.
9. Avoid unintentional starting. Prepare
to begin work before turning on the
tool.
• Lead from lead-based paints
• Crystalline silica from bricks and
cement or other masonry products
• Arsenic and chromium from
10. Do not lay the tool down until it has
come to a complete stop. Moving
parts can grab the surface and pull
the tool out of your control.
chemically treated lumber
Your risk from these exposures
varies, depending on how often you
do this type of work. To reduce your
exposure to these chemicals: work in
a well ventilated area, and work with
approved safety equipment, such as
those dust masks that are specially
designed to filter out microscopic
particles. (California Health & Safety
Code § 25249.5, et seq.)
11. When using a handheld power tool,
hold the tool with both hands to resist
starting torque.
12. Do not leave the tool unattended
when it is plugged into an electrical
outlet. Turn off the tool, and unplug
it from its electrical outlet before
leaving.
16. The warnings, precautions,
and instructions discussed in
this instruction manual cannot
cover all possible conditions and
situations that may occur. It must
be understood by the operator that
common sense and caution are
factors which cannot be built into this
product, but must be supplied by the
operator.
13. This product is not a toy. Keep it out
of reach of children.
14. People with pacemakers should
consult their physician(s) before
use. Electromagnetic fields in close
proximity to heart pacemaker could
cause pacemaker interference or
pacemaker failure. In addition,
people with pacemakers should:
• Avoid operating alone.
• Do not use with power switch locked
on.
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 5
abnormal vibration occurs, stop use
immediately.
Vibration Safety
This tool vibrates during use.
Repeated or long-term exposure to
vibration may cause temporary or
permanent physical injury, particularly
to the hands, arms and shoulders. To
reduce the risk of vibration-related
injury:
SAVE THESE
inSTRucTiOnS.
gROunding
TO pREVEnT
ElEcTRic SHOcK
And dEATH FROM
incORREcT gROunding
WiRE cOnnEcTiOn:
Check with a qualified
electrician if you are in doubt
as to whether the outlet is
properly grounded. do not
modify the power cord plug
provided with the tool. never
remove the grounding prong
from the plug. do not use the
tool if the power cord or plug
is damaged. if damaged, have
it repaired by a service facility
before use. if the plug will not
fit the outlet, have a proper
outlet installed by a qualified
electrician.
1. Anyone using vibrating tools regularly
or for an extended period should
first be examined by a doctor and
then have regular medical check-
ups to ensure medical problems are
not being caused or worsened from
use. Pregnant women or people
who have impaired blood circulation
to the hand, past hand injuries,
nervous system disorders, diabetes,
or Raynaud’s Disease should not
use this tool. If you feel any medical
or physical symptoms related to
vibration (such as tingling, numbness,
and white or blue fingers), seek
medical advice as soon as possible.
2. Do not smoke during use. Nicotine
reduces the blood supply to the
hands and fingers, increasing the risk
of vibration-related injury.
grounded Tools: Tools with Three
prong plugs
3. Wear suitable gloves to reduce the
vibration effects on the user.
4. Use tools with the lowest vibration
when there is a choice between
different processes.
5. Include vibration-free periods each
day of work.
6. Grip tool as lightly as possible (while
still keeping safe control of it). Let
the tool do the work.
3-prong plug and Outlet
1. Tools marked with “Grounding
Required” have a three wire cord
7. To reduce vibration, maintain the tool
as explained in this manual. If any
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 6
and three prong grounding plug.
The plug must be connected to a
properly grounded outlet. If the tool
should electrically malfunction or
break down, grounding provides a
low resistance path to carry electricity
away from the user, reducing the risk
of electric shock. (See 3-prong plug
and Outlet.)
applicable standards of Underwriters
Laboratories, Inc., the Canadian
Standard Association, and the
National Electrical Code. (See
Outlets for 2-prong plug.)
2. Double insulated tools may be used
in either of the 120 volt outlets shown
in the preceding illustration. (See
Outlets for 2-prong plug.)
2. The grounding prong in the plug is
connected through the green wire
inside the cord to the grounding
system in the tool. The green wire
in the cord must be the only wire
connected to the tool’s grounding
system and must never be attached
to an electrically “live” terminal. (See
3-prong plug and Outlet.)
Extension cords
1. Grounded tools require a three wire
extension cord. Double Insulated
tools can use either a two or three
wire extension cord.
2. As the distance from the supply
outlet increases, you must use a
heavier gauge extension cord. Using
extension cords with inadequately
sized wire causes a serious drop in
voltage, resulting in loss of power and
possible tool damage.
3. The tool must be plugged into an
appropriate outlet, properly installed
and grounded in accordance with all
codes and ordinances. The plug and
outlet should look like those in the
preceding illustration. (See 3-prong
plug and Outlet.)
(See Table A.) The smaller the
gauge number of the wire, the
greater the capacity of the cord. For
example, a 14 gauge cord can carry
a higher current than a 16 gauge
cord. (See Table A.)
double insulated Tools: Tools
with Two prong plugs
3. When using more than one extension
cord to make up the total length,
make sure each cord contains at
least the minimum wire size required.
(See Table A.)
4. If you are using one extension cord
for more than one tool, add the
nameplate amperes and use the sum
to determine the required minimum
cord size. (See Table A.)
Outlets for 2-prong plug
1. Tools marked “Double Insulated”
do not require grounding. They
have a special double insulation
system which satisfies OSHA
5. If you are using an extension cord
outdoors, make sure it is marked with
the suffix “W-A” (“W” in Canada) to
requirements and complies with the
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 7
indicate it is acceptable for outdoor
use.
SpEciFicATiOnS
Electrical
120 V~ / 60 Hz / 620 W
6. Make sure the extension cord is
properly wired and in good electrical
condition. Always replace a damaged
extension cord or have it repaired by
a qualified electrician before using it.
Requirements 2-Prong, Polarized Power Plug
Speed
n 750/min
0
Blows Per
Minute
2920 BPM
Capacity
1”
Chuck Type
Rotation
SDS
7. Protect the extension cords from
sharp objects, excessive heat, and
damp or wet areas.
Clockwise (non-reversible)
For drilling stone, concrete, and
other hard and brittle materials.
For chiseling.
Applications
Accessories
REcOMMEndEd MiniMuM WiRE
gAugE FOR EXTEnSiOn cORdS*
Wrench
SDS Drill Bits: 10mm/12mm
14mm/22mm
(110/220 VOlT)
EXTEnSiOn cORd
nAMEplATE
4-Point Chisel
lEngTH
Container of Grease
Carbon Brush Set
Depth Gauge Rod
Auxiliary Handle
Carrying Case
AMpERES
(at full load)
0 – 2.0
2.1 – 3.4
18
18
18
18
18
14
12
18
18
18
16
14
12
10
18
18
16
14
12
10
-
18
16
14
12
10
-
16
14
12
12
-
3.5 – 5.0
5.1 – 7.0
E194601
7.1 – 12.0
12.1 – 16.0
16.1 – 20.0
-
unpAcKing
-
-
* Based on limiting the line
voltage drop to five volts at
150% of the rated amperes.
When unpacking, check to make sure
that the item is intact and undamaged. If
any parts are missing or broken, please call
Harbor Freight Tools at the number shown
on the cover of this manual as soon as pos-
sible.
TABlE A
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
Volts Alternating Current
Amperes
V~
A
No Load Revolutions per Minute
(RPM)
n xxxx/min.
0
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 8
SET up inSTRucTiOnS
Read the EnTiRE iMpORTAnT SAFETY inFORMATiOn section at the
beginning of this manual including all text under subheadings therein
before set up or use of this product.
TO pREVEnT SERiOuS injuRY FROM AccidEnTAl
OpERATiOn:
Turn the power Switch (96) of the Rotary Hammer to its “OFF” position
and unplug the tool from its electrical outlet before assembling or
making any adjustments to the tool.
note: For additional information regarding the parts listed in the following pages, refer
to the Assembly Diagram near the end of this manual.
product Features
FiguRE A
SWiTcHing KnOB
(24)
gREASE cAp
(18)
SpRing
(41)
FROnT cOVER
(39)
pOWER SWiTcH
(96)
SElEcTOR
HAndlE HOldER
(91)
(108)
dEpTH gAugE
(106)
AuXiliARY HAndlE
(107)
BRuSH cOVER (81)
cARBOn BRuSH (82)
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 9
of the Depth Gauge at that spot.
(See Figure A.)
Tool Set up
Adjusting The Auxiliary Handle:
5. After the Depth Gauge (106) is
placed in the desired position, turn
the Auxiliary Handle (107) clockwise
until tight. The Depth Gauge should
be securely in position and should not
move. (See Figure A.)
1. The Auxiliary Handle (107) can be
placed in a variety of positions.
(See Figure A.)
2. To rotate the Auxiliary Handle
(107), turn the Auxiliary Handle
counterclockwise to loosen the band
and Foursquare Bolt (111). Once
loosened, turn the Auxiliary Handle
to the desired position. Then turn the
Handle clockwise to secure in place.
(See Figure A.)
changing The Settings:
1. The Rotary Hammer has a Switching
Knob (24) and a Selector (91) which
must be adjusted before drilling,
hammer drilling, or chiseling.
(See Figure A.)
using The depth gauge:
2. WARning! Move the Switching
Knob (24) and Selector (91)
only when the Motor is stopped.
Attempting to move the Switching
Knob or Selector while the Motor
is engaged will result in abrupt Bit
rotation and can cause serious
personal injury and/or property
damage.
1. The Depth Gauge (106) can only be
used if the Auxiliary Handle (107) is
positioned on either side or the top of
the Rotary Hammer. The body of the
Hammer will interfere with the Depth
Gauge if the Handle is in the bottom
position. (See Figure A.)
2. Loosen the Auxiliary Handle (107) by
turning the Handle counterclockwise.
(See Figure A.)
(See Figure A.)
3. cAuTiOn: When moving the
Switching Knob (24) and Main
Handle (91), make sure both actively
“click” into the desired position. If not
actively engaged, the Knob or Handle
could slip out of position resulting in
unexpected tool performance.
(See Figure A.)
3. Once the Auxiliary Handle (107) is
sufficiently loose, pull back on the
Handle Holder (108) until the hole in
the Handle is fully open.
(See Figure A.)
4. Slide the Depth Gauge (106) in to the
desired length. The tip of the Depth
Gauge on the front of the Hammer
should be the desired depth of the
hole to be drilled. The depth is from
the tip of the Drill Bit to the tip of the
Depth Gauge.
4. The front Switching Knob (24) has on
one side a symbol of a Hammer and
a Drill. On the other side is a symbol
of just a Hammer. (See Figure A.)
5. The Main Handle (91) can be pointed
either left or right. There are symbols
for a Hammer and a Drill on the left
• For example; for a 2” deep hole,
measure 2” back from the tip of the
Drill Bit. Then position the front tip
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 10
side and a symbol for a Drill only on
the right side. (See Figure A.)
3. Secure loose workpieces using a vise
or clamps (not included) to prevent
movement while working.
• To drill only: Set the Switching
Knob (24) so that the symbol of
the Hammer and Drill are facing
forward. Then turn the Selector
(91) so that it points to the right at
the Drill symbol. (See Figure A.)
4. There must not be hazardous
objects, such as utility lines or foreign
objects, nearby that will present a
hazard while working.
• To hammer drill: Set the Switching
Knob (24) so that the symbol of
the Hammer and Drill are facing
forward. Then turn the Selector
(91) so that it points to the left at the
Hammer and Drill symbol.
OpERATing inSTRucTiOnS
Read the EnTiRE iMpORTAnT
SAFETY inFORMATiOn section
at the beginning of this manual
including all text under
subheadings therein before set
up or use of this product.
(See Figure A.)
• To chisel: Set the Switching Knob
(24) so that the symbol of the
Hammer only points forward. Then inserting and Removing drill Bits:
turn the Selector (91) so that it
points left to the Hammer and Drill
symbol. (See Figure A.)
1. cAuTiOn: Always wear heavy duty
work gloves to provide protection
when inserting and removing drill bits.
Drill bits become very hot in use. Do
• nOTE: Break Point (Bull) bits and
cold chisels should be used when
not remove drill bits until the bit has
the Switches are in the hammering
completely cooled. Do not strike
position only. Using these bits/
stuck bits with a hammer as metal
chips may fly off. Always disconnect
the Power Cord (112) from its
electrical outlet when inserting and
chisels with the Switches in the
Hammer/Drill position will result in
unexpected tool performance.
removing bits and chisels.
Workpiece and Work Area Set up
2. Add a light coating of grease or
1. Designate a work area that is clean
and well-lit. The work area must not
allow access by children or pets to
prevent injury and distraction.
machine oil to the drill bit shank.
3. Pull back on the Spring (41) while at
the same time inserting and turning
the Drill Bit until it slides all the way in
the Front Cover (39). Then release
the Spring so that it returns to its
original position. nOTE: You should
not be able to move the Bit without
pulling back on the Spring again.
Make sure the Bit does not move to
ensure that it is properly locked in
place. (See Figure A.)
2. Route the Power Cord (112) along
a safe route to reach the work area
without creating a tripping hazard or
exposing the Power Cord to possible
damage. The Power Cord must
reach the work area with enough
extra length to allow free movement
while working.
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 11
4. To remove the Drill Bit, pull back on
the Spring (41) and pull out the Bit.
For optimal performance, always
keep Drill Bits and Chisels sharp.
nOTE: When drilling a hole larger
than 1-1/4” diameter, always use a
Drill Bit with four cutting edges.
(See Figure A.)
6. Store the Rotary Hammer in its
Carrying Case (105) and keep the
Case in a clean, dry, safe location out
of children’s reach.
general Operating instructions
1. Before plugging in the Power Cord
(112), insert the desired Bit. Adjust
the Auxiliary Handle (107) and Depth
Gauge (106) to the desired positions.
Then adjust the Switching Knob
(24) and Selector (91) to the desired
positions. (See Figure A.)
2. Make sure the Power Switch (96) is
in its “OFF” position. Then plug the
Power Cord (112) into the nearest
110 volt, grounded, electrical outlet.
(See Figure A.)
3. When ready to use the Rotary
Hammer, squeeze the Power Switch
(96) and allow the tool to run without
load for about one minute. This
allows the tool’s parts to become
properly lubricated. Check to see
if the running tool sounds normal.
Once the tool has been warmed up, it
is ready for use. (See Figure A.)
4. When finished using the Rotary
Hammer, release the Power Switch
(96). Wait until the tool comes to a
complete stop. Then unplug the tool
from its electrical outlet. (See Figure
A.)
5. Make sure the Drill Bit is completely
cooled. Then remove the Bit from
the tool.
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 12
only needed beginning after about 50
hours of use. (See Figure A.)
MAinTEnAncE And
SERVicing
3. TO cHAngE OR clEAn THE
cARBOn BRuSHES: It may
become necessary at sometime
to replace or clean the two
Procedures not specifically
explained in this manual
must be performed only by a
qualified technician.
Carbon Brushes (82) when Motor
performance decreases, or stops
working completely. The Carbon
Brushes are located on each side of
the Motor Housing (78). To change
or clean the Carbon Brushes:
TO pREVEnT
SERiOuS injuRY
FROM AccidEnTAl
OpERATiOn:
Turn the power Switch (96) of
the Rotary Hammer to its
“OFF” position and unplug
the tool from its electrical
outlet before performing any
inspection, maintenance, or
cleaning procedures.
• Remove the two Brush Covers
(81). Then remove the Carbon
Brushes.
• If the Carbon Brushes (82) are worn
down more than 1/2, replace both
Brushes.
TO pREVEnT SERiOuS
injuRY FROM TOOl
FAiluRE:
• If the Carbon Brushes (82) are
only dirty, they may be cleaned by
rubbing them with a pencil eraser.
do not use damaged
equipment. if abnormal noise
or vibration occurs, have the
problem corrected before
further use.
• When installing the Carbon Brushes
(82), make sure the carbon portion
of the Brushes contact the Motor
Armature, and that the springs face
away from the Armature. Also,
make sure the springs operate
1. BEFORE EAcH uSE: Inspect
the general condition of the Rotary
Hammer. Check for loose screws,
misalignment or binding of moving
parts, cracked or broken parts,
damaged electrical wiring, and any
other condition that may affect its
safe operation.
freely. After replacing or cleaning,
replace the two Brush Covers (81).
• NOTE: New Carbon Brushes (82)
tend to arc or spark when first used
until they wear and conform to the
Armature. (See Figure A.)
4. AFTER uSE: Clean external
2. AFTER EVERY 50 HOuRS OF uSE:
Use the Spanner Wrench provided to
unscrew the Grease Cap (18). Add
the Grease provided. Then, replace
and tighten the Grease Cap. nOTE:
The Rotary Hammer is pre-greased
from the manufacturer. Lubrication is
surfaces of the tool with a clean cloth.
5. WARning! if the power cord
(112) of this Rotary Hammer is
damaged, it must be replaced only
by a qualified service technician.
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 13
TROuBlESHOOTing
problem
possible causes
probable Solutions
Tool will not start.
1. No power at outlet.
1. Check power at outlet.
2. Cord not connected.
2. Check that cord is plugged in.
3. Blown fuse or tripped circuit
breaker.
3. Replace fuse or reset circuit breaker.
Motor does not
rotate with power
switch depressed.
1. Disrupted power supply.
2. Poor contact at the switch.
3. Armature or field coil burnt.
4. Broken stator coil.
1. Check power supply.
2. Repair switch.
3. Change coil.
4. Replace stator coil.
5. Carbon brushes worn out.
5. Replace carbon brushes.
Reduce drilling pressure. Decrease force.
Abnormal noise
Overload of motor caused by
from motor. Does excessive drilling pressure.
not rotate, or
rotates slowly.
Partial short
circuit.
Partial short circuit or open circuit Repair or change armature.
at armature.
Main voltage too
low.
Main power voltage too low.
Adjust main power voltage.
Gearbox becomes 1. Overload. Dull bit.
1. Reduce load. Sharpen bit.
2. Dry coils.
too hot.
2. Damp coils.
3. Incorrect fitting.
3. Repair or change armature.
4. Adjust voltage.
4. Decrease in voltage.
Sparking.
1. Short circuit or break at
armature.
1. Repair armature.
2. Surface of armature not
smooth and clean.
2. Inspect and clean armature.
3. New carbon brushes installed. 3. Normal condition. Sparking will discontinue
once new carbon brushes are worn flush
with the armature.
Follow all safety precautions whenever diagnosing or servicing the
tool. disconnect power supply before service.
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 14
pARTS liST
part #
1
description
O-Ring
Qty.
1
3
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
2
1
1
1
1
2
1
4
4
1
1
1
part #
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
description
Washer
Qty.
1
1
1
1
1
1
1
2
1
2
2
1
1
1
1
1
1
1
1
2
2
1
1
1
1
1
3
1
1
1
2
1
2
Steel Ball
Bearing
3
Cylinder
Distance Ring
Distance Cover
Front Cover
O-Ring
4
Feather Key
Piston
5
6
O-Ring
7
Spring Holder
Spring
Spring
8
Steel Column
Retainer Sleeve
O-Ring
9
Clutch
10
11
12
13
14
15
16
18
19
20
21
22
23
24
25
26
28
29
30
31
32
33
34
Third Gear
O-Ring
O-Ring
Piston
Second Hammer
Spring
Connecting Shaft
Needle Bearing
O-Ring
Name Plate
Oil Seal Ring
Gear Bearing
Distance Ring
Bearing
O-Ring
Grease Cap
Gear Housing
Name Plate
Level
Spacer
Washer
Slide Bearing
Screw
Slip Plate
Gear (No. 2)
Spring Washer
Special Nut
Bearing
Switching Knob
Position Limit
Auxiliary
Handle Seat
Handle Bracket
Screw (M5x25)
Spring
Crank Shaft
Steel Ball
Bearing
Washer
Cylinder Case
Cylinder Cap
Oil Seal
Bearing Cover
Screw (M5x60)
Gear (No. 1)
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 15
pARTS liST (cOnTinuEd)
part #
67
68
69
70
71
72
73
74
75
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
description
Washer
Qty.
1
1
1
1
1
1
1
2
2
1
1
4
4
2
2
2
2
1
2
3
1
1
1
1
part #
92
description
Left Handle Cover
Insulating Sleeve
Switch Cover
Qty.
1
4
1
1
1
2
1
1
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
Spring
93
Clutch Shaft
Center Cover
Bearing
94
96
Power Switch
97
Cord Pressing Board
ST Screw (M4x16)
Board
Armature
98
Fan Guide
99
Field Screw
Washer
101 Right Handle Cover
102 ST Screw (M5x25)
103 Screw (M5x25)
104 Dust Cover
Bearing
Housing
Washer
105 Carrying Case
106 Depth Gauge
107 Auxiliary Handle
108 Handle Holder
109 Handle Shaft
110 Pressing Board
111 Four Square Bolt
112 Power Cord
Screw (M5x50)
Brush Cover
Carbon Brush
Brush Holder
Tapping Screw
Back Cover
Fixed Screw (M5x6)
ST Screw (M4x23)
Needle Bearing
Spring Holder
O-Ring
113 Piston Pin
114 Slide Bearing
115 Stator
116 Steel Ball
Selector
plEASE REAd THE FOllOWing cAREFullY
THE MANUfACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLy
DIAgRAM IN THIS MANUAL AS A REfERENCE TOOL ONLy. NEITHER THE MANUfACTURER OR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS qUALIfIED TO MAKE ANy REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS
qUALIfIED TO REPLACE ANy PARTS Of THE PRODUCT. IN fACT, THE MANUfACTURER AND/OR
DISTRIBUTOR ExPRESSLy STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE
UNDERTAKEN By CERTIfIEDAND LICENSED TECHNICIANS, AND NOT By THE BUyER. THE BUyER
ASSUMES ALL RISK AND LIABILITy ARISINg OUT Of HIS OR HER REPAIRS TO THE ORIgINAL
PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISINg OUT Of HIS OR HER INSTALLATION
Of REPLACEMENT PARTS THERETO.
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 16
ASSEMBlY diAgRAM
104
23
106
21
22
1
24
2
105
3
4
25
111
5
6
7
110
19
26
28
29
30
31
109
18
8
9
108
113
10
32
20
107
33
11
12
34
35
13
16
14
36
15
37
38
39
40
114
41
42
48
43
49
50
44
45
46
116
47
51
60
52
53
54
55
70
61
71
62
63
31
64
65
56
72
73
74
88
54
55
57
58
59
66
68
89
67
69
90
91
115
75
103
77
78
99
94
92
79
80
87
96
97
98
86
93
85
84
101
102
112
81 82 83
REV 09e
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 17
liMiTEd 90 dAY WARRAnTY
Harbor Freight Tools Co. makes every effort to assure that its products meet high
quality and durability standards, and warrants to the original purchaser that this product
is free from defects in materials and workmanship for the period of 90 days from the date
of purchase. This warranty does not apply to damage due directly or indirectly, to misuse,
abuse, negligence or accidents, repairs or alterations outside our facilities, criminal activity,
improper installation, normal wear and tear, or to lack of maintenance. We shall in no event
be liable for death, injuries to persons or property, or for incidental, contingent, special
or consequential damages arising from the use of our product. Some states do not allow
the exclusion or limitation of incidental or consequential damages, so the above limitation
of exclusion may not apply to you. THIS WARRANTy IS ExPRESSLy IN LIEU Of ALL
OTHER WARRANTIES, ExPRESS OR IMPLIED, INCLUDINg THE WARRANTIES Of
MERCHANTABILITy AND fITNESS.
To take advantage of this warranty, the product or part must be returned to us with
transportation charges prepaid. Proof of purchase date and an explanation of the complaint
must accompany the merchandise. If our inspection verifies the defect, we will either
repair or replace the product at our election or we may elect to refund the purchase price
if we cannot readily and quickly provide you with a replacement. We will return repaired
products at our expense, but if we determine there is no defect, or that the defect resulted
from causes not within the scope of our warranty, then you must bear the cost of returning
the product.
This warranty gives you specific legal rights and you may also have other rights which
vary from state to state.
3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • (800) 444-3353
Record product’s Serial number Here:
note: If product has no serial number, record month and year of purchase instead.
note: Some parts are listed and shown for illustration purposes only, and are not
available individually as replacement parts.
SKU 97743
For technical questions, please call 1-800-444-3353.
Page 18
|