First Alert Home Security System FA148CP User Manual

FA168CPS / FA168CPSSIA  
FA148CP / FA148CPSIA  
Security Systems  
Programming Guide  
Y
READ  
ED  
ARM  
R
3
6
9
#
2
5
8
0
1
4
7
A
B
C
D
A260  
F
AR  
M
ED  
READ  
Y
OFF  
ON  
R
AWA  
Y
1
4
7
2
5
8
0
3
6
9
#
ST  
A
Y
PA  
G
E
F
A560  
K5305-5PRV5 11/08 Rev. B  
 
PROGRAMMING MODE COMMANDS  
TO ENTER PROGRAMMING MODE (using an alpha keypad connected to the control):  
A. POWER UP, then press [ ] and [#] at the same time, within 50 seconds of powering up (this method must be used if 98  
was used to exit program mode). OR  
B. Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.  
PROGRAMMING COMMANDS  
Task  
Command/Explanation  
Go to a Data Field  
Entering Data  
Press [] + [Field Number], followed by the required entry.  
When the desired field number appears, simply make the required entry. When the last entry  
for a field is entered, the keypad beeps three times and automatically displays the next data  
field in sequence. If the number of digits that you need to enter in a data field is less than the  
maximum digits available (for example, the phone number fields *41, *42), enter the desired  
data, then press [] to end the entry. The next data field number is displayed.  
Press [#] + [Field Number].  
Review a Data Field  
Data will be displayed for that field number. No changes will be accepted in this mode.  
Deleting an Entry  
Press [] + [Field Number] + []. (Applies only to fields 40 thru *46, *94, and pager fields)  
Press 96. Initializes download ID and subscriber account number.  
Press 97. Sets all data fields to original factory default values.  
Press 56. Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800  
RF transmitters.  
Initialize Download ID  
Reset Factory Defaults  
Zone Programming  
Function Key Programming  
Zone Programming  
(Expert Mode)  
Press 57. Unlabeled keypad keys (known as ABCD keys) for special functions  
Press 58. Same options as *56 mode, but with fewer prompts. Intended for those familiar  
with this type of programming, otherwise *56 mode is recommended.  
Output Device Mapping  
Output Programming  
Zone List Programming  
Alpha Programming  
IP/GSM Programming  
Exit Program Mode with  
installer code lockout  
Press 79. Assign module addresses and map individual relays/powerline carrier devices  
Press 80. 4229 or 4204 Relay modules, Powerline Carrier devices, or on-board triggers  
Press 81. Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc.  
Press 82. Zone alpha descriptors  
Press 29. For programming the IP/GSM options.  
Press 98. Exits programming mode and prevents re-entry by: Installer Code + 8 + 0 + 0.  
To reenter programming mode, the system must be powered down, then powered up. Then  
use method A above. See field *88 for other *98 Program mode lockout options.  
Exit Program Mode  
Press 99. Exits program mode and allows re-entry by: Installer Code + 8 + 0 + 0 or method A  
above.  
Enter code + [#] +64. Create schedules to automate various system functions.  
Installer code + [#] + 1 (perform while system is disarmed and in normal mode)  
Scheduling Mode  
Site-Initiated Download  
AVS QUICK PROGRAMMING COMMANDS (for AAV sessions using the AVS system)  
For controls with the following firmware revision levels, these commands automatically configure the control for AVS  
operation. FA148CP = version 6.0 or higher; FA168CPS = version 7.0 or higher  
installer code + [#] + 03: enable AVS operation  
installer code + [#] + 04: enable AVS operation and enable panels sounds on the AVST speaker  
installer code + [#] + 05: remove all programming options that were set if [#] + 03 quick command was performed  
installer code + [#] + 06: remove all programming options that were set if [#] + 04 quick command was performed  
Refer to the AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS section for details on the specific options  
that are set with each command, depending on the control used.  
To select the AAV session communication path (phone line/communication device), see field 55 Dynamic Signaling Priority.  
To enable AAV operation, use 91 Options field (option 4).  
Special Messages  
OC = OPEN CIRCUIT (no communication between Keypad and Control).  
EE or ENTRY ERROR = ERROR (invalid field number entered; re-enter valid field number).  
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds.  
This will revert to a “Ready” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this  
delay by pressing [#] + [0].  
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear after  
you correct the programming.  
IMPORTANT: The Real-Time Clock must be set before the end of the installation. See procedure in the Setting  
the Real-Time Clock section of this manual.  
– 3 –  
 
DATA FIELD PROGRAMMING FORM  
FA148CP/FA148CPSIA  
only to  
controls, except entries shown in dashed boxes, which apply  
Entries apply to the FA168CPS/FA168CPSSIA and  
the FA168CPS (partition entries) and are not applicable to the FA148CP/FA148CPSIA controls  
/FA168CPSSIA  
SIA-Compliant Controls: Where noted, certain fields have special settings when used with the FA168CPSSIA and FA148CPSIA SIA-Compliant  
controls (indicated by in reverse type and heavy borders for easy identification).  
.
SIA-Compliant Controls  
Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.  
SIA Guidelines for Non-SIA-Compliant Controls: Notes in certain fields give instructions for programming the FA168CPS/FA148CP for False  
Alarm Reduction (these controls can be programmed to reduce false alarms, but they are not fully SIA compliant).  
SYSTEM SETUP ( 20– 29)  
Installer Code  
20  
|
|
|
[4112]  
Enter 4 digits, 0-9  
The Installer Code is used to assign the 4-digit Master Security Code.  
The Installer Code can perform all system functions except it cannot  
disarm the system unless it was used to arm the system.  
Quick Arm Enable  
21  
[0,0]  
0 = no  
Part. 1  
Part.2  
1 = yes  
If enabled, users can press the [#] followed by an arming key to arm  
the system instead of using a security code. The security code is  
always needed to disarm the system.  
RF Jam Option  
0 = no RF Jam detection  
1 = send RF Jam report  
22  
[0]  
If enabled, a report is sent if the system detects an RF jamming signal.  
UL: must be 1 if wireless devices are used  
Quick (Forced) Bypass  
23  
[0,0]  
0 = no quick bypass  
Part. 1  
Part. 2  
1 = allow quick bypass (code + [6] + [#] )  
Zones bypassed by this function will be displayed after the bypass is  
initiated.  
UL: must be 0  
RF House ID Code  
24  
26  
|
|
|
[00,00,00]  
00 = disable all wireless keypad use  
01–31 = using 5827, 5827BD or  
5804BD keypad  
P1  
P2  
Common  
The House ID identifies receivers and wireless keypads. If a 5827 or  
5827BD Wireless Keypad or 5804BD Transmitter is being used, a  
House ID code must be entered and the keypad set to the same  
House ID. You can assign RF house ID for each partition  
Chime By Zone  
[0]  
0 = no (chimes on fault of any entry/exit  
or perimeter zone when chime  
mode on)  
If “yes,” list chime zones on zone list 3 using *81 Menu mode.  
If enabled, you can define the specific zones intended to chime when  
faulted while the system is in Chime mode.  
1 = yes (chimes on fault of specific  
zones listed in chime zone list 3  
when Chime mode on)  
Powerline Carrier Device (X–10)  
House Code  
27  
28  
[0]  
Powerline Carrier devices require a House ID, identified in this field.  
Program Powerline Carrier devices in interactive modes 79, 80 and  
0 = A  
1 = B  
2 = C  
3 = D  
4 = E  
5 = F  
6 = G  
7 = H  
8 = I  
#11 = L  
#12 = M  
#13 = N  
#14 = O  
#15 = P  
81.  
UL: not for fire or UL installations  
9 = J  
#10 = K  
Access Code For Phone Module  
00 = disable  
1st digit: enter 1–9  
2nd digit: enter # + 11 for "", or # + 12  
for "#".  
|
[00]  
(Partition 1 only)  
You must assign a 2-digit access code for the 4286 Phone Module, if  
used. Example: If desired access code is 7, then 7 is the first entry,  
and [#] + 11 (for ) is the second entry.  
NOTE: A 0 in either digit disables the phone module.  
UL: must be 00 for UL Commercial Burg. installations  
29 Enable IP/GSM – Communication Device Menu Mode (pass-through programming)  
This is a Menu Mode command, not a data field, for programming IP/GSM communication device options. See 29 Menu  
Mode section later in this document.  
– 4 –  
 
Single Alarm Sounding Per Zone  
0 = unlimited sounding  
1 = one alarm sounding per zone  
31  
[0]  
If enabled, limits alarm sounding on the bell output to once per zone  
per armed period.  
SIA-Compliant Controls: If “0”  
selected, “alarm sounding per zone”  
will be the same as the “number of  
reports in armed period” set in field  
*93 (1 if one report, 2 if 2 reports,  
unlimited for zones in zone list 7).  
Fire Alarm Sounder Timeout  
0 = sound stops at timeout selected in  
field 33  
32  
33  
34  
[0]  
This control complies with NFPA requirements for temporal pulse  
sounding of fire notification appliances. Temporal pulse sounding for a  
fire alarm consists of the following: 3 pulses – pause – 3 pulses – pause – 3  
pulses.  
1 = no timeout; sounds until manually  
turned off  
UL: must be 1 for fire installations  
Alarm Sounder (Bell) Timeout  
[1]  
0 = none  
1 = 4 min  
2 = 8 min  
3 =12 min  
4 = 16 min  
This field determines whether the external sounder will shut off after  
time allotted, or continue until manually turned off.  
UL: For residential fire alarm installation, must be set for a minimum of 4 min  
(option 1); for UL Commercial Burglary installations, must be minimum 16 min  
(option 4)  
Exit Delay  
00 - 96 = 0 - 96 secs  
97 = 120 secs  
|
|
[60,60]  
Part. 1  
Part. 2  
The system waits the time entered before arming entry/exit zones. If  
the entry/exit door is left open after this time expires, an alarm will  
occur. Common zones use same delay as partition 1.  
SIA Guidelines: minimum exit delay is 45 seconds  
Common zones use part. 1 delay.  
UL installations: For UL Commercial Burglar Alarm and UL Residential Burglar  
Alarm installations with line security, total exit time must not exceed 60  
seconds.  
SIA-Compliant Controls:  
45 - 96 = 45 - 96 secs; 97 = 120 secs  
NOTE: Entries less than 45 will result  
in a 45-second delay.  
Entry Delay #1  
00 - 96 = 0 - 96 seconds  
97 = 120 secs  
98 = 180 secs  
99 = 240 secs  
35  
|
|
[30,30]  
Part. 1  
Part. 2  
Upon entering, the system must be disarmed before the time entered  
expires, otherwise it sounds an alarm.  
Common zones use same delay as part 1.  
SIA Guidelines: minimum entry delay is 30 seconds  
SIA-Compliant Controls:  
For UL Residential Burglary Alarm installations, must be set for a maximum of  
30 seconds; entry delay plus dial delay should not exceed 1 min. For UL  
Commercial Burglar Alarm, total entry delay may not exceed 45 seconds.  
Upon entering, the system must be disarmed before the time entered expires,  
otherwise it sounds an alarm.  
30-96 = 30 - 96 secs; 97 = 120 secs;  
98 = 180 secs; 99 = 240 secs  
NOTE: Entries less than 30 will result  
in a 30-second delay.  
Entry Delay #2  
36  
37  
|
|
[30,30]  
See *35 Entry Delay 1 for entries.  
Part. 1  
Part. 2  
Audible Exit Warning  
0 = no; 1 = yes  
[1,1]  
Part. 1  
Part. 2  
Warning sound consists of slow continuous beeps until the last 10  
seconds, and then it changes to fast beeps. Sound ends when exit time  
expires.  
SIA-Compliant Controls: Feature  
always enabled; field does not exist.  
SIA Guidelines: must be enabled  
Confirmation Of Arming Ding  
0 = no  
1 = yes (wired keypads and RF)  
2 = yes, RF only (except 5827,  
5827BD)  
38  
[0,0]  
Part. 1  
Part. 2  
Confirmation of arming is 1/2-sec external sounder “ding.”  
If 1 selected, ding occurs when closing report is sent if open/close  
reporting is enabled, or at the end of Exit Delay. If 2 selected, ding  
occurs upon reception of the wireless arming command.  
UL: must be 1 for UL Commercial Burglar Alarm inst.  
– 5 –  
 
When the system powers up armed, an alarm will occur 1 minute after  
arming if a zone is faulted. Note that if the previous state was armed  
Away or Stay, the system ignores sensor changes for 1 minute, which  
allows sensors such as PIRs to stabilize.  
UL: must be 1  
SIA Guidelines: must be 1  
Power Up In Previous State  
0 = no, always power up disarmed;  
1 = yes, power up in previous state  
39  
SIA-Compliant Controls: Feature  
always enabled; field does not exist.  
DIALER PROGRAMMING ( 40 – 42)  
PABX Access Code or Call  
Waiting Disable  
Enter up to 6 digits.  
40  
|
|
|
|
|
Call Waiting: If the subscriber’s phone service has “call waiting” (and  
is not using PABX), enter “*70” (“# + 11”) plus “# + 13” (pause) as the  
PABX entry to disable “call waiting” during control panel calls. If the  
subscriber does not have “call waiting” and is not using PABX, make  
no entry in this field.  
To clear entries, press 40.  
If call waiting is used, enter call waiting  
disable digits “(#+11) 70” plus “# +  
13” (pause).  
NOTES:  
SIA-Compliant Controls: If call  
waiting is used, enter call waiting  
disable digits as described above,  
and also set Call Waiting Disable  
option in field *91.  
1. The call waiting disable feature cannot be used on a PABX line.  
2. Using Call Waiting Disable on a non-call waiting line will prevent  
successful communication to the central station.  
Primary Phone No.  
Secondary Phone No.  
Do not fill unused spaces.  
41  
42  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0–9  
#+11 for ' '  
respectively  
.
Enter up to 20 digits. To clear entries, press 41 or 42  
Enter the respective phone numbers. If fewer than the maximum digits  
entered, exit the field by pressing []. The next data field number is displayed.  
#+12 for '#'  
#+13 for a 2-second pause  
43  
44  
45  
46  
| | | / | | | | |  
| | | / | | | | |  
[FFFFFFFFFF]  
[FFFFFFFFFF]  
Partition 1 Primary Acct. No.  
Part. 1 Secondary Acct. No.  
Partition 2 Primary Acct. No.  
|
|
|
|
|
|
/
/
|
|
|
|
|
|
|
|
|
|
[FFFFFFFFFF]  
[FFFFFFFFFF]  
Partition 2 Secondary Acct. No.  
Enter 4 or 10 digits, as chosen in *48  
Report Format. Enter digits 0–9; #+11  
for B; #+12 for C; #+13 for D; #+14 for  
E; #+15 for F.  
Enter [] as the fourth digit if a 3-digit account number (for 3+1 dialer  
reporting format) is used. Enter 0 as the first digit of a 4-digit account  
number for 0000-0999. E.g., For Acct. B234, enter: #+11 + 2 + 3 + 4  
To clear entries in a given field, press *43*, *44*, *45*, or *46* based  
on the field being programmed  
Phone System Select  
47  
48  
[1]  
If Cent. Sta. is not on a WATS line:  
0=Pulse Dial; 1=Tone Dial  
Select the type of phone service for the installation.  
If Cent. Sta. is on a WATS line:  
2 = Pulse Dial ; 3 = Tone Dial  
Report F ormat  
[77]  
0 = 3+1, 4+1 ADEMCO L/S STANDARD  
1 = 3+1, 4+1 RADIONICS STANDARD;  
2 = 4+2 ADEMCO L/S STAND.  
3 = 4+2 RADIONICS STANDARD  
5 = 10-digit ADEMCO CONTACT ID®  
REPORTING  
primary  
secondary  
Select the format for primary/secondary phone numbers  
6 = 4+2 ADEMCO EXPRESS  
7 = 4-digit ADEMCO CONTACT ID®  
REPORTING  
8 = 3+1, 4+1 ADEMCO L/S EXP.;  
9 = 3+1, 4+1 RADIONICS EXP  
Split/Dual Reporting  
0 = Standard/backup reporting only (all  
to primary)  
49  
[0]  
Backup Reporting: All reports are sent only to the primary number  
unless unsuccessful after 8 attempts. If unsuccessful, the system will  
make up to 8 attempts to send all reports to the secondary number. If  
still unsuccessful after the 16 attempts, the system displays the  
“COMM. FAILURE” message (FC for fixed-word displays).  
1-5 = see table at right  
Primary Phone No.  
2nd Phone No.  
Others  
Open/Close, Test  
All  
All  
1 = Alarms, Restore, Cancel  
2 = All except Open/Close, Test  
3 = Alarms, Restore, Cancel  
4 = All except Open/Close, Test  
5 = All  
– 6 –  
 
Burglary Dialer Delay  
Delay Time:  
0 = no delay  
50  
[2,0]  
Delay  
Time  
SIA-Compliant Controls:  
Delay Disable  
1 = 15 seconds  
2 = 30 seconds  
3 = 45 seconds  
Provides delay of “BURGLARY ALARM” report to the central station,  
which allows time for the subscriber to avoid a false alarm transmission.  
This delay does not apply to zone type 24 alarms (silent burglary) or to  
24-hour zone types 6, 7, and 8 (silent panic, audible alarm, auxiliary  
alarm), which are always sent as soon as they occur.  
UL: Delay Time must be 0  
SIA Guidelines: delay must be minimum of 15 seconds  
SIA-Compliant Controls:  
Delay Time:  
1 = 15 seconds  
2 = 30 seconds  
3 = 45 seconds  
Delay Disable:  
0 = use delay set in entry 1  
1 = dial delay disabled for zones  
listed in zone list 6 (use zone list 6  
to enter those zones that require  
dial delay to be disabled; these  
zones ignore the setting in entry 1)  
UL: Dial delay plus entry delay must not  
exceed one minute; use zone list 6 to  
disable dial delay from appropriate zones,  
if necessary.  
SESCOA/Radionics Select  
0 = Radionics (0-9, B-F)  
1 = SESCOA (0-9 only reporting)  
53  
54  
[0  
Enter 0 for all non-SESCOA formats.  
Dynamic Signaling Delay  
0 = no delay (both signals sent)  
1 = 15 secs  
[0]  
Select delay from 0 to 225 secs, in 15-sec increments.  
Intended for reporting via a communication device on the ECP bus  
(LRR). This field lets you select the time the panel should wait for  
acknowledgment from the first reporting destination (see 55) before it  
attempts to send a message to the second destination. Delays can be  
selected from 0 to 225 seconds, in 15-second increments. This delay is  
per message. If 0 is entered in this field, the control panel will send  
redundant reports to both Primary Dialer and LRR.  
2 = 30 secs, etc.  
UL: If using line security, must be 0.  
Reports will be sent to both the dialer and  
the communication device.  
Dynamic Signaling Priority /  
55  
[0]  
AAV Path Select  
0 = Primary Dialer first / AAV via phone  
line  
1 = Communication Device (LRR) first /  
AAV via communication device  
path (see AAV Path Select  
paragraph at right)  
This field selects the primary communication path for reporting (dialer  
or communication device) of primary phone number events (see 49  
Split/Dual Reporting) and selects the communication path used for  
AAV sessions (phone line or communication device path). Use 29  
IP/GSM menu mode to enable the communication device being used.  
For Dynamic Signaling Priority:  
for messages as follows:  
Select the initial reporting destination  
Primary Dialer First selected (0):  
If acknowledged before delay expires (see 54), then message will  
not be sent via LRR.  
For UL Commercial Burglary installations  
that use a DACT and LRR, this field must  
be 0.  
If not acknowledged before delay expires, message is sent to both  
the Primary Phone No. and via LRR.  
Long Range Radio First selected (1):  
If acknowledged before delay expires, then message will not be sent  
to the primary dialer.  
If not acknowledged before delay expires, message is sent to both  
the Primary Phone No. and via LRR.  
For AAV Path Select:  
If using the UVS system or AVS system with non-ECP connection,  
option 0 must always be used.  
If using the AVS system with ECP connection, either option (0 or 1)  
may be used, but note the following:  
IMPORTANT: If option “1” is selected, a 2-way voice (AAV) device  
compatible with the communication device path must be used (ex.  
GSMV communicator). When selected, AAV sessions always occur  
via the GSMV communicator, even if reporting reverts to phone line  
backup due to GSMV communicator path reporting failure.  
56, 57, 58 Menu Modes  
These are Menu Mode commands, not data fields, for Zone Programming, Function Key Programming, and Expert Mode  
Zone Programming respectively. See page 3 and respective sections later in this document.  
– 7 –  
 
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (59 thru 68, *70 thru 76, and 89):  
For 3+1 or 4+1 Standard Format: Enter a code in the first box:  
1–9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.  
A 0 (not #+10) in the first box disables a report. A 0 (not #+10) in the second box results in advance to the next field.  
For Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.  
A 0 (not #+10) in the second box will eliminate the expanded message for that report. A 0 (not #+10) in both boxes will disable  
the report.  
For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the first box, to enable zone to report (entries in the  
second boxes are ignored).A 0 (not #+10) in the first box disables the report.  
UL: Report codes are required in fields *61, *65, *71, *72, for UL Commercial Burglar Alarm installations.  
Report codes are required in fields *60, *62, *63, *64, *70, *73, *74, *75, *76, for UL Commercial Burglar Alarm installations and required for  
Residential Fire Alarm installations  
SYSTEM STATUS REPORT CODES ( 59– 68)  
Exit Error Alarm Report Code  
See above for entries.  
59  
[0]  
After arming the system, entry/exit and interior zones remaining open  
after exit delay expires cause an alarm sound at the keypad and  
external sounder (keypad also displays “EXIT ALARM”), and entry  
delay begins. Disarming before the end of the entry delay stops the  
alarm sounding and no message is sent to the central station. The  
keypad will display “CA” (fixed-word) or “ALARM CANCELED” (alpha  
display).  
SIA-Compliant Controls:  
[1] Always enabled.  
If the system is not disarmed before entry delay expires, an “EXIT  
ALARM” message (SIA-Compliant Controls: also zone alarm  
message) will be sent to the central station. The keypad will display “EA”  
(fixed-word ) or “EXIT ALARM” (alpha display), and alarm sounding  
continues until the system is disarmed (or timeout occurs).  
An Exit Alarm condition will also result if a fault occurs in an exit or  
interior zone within 2 minutes following the end of the exit delay, and an  
“EXIT ALARM” message will be sent to the central station (except for  
SIA-Compliant Controls, see field *69 Recent Closing report). With  
Contact ID format, the message will contain the zone number  
and error code 374 (“ALARM–EXIT ERROR”).  
Trouble Report Code  
See above for entries.  
60  
|
[10]  
Sent if a zone has a trouble condition.  
See UL System Reporting Note above *59.  
Bypass Report Code  
See above for entries.  
61  
|
[00]  
Sent when a zone is manually bypassed.  
See UL System Reporting Note above *59.  
AC Loss Report Code  
See above for entries.  
62  
|
[10]  
Timing of this report is random with up to a 4-hour delay. If AC restores  
before the report goes out, there is no “AC LOSS” report.  
See UL System Reporting Note above *59.  
Low Bat Report Code  
See above for entries.  
63  
|
[10]  
Sent when the system’s backup battery has a low-battery condition.  
See UL System Reporting Note above *59  
Test Report Code  
64  
|
[00]  
See above for entries.  
Periodic Test Report Scheduling  
Commands:  
Sent periodically to test that the communicator and phone lines are  
operational.  
Frequency of report is set in Scheduling mode (event 11) or by the key  
commands listed at left:  
Each mode sets schedule 32 (FA168CPS) or schedule 08 (FA148CP)  
to the stated repeat option; first test report sent 12 hours after  
command.  
See System Reporting UL Note above *59.  
† NOTE: Make sure the Real-Time Clock is set to the proper time before  
entering the test report schedule command to ensure that test reports are sent  
when expected. (see Setting the Real-Time Clock section)  
installer code +[#] + [0] + 0 = report  
every 24 hrs  
installer code +[#] + [0] + 1 = report once  
per week  
installer code +[#] + [0] + 2 = report  
every 28 days  
Open Report Code  
See above for entries.  
65  
[0,0,0]  
Part. 1  
Part. 2  
Common  
Sent upon disarming the system in the selected partitions.  
See UL System Reporting Note above *59.  
– 8 –  
 
Arm Away/Stay Rpt Code  
See above for entries.  
66  
[0,0,0,0,0,0]  
Away Stay  
Part. 1  
Away Stay  
Part. 2  
Away Stay  
Common  
This option allows for independent programming of Away and Stay  
reports for each partition, including the common lobby.  
NOTE: “OPEN” reports are not sent if the associated closing report is  
not enabled.  
RF Trans. Low Bat Report Code  
67  
68  
|
[00]  
See above for entries.  
Sent when a transmitter low-battery condition exists.  
UL: must be enabled if wireless devices are used  
Cancel Report Code  
See above for entries.  
|
[00]  
Sent upon disarming the system after an alarm condition was reported.  
SIA-Compliant Controls: [10]  
Report enabled.  
Recent Closing Report Code  
Not applicable to FA148CP/FA168CPS  
See above for entries.  
69  
|
[11]  
SIA-Compliant Controls: Field does not apply to other controls.  
Similar to the Exit Error condition described in field *59, but occurs if  
any burglary zone is faulted within two minutes after the initial exit  
delay expires. Disarming the system within the two minutes stops the  
alarm sound and displays "ALARM CANCELED " or "CA" and faulted  
zone number. No message is sent to the Central Monitoring Station.  
If the system is not disarmed within two minutes, the alarm sound  
continues and a “recent closing” and a “zone alarm” message are  
sent to the Central Monitoring Station (after dial delay expires).  
SIA-Compliant Controls:  
Always enabled.  
RESTORE REPORT CODES ( 70 – 76)  
Alarm Restore Rpt Code  
See above for entries.  
70  
[0]  
Alarm restore signals indicate that respective alarm zone(s) are no  
longer faulted. Alarm restore reports are sent to the central station at  
bell timeout (field *33), if the zone(s) in alarm are actually restored to a  
non-faulted state at that time. Otherwise, alarm restore report(s) for  
respective alarm zones are sent when the system is disarmed.  
See UL System Reporting Note above *59.  
If Reports Per Armed Period Per Zone (*93) is also programmed, the  
system will report alarm and restore codes as described above until the  
“Reports Per Armed Period” count is reached. Disarming and rearming  
will reset the “Reports Per Armed Period” count.  
Trouble Restore Rpt Code  
See above for entries  
71  
|
[00]  
Sent when a trouble in a zone is restored and code + OFF performed.  
See UL System Reporting Note above *59.  
Bypass Restore Rpt Code  
See above for entries.  
72  
|
[00]  
Sent when a zone that has been bypassed is unbypassed.  
See UL System Reporting Note above *59.  
AC Restore Rpt Code  
See above for entries.  
73  
|
[00]  
Sent after AC power has been restored after an AC power outage.  
See UL System Reporting Note above *59.  
Low Bat Restore Rpt Code  
See above for entries.  
74  
|
[00]  
Sent after a system low-battery condition is restored to normal.  
See UL System Reporting Note above *59.  
RF Trans. Lo Bat Rst Rpt Code  
See above for entries.  
75  
|
[00]  
Sent when a transmitter’s low battery condition is restored (i.e., new  
battery installed).  
UL: must be enabled if wireless devices are used. See UL System Reporting  
Note above *59.  
Test Restore Rpt Code  
See above for entries.  
76  
|
[00]  
This is sent when the Test mode is exited or upon timeout (4hrs).  
See UL System Reporting Note above *59.  
– 9 –  
 
OUTPUT AND SYSTEM SETUP ( 77 – 93)  
Daylight Savings Time Start/End  
Month  
0 = Disabled  
1-9 = January-September  
(1 = Jan, 2 = Feb, etc)  
#+10 = October  
#+11 = November  
#+12 = December  
77  
|
[3][11]  
Enter the start and end month for daylight savings time, if applicable to  
the region.  
Daylight Savings Time Start/End  
78  
|
[2][1]  
Weekend  
0 = disabled  
1 = first  
Enter the start and end weekend for daylight savings time, if applicable  
to the region.  
4 = fourth  
5 = last  
2 = second  
3 = third  
6 = next to last  
7 = third to last  
79, *80, *81, *82 Menu Modes  
These are Menu Mode commands, not data fields, for Output Device Mapping, Output Programming, Zone List Programming,  
and Alpha Programming respectively. See page 3 and their respective sections for procedures.  
Auto Stay Arm  
0 = no  
84  
[FA168CPS: 3; FA148CP: 1]  
If enabled, the system will automatically change AWAY mode to STAY  
mode if the entry/exit door is not opened and closed within the exit  
delay time after a user arms in AWAY mode from a wired keypad (non-  
RF device). An Opening report followed by an Armed Stay report is  
sent to the Central Station.  
1 = partition 1 only  
2 = partition 2 only  
3 = both partitions  
If the door is opened and closed within the exit delay period, the  
system remains in AWAY mode.  
Any RF device that arms the system AWAY overrides this feature and  
the system remains armed AWAY.  
Cross Zone Timer  
85  
86  
[0]  
0 = 15 secs 6 = 2-1/2 min #+12 = 8 min  
Sets the maximum amount of time in which two cross zones must be  
tripped in an armed system to send an alarm message to the Central  
1 = 30 secs 7 = 3 min  
2 = 45 secs 8 = 4 min  
3 = 60 secs 9 = 5 min  
4 = 90 secs #+10 = 6 min  
#+13 = 10 min  
#+14 = 12 min  
#+15 = 15 min Station. If only one cross zone is tripped during this time, a trouble  
message (CID code 380) for that zone is sent to the Central Station.  
#+11 = 7 min  
This option not for use in UL installations.  
5 = 2 min  
Assign cross zones on zone list 4, using *81 Menu mode.  
NOTE: Cross zoning takes effect only after Exit Delay expires.  
Cancel Verify Keypad Display  
0 = no “alarm canceled” display  
1 = display “Alarm Canceled” when  
system is disarmed after an alarm has  
occurred. (To clear the “ALARM  
CANCELED” display, the user must  
enter the security code + OFF again.)  
[1]  
This feature causes a “ALARM CANCELED” display on the LCD  
keypad under the following conditions:  
After the kissoff of the cancel message to the Central Station,  
indicating a successful transmission.  
When an alarm is successfully canceled before the Central Station  
received the Alarm message. E.g., if an alarm is incorrectly triggered  
and the user presses code + OFF before the dial delay time has  
expired, the message will never go out to the CS.  
When the Cancel report is not enabled and the system is disarmed:  
a. before dialer delay expires (alarm report not sent) message  
“Alarm Canceled” is displayed.  
b. after dialer delay expires message “Alarm Canceled” is not  
displayed  
.
Misc. Fault Delay Time  
87  
[0]  
0 = 15 secs 6 = 2-1/2 min #+12 = 8 min  
(used with Configurable Zone Types “digit 6”)  
Used with zones assigned to a configurable zone type with fault delay  
#+15 = 15 min on (configurable zone type digit “6”), and sets a zone response time of  
15 seconds to 15 min. It can be assigned to zones with sensors that  
provide a trouble indication when an oil tank is low, or similar  
applications for critical condition monitoring where a non-alarm  
response is desired.  
1 = 30 sec  
7 = 3 min  
#+13 = 10 min  
#+14 = 12 min  
2 = 45 secs 8 = 4 min  
3 = 60 secs 9 = 5 min  
4 = 90 secs #+10 = 6 min  
5 = 2 min  
#+11 = 7 min  
UL: may only be used on non-burglar alarm/ non-fire alarm zones when used  
in fire and/or UL burglar alarm installation  
– 10 –  
 
Program Mode Lockout Options  
0 = standard *98 installer code lockout  
(reentry only by [] + [#] within 50  
secs after power up)  
1 = lockout [] + [#] reentry after *98  
exit (reenter via installer code or  
downloader only)  
2 = not applicable (option doesn’t exist)  
3 = lockout local programming after *98  
exit (reenter by downloader only)  
88  
[0]  
This table summarizes the Program Mode Lockout options:  
Exit  
*88  
Reentry By:  
Command Entry Installer  
Power-up† Downloader  
*99  
*98  
*98  
*98  
n/a  
0
yes  
no  
yes  
yes  
no  
yes  
yes  
yes  
yes  
1
yes  
3
no  
no  
† pressing [] + [#] within 50 seconds of power up  
Event Log Full Report Code  
See box above field *59 for report code  
entries.  
89  
90  
|
[00]  
If an Event Logging selection is made in field 90, a message can be  
sent to the central station receiver when the log is 80% full. If the log  
becomes full, new messages overwrite the oldest messages in the log.  
Event Log Enables  
0 = None  
[3]  
This system can record various events in a history log (FA168CPS =  
100 events; FA148CP = 50 events). At any time, the downloader  
operator can then upload the log and view or print out all or selected  
categories of the log. The downloader operator can also clear the log.  
Event log can also be viewed at an alpha keypad. The display/printout  
at the central station will show the date, time, event, and description of  
the occurrences.  
1 = Alarm/Alarm Restore  
2 = Trouble/Trouble Restore  
4 = Bypass/Bypass Restore  
8 = Open/Close. Example: To select  
“Alarm/Alarm Restore”, and  
“Open/Close”, enter 9 (1 + 8);  
To select all, enter #15.  
Data Entry Example: To select Alarm/Alarm Restore” and  
“Open/Close”, enter 9 (1+ 8); to select all events, enter #15.  
NOTE: System messages are logged when any non-zero entry is made.  
Option Selection  
0 = None  
2 = Sounder Delay (delays sounding by  
15 seconds)  
1 = Bell Supervision Processing†  
4 = AAV  
8 = Exit Delay Restart/Reset ††  
#+12 = AAV and Exit Delay  
Restart/Reset  
91  
[8, 0]  
Options  
SIA-Compliant Controls:  
Call Wait Disable  
Select the desired options by adding the values of each desired option.  
Sounder Delay: If enabled, delays external sounding by 15-seconds.  
IMPORTANT: AAV should not be used when Paging or Alarm Reports  
are sent to a secondary number unless the monitoring zone option is  
used (which pauses calls). Otherwise, the call to the secondary number  
by the communicator after the alarm report will prevent the AAV from  
taking control of the telephone line, and the AAV “Listen in” session  
cannot take place.  
SIA-Compliant Controls:  
Options: Same as for  
FA148CP/FA148CPS.  
Call Waiting Disable:  
0 = call waiting not used  
UL: must use ADEMCO UVCM module; Exit Delay Restart/Reset must be  
disabled  
UL: If Sounder Delay used, entry delay (*35) must be 30 sec. max.  
1 = call waiting disable digits (*70)  
entered in field *40; (when selected,  
the system dials the entry in field *40  
only on alternate dial attempts; this  
allows proper dialing in the event call  
waiting service is later canceled by  
the user).  
SIA Guidelines: Exit Delay should be enabled.  
If bell supervision is selected, you must also cut the red PCB Bell Supervision  
jumper.  
††“Exit Delay Restart/reset” option allows use of the [] key to restart the exit  
delay at any time when the system is armed STAY or INSTANT. This feature  
also enables automatic exit delay reset, which resets exit delay if the entry/exit  
door is re-opened and closed before exit delay time expires after arming AWAY.  
Automatic Exit Delay Reset occurs only once during an armed AWAY period.  
Phone Line Monitor Enable  
92  
[0,0]  
Entry 1:: 0 = disabled, 1-15 = 1 min - 15  
1
2
min  
Entry 1: Sets the length of time a phone line fault must remain after  
detected before the second digit option is activated.  
Entry 2: Selects the desired phone line fault response.  
Option 2 may be used even if a relay unit or Powerline carrier device is  
not connected to the control.  
Programmed Output Device must either be programmed to be  
STOPPED in field 80 or STOPPED by entry of [security code] + [#] + 8  
+ device number. Partition in 80 should be set to “0,” for STOP.  
UL: Field *92 must be enabled for fire alarm installations, UL commercial  
burglar alarm installations and UL residential burglar alarm installations.  
(#+10 = 10 min; #+11 = 11 min; #+12 =  
12 min;  
#+13 = 13 min; #+14 = 14 min; #+15 =  
15 min)  
Entry 2:  
0 = Keypad display when line is faulted  
1 = Keypad display plus keypad trouble  
sound. Each partition turns off its  
own trouble sound. No automatic  
timeout.  
If the control unit is used on a UL commercial burglar alarm system which  
requires 2 methods of remote communication, then the control unit’s DACT  
and the other method of signal transmission must monitor each other against  
communication failure and line fault. The fault must be received and  
annunciated within 200 seconds of its occurrence.  
2 = Same as “1”, plus programmed  
output device STARTS. If either  
partition is armed, external sounder  
activates also. External sounder  
will be turned off by normal bell  
timeout, or by security code plus  
OFF from either partition (it does  
not have to be the one that was  
armed).  
– 11 –  
 
Reports In Armed Period Per  
93  
[1,0]  
Zone (Swinger Suppression)  
Restrict Report Pairs:  
0 = Unlimited Reports  
1 = 1 report pair per zone per armed  
period  
Restrict  
SIA-Compliant Controls:  
Report Pairs Unlimited Reports Enable  
Selection limits the number of alarm/alarm restore message pairs per  
zone sent to the CS in an armed period. Swinger suppression applies  
to burglary zones only.  
2 = 2 report pairs per zone per armed  
period  
SIA Guidelines: Must be set for option 1 or 2  
SIA-Compliant Controls:  
Restrict Report Pairs:  
1 = 1 report pair; 2 = 2 report pairs  
Unlimited Reports Enable:  
0 = restrict reports to the setting in  
entry 1  
1 = unlimited reports for zones listed  
in zone list 7; (use zone list 7 to  
enter those zones that require  
unlimited reporting; these zones  
ignore the setting in entry 1)  
DOWNLOAD INFORMATION ( 94, 95)  
Download Phone No.  
94  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Enter up to 20 digits, 0–9; #+11 for ' ';  
#+12 for '#'; #+13 for a 2-second pause.  
Do not fill unused spaces. If fewer than  
Enter the phone number of the downloading computer.  
UL: downloading may be performed only if a technician is at the site.  
Up/downloading via the Internet has not been evaluated by UL.  
20 digits, exit field by pressing . To  
clear entries from field, press 94 .  
Ring Count For Downloading  
0 = Disable Station Initiated Download;  
1–14 = number of rings (1–9, # +10 =10,  
# +11 =11, # +12 =12, # +13 =13,  
# +14 =14);  
15 = answering machine defeat  
(# +15 =15).  
95  
[15]  
Refer to the chart below and program accordingly.  
phone  
module machine  
answer  
down-  
loading Set field 95 to…  
no  
no  
yes  
yes  
no  
yes  
1-14 (not 0)  
greater than rings set on answer machine  
(e.g., if ans. machine is 4 rings, set this  
field to 5). This allows access to the  
phone module if the answer machine is  
off.  
NOTE: Do not enter 0 if using 4286  
Phone Module.  
yes  
no  
yes  
no  
yes  
no  
yes  
yes  
yes  
no  
no  
yes  
yes  
1-14 (not 0)  
yes  
no  
no  
no  
no  
15 (bypasses answer machine)  
0
0
1-14  
15  
NOTE: If “15” is entered to bypass an answering machine, and a 4286  
Phone Module is included in the system, you should note the following:  
When calling in from an off-premises phone, the user should make the initial  
call, allow 1 or 2 rings only, then hang up, then call again. The phone module  
will now seize the line, and 2 long tones sound, followed by the usual voice  
prompt for the access code. If this procedure is not followed, phone module  
operation will not be possible.  
These are commands, not data fields. See page 3.)  
96, 97 Initialize/Reset Defaults (  
These are commands, not data fields. See page 3.)  
98, 99 Exit Commands (  
PAGER OPTIONS (160- 172)  
The system can send various reports to several pagers (FA168CPS = up to 4; FA148CP = up to 2).  
To program pager reporting, do the following:  
1. Enter the pager phone number(s), preface characters, and pager report options in data fields *160 - *171.  
2. Enable Pager Delay, if desired, in field *172 (delays alarm reporting for ALL pagers).  
3. Make sure appropriate user open/close pager reports are enabled (see Security Codes section in User Guide). Users  
that perform actions in partition 1 will, if enabled, attempt to report to all pagers enabled for open/close reporting in  
partition 1. Users that perform actions in partition 2 will, if enabled, attempt to report to all pagers enabled for open/close  
reporting in partition 2.  
4. If using latchkey pager report, define the latchkey report schedule using Scheduling mode (master code + [#] [6] [4] then  
select event type 03). System must be armed for the Latchkey report to be sent.  
5. If using a function key to manually send a message to a pager, use *57 Function Key Menu mode to define the key  
(function 01).  
6. If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones associated with each  
pager (zone lists 9-12 ).  
FA148CP supports zone lists 9 and 10 only.  
12 –  
 
Pager 1 Phone No.  
Enter up to 20 digits.  
0–9  
160  
161  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If entering fewer than 20 digits, exit by pressing [] + next field number.  
To clear entries, press 160.  
#+11 = ' '  
#+12 = '#'  
#+13 = 2-second pause  
Pager 1 Characters  
Enter the optional prefix characters, up  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Up to 16 optional characters may be sent as a prefix to the 7-digit  
system status code sent to Pager #1 (if used). Phone number in field  
*160 must have been entered. If fewer than 16 characters, exit by  
pressing [] and next field number. To clear entries: press 161.  
The 16 characters may be composed of the following:  
PIN number, Subscriber account number,  
to 16 digits.  
0–9  
#+11 = ' '  
#+12 = '#'  
#+13 = 2-second pause  
(enter # + 11 to send ), # (enter # + 12 to send #), Pause (enter # +  
13 to allow a 2-second pause),†  
special character(s) the user may decide to transmit  
† Some paging systems require pause(s) before the prefix.  
The Pager format for the 7-digit status code is defined as follows: XXX-  
YYYY where:  
XXX  
= 3-digit event code: 911 = Alarm, 811 = Trouble,  
101 = Opening (disarm), 102 = Closing (arm AWAY)  
YYYY = 4-digit user or zone number (depending on type of event).  
The first digit indicates partition (0 = system, 1 = part 1, 2 =  
part 2, 3 = common), followed by the 3-digit user or zone  
number.  
Display Example 1. 9 1 1 – 1 0 0 4 Indicates an alarm (911) caused by  
a fault in zone 4 (0004) in part. 1.  
Display Example 2. 1 0 2 – 2 0 0 5 Indicates the system is reporting a  
closing–system arming (102) by User 5 (0005) in partition 2.  
Pager 1 Report Options  
162  
[0,0,0]  
0 = no reports sent  
P1 P2  
comm  
1 = Opens/closes all users  
For each partition, select from the listed options.  
4 = All alarms and troubles  
5 = All alarms / troubles, and  
opens/closes for all users  
12 = Alarms / troubles for zones  
entered in zone list 9  
13 = Alarms / troubles for zones  
entered in zone list 9, and  
opens/closes for all users  
† For users enabled for paging. Reports to pager only when arming  
(close)/disarming (open) from a keypad using a security code; auto-  
arming/disarming, arming with assigned button, and keyswitch arming  
do not send pager messages.  
Pager 2 Phone No.  
See field 160 for entries.  
163  
164  
165  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If entering fewer than 20 digits, exit by pressing [] + next field number.  
To clear entries, press 163.  
Pager 2 Characters  
See field 161 for entries.  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If fewer than 16 characters, exit by pressing [] and next field number.  
To clear entries, press 164.  
Pager 2 Report Options  
See field *162 for reporting options.  
[0,0,0]  
P1 P2 comm  
Select for each partition (use zone list 10 for options 12 or 13)  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pager 3 Phone No.  
See field 160 for entries.  
166  
167  
If entering fewer than 20 digits, exit by pressing [] + next field number.  
To clear entries, press 166∗  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pager 3 Characters  
See field 161 for entries.  
If fewer than 16 characters, exit by pressing [] and next field number.  
To clear entries, press 167.  
[0,0,0]  
Pager 3 Report Options  
168  
169  
P1 P2 comm  
See field *162 for reporting options.  
Select for each partition (use zone list 11 for options 12 or 13).  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pager 4 Phone No.  
See field 160 for entries.  
If entering fewer than 20 digits, exit by pressing [] + next field number.  
To clear entries, press 169.  
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pager 4 Characters  
See field 161 for entries.  
170  
If fewer than 16 characters, exit by pressing [] and next field number.  
To clear entries, press 170.  
13 –  
 
[0,0,0]  
P2 comm  
Pager 4 Report Options  
171  
172  
P1  
See field *162 for reporting options.  
Select for each partition (use zone list 12 for options 12 or 13).  
Pager Delay Option For Alarms  
0 = none  
1 = 1 minute  
2 = 2 minutes  
3 = 3 minutes  
[3]  
This field determines the delay of alarm reports to the pager. This gives  
the Central Station enough time to verify the alarm report it received  
before the dialer attempts to dial the pager.  
This delay is for ALL pagers in the system.  
MISCELLANEOUS SYSTEM FIELDS (*174-*181)  
Clean Me Reporting Options  
0 = disable  
174  
[0] For ESL smoke detectors  
This is a maintenance feature for ESL 2-wire smoke detectors on Zone  
1. If used, this option limits the number of smoke detectors to a  
maximum of 10, rather than 16. To enable the “clean me” feature, a  
time response setting of “3” (1.2 seconds) must be entered in 56 Zone  
Programming for zone 1.  
1 = Clean Me signal reports  
NOTE: If Clean Me is enabled, you must enter “3” in field 56  
programming for zone 1 response time.  
Device Duration 1, 2  
177  
[0] [0]  
0 = 15 secs 6 = 2-1/2 min #+11 = 7 min  
1
2
1 = 30 secs 7 = 3 min  
2 = 45 secs 8 = 4 min  
3 = 60 secs 9 = 5 min  
4 = 90 secs #+10 = 6 min #+15 = 15 min  
5 = 2 min  
#+12 = 8 min  
#+13 = 10 min  
#+14 = 12 min  
(used in *80 Menu mode-Device Actions 5/6)  
These entries set the duration for output action options 5 (duration 1)  
and 6 (duration 2) programmed in 80 Output Function Programming.  
50/60 Hertz AC Operation  
0 = 60 Hz; 1 = 50 Hz  
181  
[0]  
Select the type of AC power applied to the control (option is used for  
Real-Time Clock synchronization)  
CONFIGURABLE ZONE TYPE OPTIONS (*182-*185)  
(see Configurable Zone Type Worksheet)  
The system allows you to define custom zone types (FA168CPS supports 4 [types 90-93]; FA148CP supports 2 [types 90,  
91]), based on the options described at right.  
All configurable zone types can be programmed via the downloader. Zone types 90-91 can also be programmed from a  
keypad using data fields *182-*185.  
IMPORTANT: Be careful when selecting combinations of options for configurable zone types. Contradictory options can  
cause unpredictable results.  
Configurable Zone Type Options  
Auto Restore (entry 2): Faults on zones set for this option are cleared; restore messages sent upon restoral of faults.  
Vent Zone (entry 2): Zones set for this option are ignored if faulted when arming the system, but are protected if the zone is  
later restored (e.g., an open window can be ignored when arming, but if the window is later closed, it will be protected;  
opening the window again causes an alarm.)  
Bypass Disarmed (entry 4): Zones set for this option can be bypassed only while the system is disarmed.  
Bypass Armed (entry 4): Zones set for this option can be bypassed when the system is armed.  
Dial Delay (entry 6): Alarms on zones set for this option participate in dial delay central station reporting, if system dial delay  
enabled in field *50.  
Fault Delay (entry 6): Faults on zones set for this option are delayed by the time set in field *87. Do not use this option if  
using entry/exit delay for this zone type.  
Faults Display (entry 7): Selects how faults on zones set for this zone type are displayed.  
Power Reset/Verification(entry 7): Selects whether the system resets power (when user enters code + OFF), and whether  
the system performs alarm verification (see description for zone type 16 in Zone Type Definitions section) when a fault  
occurs on these zones.  
Use Entry Delay (entry 8): Selects whether to use the system’s entry delay times.  
Use Exit Delay (entry 8): Selects whether to use the system’s exit delay time.  
Interior Type (entry 8): Zones set for this option are treated same as standard zone type 4 (bypasses when armed STAY,  
faults displayed).  
Alarm Sounds (entry 9): Selects the type of alarms sound for zones set for this zone type.  
Bell Timeout (entry 9): Alarm sounding on zones set for this option remain for the duration set in fields *32 / *33.  
Fire Zone (entry 9): Zones set for this option respond in the same manner as if programmed for zone type 9. Do not set fire  
zones to respond as a “fault” in entries 1-6.  
Trouble Sounds (entry 10): Selects the type of trouble sounds for zones set for this zone type (periodic beeps = once every  
30 seconds; trouble beeps = rapid beeping).  
Chime Enable (entry 10): Zones set for this option cause a chime when Chime mode is on.  
14 –  
 
Configurable Zone Type 90  
(0-9, #+10=10, #+11=11, #+12=12,  
#+13=13, #+14=14, #+15=15).  
182  
183  
1
2
3
4
5
6
7
8
9
10  
Enter the appropriate value for each entry, 1-10, based on the charts  
provided in the Configurable Zone Type Worksheet section. Each entry  
is the sum of the values of its selected options  
To calculate the value for each entry, add the values of the selected  
options in each of the entry’s columns shown in the respective chart  
(one option per column). For example, to program entry 2 for “alarm  
response to short,” “auto restore on,” but not a “vent zone,” enter 5 (“1”  
for alarm short + “4” for auto restore-yes + “0” for vent zone-no).  
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.  
Enter the desired 3-digit Contact ID® report codes for alarms and  
troubles occurring on zones assigned to this zone type. Enter the  
codes sequentially (all 6 digits). When entering digits, [#] moves cursor  
back, [] moves forward.  
Zone Type 90 Report Codes  
90 ALARM ID: XXX  
TROUBLE ID: XXX  
NOTE: Zone alarm report codes and trouble report code (60) and  
relevant restore codes must be enabled in order to report configurable  
zone type codes.  
Press [] when done to continue.  
Important Notice on Report Codes: To avoid confusion at the central  
station, it is recommended that existing Contact ID® codes be used  
with configurable zone types whenever possible. Check with the central  
station for a complete list of Contact ID® report codes. If none of the  
codes are suitable, choose a code in the reserved range of 750-789  
and make sure to define the code with your central station.  
Configurable Zone Type 91  
(0-9, #+10=10, #+11=11, #+12=12,  
#+13=13, #+14=14, #+15=15)  
184  
1
2
3
4
5
6
7
8
9
10  
See 182 for entries.  
UL: Do not configure zones as a fire alarm or UL burglar alarm zone.  
See 183 for entries.  
Zone Type 91 Report Codes  
91 ALARM ID: XXX  
TROUBLE ID: XXX  
185  
189  
AUI Device Enables  
(for Touch Screen Style Keypads)  
FA168CPS: Enter each touch screen  
keypad’s home partition  
0 = disable  
1 = partition 1  
2 = partition 2  
3 = partition 3 (common)  
[1, 1, 0, 0]  
AUI 1  
AUI 2 AUI 3 AUI 4  
System supports touch screen style keypads (e.g., Symphony  
Advanced User Interface, and 6270 Touch Screen Keypad;  
FA168CPS = up to 4; FA148CP = up to 2).  
NOTE: Use of touch screen style keypads does not affect the number  
of standard keypads supported.  
AUI Compatibility Note: To ensure proper AUI device operation, use  
AUI devices with the following rev levels: FA700KP series use  
version 1.0.9 or higher; 8132/8142 (Symphony) series use version  
1.1.175 or higher.  
FA148CP:  
0 = disable  
1 = enable  
Touch Screen (AUI) device 1: Must set device address to 1  
Touch Screen (AUI) device 2: Must set device address to 2  
Touch Screen (AUI) device 3: Must set device address to 5  
Touch Screen (AUI) device 4: Must set device address to 6  
15 –  
 
KEYPAD OPTIONS *190-*199  
To enable keypads:  
1. Set desired address at keypad (refer to keypad’s instructions for setting the address).  
2. Use data fields *190-*196 to enable keypad addresses, assign a partition, enable sound options in field.  
3. Use fields *197, *198, and *199 to turn on partition number display, exit time interval display, and select fail display mode.  
4. Set keypad-related data fields as appropriate: *21 Quick Arm Enable, *23 Forced Bypass, *84 Auto STAY Arm  
NOTES: 1. Options for keypad 1, address 16, are set by the factory and cannot be changed.  
2. Each keypad must be assigned a unique address. Keypads programmed with the same address will give  
unpredictable results.  
Keypad 2 Device Address 17  
190  
[0] [0]  
Partition/ Enable:  
Partition/  
Enable  
Sound  
FA168CPS: Enter partition where:  
0 = keypad disabled  
Partion/Enable: For FA168CPS, enter the partition in which the  
keypad is located; for FA148CP, enter 1 to enable, or 0 to disable the  
keypad.  
1-3 = part. no. (3 = common)  
FA148CP:  
0 = disable  
1 = enable  
Sound: 0 = no suppression  
1 = suppress arm/disarm and Entry/Exit  
beeps  
Sound: Enter the desired sound option for this keypad.  
2 = Suppress chime beeps only  
3 = suppress arm/disarm, Entry/Exit,  
and chime beeps  
Keypad 3 Device Address 18  
See field 190 for entries.  
191  
192  
193  
194  
195  
196  
197  
[0] [0]  
Part/Enable Sound  
Keypad 4 Device Address 19  
See field 190 for entries.  
[0] [0]  
Part/Enable Sound  
Keypad 5 Device Address 20  
See field 190 for entries.  
[0] [0]  
Part/Enable Sound  
Keypad 6 Device Address 21  
See field 190 for entries.  
[0] [0]  
Part/Enable Sound  
Keypad 7 Device Address 22  
See field 190 for entries.  
[0] [0]  
Part/Enable Sound  
Keypad 8 Device Address 23  
See field 190 for entries.  
[0] [0]  
Part/Enable Sound  
Exit Time Display Interval  
0 = no display  
[0]  
If enabled, keypads display the exit time remaining after arming the  
system, updated at the interval selected (i.e. if the exit delay is 30  
seconds and “2” is selected in this field, the keypad display refreshes  
every 2 seconds, displaying 30, 28, 26, 24, etc.).  
1-5 = seconds between display refresh  
An interval greater than “1” may be necessary for some older keypads  
to allow users time to enter key presses between display updates.  
NOTE: If enabled and using only 2-digit fixed-word keypads (e.g.,  
FA245RF), do not set exit delay time greater than 96 seconds. Using a  
longer delay time may cause end-user confusion because 2-digit  
display keypads cannot display times greater than “99.” If longer exit  
time is required by the installation, it is recommended that the Exit  
Time Display option be disabled (“0”).  
TOUCH SCREEN DEVICE NOTE: If using more than one touch screen  
device (e.g., FA700KP, Symphony) with the system, leave field *197  
Exit Time Display Interval set to the default value “0.” The FA700KP  
automatically displays remaining exit time in one-second increments.  
[0]  
Display Partition Number  
0 = no  
1 = yes (partition no. displayed)  
198  
199  
(FA168CPS; for Alpha Display Keypads)  
If selected, the partition number is displayed in the upper-left corner of  
the display. This is useful when using the GOTO partition function.  
ECP Fail Display  
0 = 3-digit display  
“1” + device address)  
1 = 2-digit fixed-display as “91  
[0]  
Select “0” if using Alpha keypads and/or 3-digit Fixed-Word Display  
keypads. ECP faults will display “1” plus the device address (00-30) of  
device causing the fault (e.g., faults on device 07 display as “107”).  
Select “1” if using 2-digit Fixed-Word Display keypads (e.g., certain  
6128 series keypads). If selected, ECP faults for all devices will display  
as “91” on 2-digit displays, and “191” on 3-digit or Alpha keypads.  
16 –  
 
CONFIGURABLE ZONE TYPES WORKSHEETS  
Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data  
fields*182-*185. Configurable zone types 92 and 93 (FA168CPS only) can only be programmed using the  
downloader software.  
Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and  
field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the  
tables below. Use fields *183 and *185 to program Contact ID report codes for these zone types.  
Entries for Fields *182 and *184  
ENTRY 1 (See note 5 for RF zones) ENTRY 2 (See note 5 for RF zones)  
Entry Zone Type 90  
(field *182)  
Zone Type 91  
(field *184)  
Response when system disarmed and zone is:  
Auto  
Restore  
Vent Zone  
Intact EOL  
Open  
RF zone N/A  
Shorted  
RF zn off-normal  
1
2
3
4
5
RF zone normal  
0 = normal  
1 = alarm  
2 = trouble  
3 = fault  
0 = normal  
4 = alarm  
8 = trouble  
12 = fault  
0 = normal  
1 = alarm  
2 = trouble  
3 = fault  
0 = no  
4 = yes  
0 = no  
8 = yes  
Entry 1 = EOL + Open  
Entry 2 = Short + auto restore + vent zone  
6
ENTRY 3 (See note 5 for RF zones) ENTRY 4 (See note 5 for RF zones)  
7
8
9
10  
Response when armed STAY and zone is:  
Byp. when  
disarmed  
Byp. when  
armed  
Intact EOL  
RF zone normal  
Open  
RF zone N/A  
Shorted  
RF zn off-normal  
0 = normal  
1 = alarm  
2 = trouble  
3 = fault  
0 = normal  
4 = alarm  
8 = trouble  
12 = fault  
0 = normal  
1 = alarm  
2 = trouble  
3 = fault  
0 = no  
4 = yes  
0 = no  
8 = yes  
To calculate the value for each entry:  
Simply add the values of the selected options  
in each of the entry’s columns (one option per  
column). For example, to program Entry 2 for  
“alarm response to short,” “auto restore on,”  
but not a “vent zone,” enter 5 (“1” for alarm  
short + “4” for auto restore yes + “0” for vent  
zone no).  
Entry 3 = EOL + Open  
ENTRY 5 (See note 5 for RF zones) ENTRY 6 (See note 5 for RF zones)  
Response when armed AWAY and zone is: Dial Delay  
Entry 4 = Short + byp. disarmed + byp. armed  
Fault Delay  
(see field *50) (see field *87)  
Intact EOL  
Open  
RF zone N/A  
Shorted  
RF zn off-normal  
RF zone normal  
0 = normal  
1 = alarm  
2 = trouble  
3 = fault  
0 = normal  
4 = alarm  
8 = trouble  
12 = fault  
0 = normal  
1 = alarm  
2 = trouble  
3 = fault  
0 = no  
4 = use delay  
0 = no  
8 = use delay  
see note 1  
Entry 5 = EOL + Open  
Entry 6 = Short + dial delay + fault delay  
INTACT  
EOL  
OPEN  
SHORTED  
ENTRY 7  
ENTRY 8  
ZONE-003-V0  
Zone Conditions Represented  
in Entries 1-6  
Display Faults  
Power Reset/  
Verification  
Use Entry  
Delay 1/2  
Use Exit  
Delay  
Respond as  
Interior Type  
0 = show alarms 0 = no  
0 = no  
1 = delay 1  
2 = delay 2  
0 = no  
4 = use exit  
delay  
0 = no  
8 = yes  
NOTES:  
when armed 4 = power reset  
1. Do not use the “fault delay” option with a  
configurable zone type if it is set for an  
entry or exit delay, otherwise  
& disarmed  
1 = don’t show  
alarms when  
after fault  
(by code + OFF)  
12 = verification  
(see zone  
see note 2  
unpredictable results may occur.  
armed (show  
alarms, trbles,  
faults when  
2. To create an interior type zone, select  
“respond as interior zone type” (entry 8,  
interior type = yes), and set zone  
response to “fault” in entries 3-4 to ensure  
fault displays; do not set as “normal,”  
“alarm,” or “trouble.”  
3. Do not set fire zones to respond as a  
“fault” (entries 1-6), otherwise faults will  
not display unless the [] key is pressed.  
4. 4219/4229 modules must use EOLRs or  
unpredictable results may occur.  
5. RF Zones: The “open” option in entries 1,  
3, and 5 is not applicable for RF zones.  
Use the “intact EOL” option for normal RF  
zone conditions and “shorted” for off-  
normal RF zone conditions.  
type 16)  
disarmed)  
3 = never show  
any alarms,  
trbles, faults  
Entry 7 = fault display + power  
reset/verification  
Entry 8 = entry delay 1/entry delay 2 + exit delay +  
interior zone type  
ENTRY 9  
ENTRY 10  
Alarm Sounds  
Use Bell  
Timeout  
Respond as  
Fire Zone  
0 = no  
Trouble  
Sounds  
0 = none  
1 = periodic  
beep  
2 = trouble  
beeps  
Chime when  
Chime Mode On  
0 = no  
0 = none  
1 = steady  
keypad  
0 = no  
4 = yes  
8 = yes  
4 = yes  
2 = steady bell see fields *32,  
and keypad *33  
3 = pulsing bell  
see zone type  
09; see note 4  
6. a. Zone-Doubling/Double-Balanced: A  
short on either zone of a zone-doubled  
pair or on a double-balanced zone  
causes a tamper condition.  
and keypad  
Entry 9 = alarm sounds + bell timeout + fire zone  
Entry 10 = trouble sounds + chime  
b. For double-balanced zones, this entry  
must be “0.”  
c. For zone-doubled zones, both zones  
of the doubled pair must be assigned  
the same response to a short.  
17 –  
 
56 ZONE PROGRAMMING MENU MODE  
(press *56 while in Program mode) The Zone Programming Worksheet is on page 36.  
Zones and Partitions  
Each protection zone needs to be programmed with various attributes using *56 Zone Programming mode or 58 Expert  
Programming Mode. Using this mode, enter the zone number to be programmed and make appropriate entries at the  
prompts. Finally, Confirm the serial number of wireless transmitter zones.  
The FA168CPS system can control two independent areas of protection (known as partitions) for use by independent users, if  
desired, by simply assigning zones to one or the other partition during zone programming. The FA168CPS, by default,  
automatically distributes users between the two partitions. The master user can change the user number distributions.  
Zones can also be assigned to a common partition, which is an area shared by users of both partitions (such as a lobby in a  
building). This allows either partition to arm, while leaving the common partition disarmed for access into the other partition.  
The following describes the functioning of the FA168CPS common partition:  
• The common zone sounds and reports alarms only when both partitions are armed. If only one partition is armed, the  
system ignores faults on the common zone.  
• Either partition may arm its system if the common zone is faulted, but once armed, the other partition will not be able to arm  
unless the common zone is first bypassed or the fault is corrected.  
• Faults on the common zone are displayed on common zone keypads, and will also appear on another partition’s keypad  
when that partition is armed.  
• Either partition can clear and restore the common zone after an alarm.  
56 Menu Mode  
PROMPT  
VALID ENTRIES  
EXPLANATION  
This display appears upon entry into this mode.  
The default is 0 (No).  
Confirm?  
0 = no  
1 = yes  
SET TO CONFIRM?  
0 = NO 1 = YES 0  
If 1 (Yes) is entered, you will be prompted to confirm each  
transmitter after entering the serial and loop numbers (at the  
“XMIT TO CONFIRM” prompt later).  
[] to continue  
Enter the zone number that you wish to program. Zone 10 has  
been entered in the example display at left.  
Enter a report code for zone 91 to enable addressable device  
reporting.  
Enter a report code for zone 92 to enable duress reporting.  
95, 96, 99 are emergency (panic) key zones.  
Zone Number  
FA168CPS:  
wired 01-08 (and 09-48†);  
wireless 09-48; RF button  
zones 49-64  
Enter Zn Num.  
(00 = Quit) 10  
FA148CP:  
wired 01-06 (and 07-22†);  
wireless 09-34; RF button  
zones 49-56  
† if zone expanders are used.  
Both Controls:  
91 = addr. device report enable  
92 = duress report enable  
95, 96, 99 =emerg. zones  
[] to continue  
00 to quit  
“IN: L” appears for wireless zones and indicates input type and  
loop.  
“IN: AD” appears for hardwire expansion zones (AW) and  
indicates the module’s address (AD), which is based on the  
zone number.  
Summary Screen  
[] to continue  
Zn ZT P RC In:  
10 00 1 10 RF:  
L
1
“HW: RT” appears for hardwire zones and indicates  
configuration (EOL, NO, NC, zone doubling, double-balanced)  
and response time selection.  
Each zone must be assigned to a zone type, which defines the  
way in which the system responds to faults in that zone. Enter the  
Zone Type code from the list below:  
Zone Type (ZT)  
See table at right.  
10 Zone Type  
Perimeter  
03  
Note: If 00 is entered, Delete Zone ? will be displayed.  
00 = Not used  
07 = 24-Hr Audible  
08 = 24-Hr Aux  
09 = Fire  
20 = Arm–STAY*  
21 = Arm–AWAY*  
22 = Disarm*  
01 = Entry/exit #1  
02 = Entry/exit #2  
03 = Perimeter  
23 = No Alarm Resp  
10 = Interior w/Delay  
04 = Interior Follower 12 = Monitor Zone  
24 = Silent Burglary  
05 = Day/Night  
06 = 24-Hr Silent  
14 = Carbon Monoxide 77 = Keyswitch  
16 = Fire w/Verify  
81 = AAV Mon. Zone  
*5800 button-type transmitters only  
Enter the Partition number for this zone. Partition 1 is shown  
entered.  
Partition No. (P)  
(FA168CPS)  
1-3 = partition  
(3 = common)  
[] to continue  
10 Partition  
1
18 –  
 
Enter the report code for this zone, which consists of 2  
hexadecimal digits, each in turn consisting of 2 numerical digits.  
For example, for a report code of “10,” enter 01 and 00.  
For Contact ID®, entering any non-zero entry as the first digit  
enables the report code for this zone.  
Report Code (RC)  
10 Report Code  
First Digit: 1-9, 10 for 0, 11 for  
B, 12 for C, 13 for D, 14 for E,  
15 for F  
1st 01 2nd 00 10  
00 to disable  
Second Digit: same as above  
[] to continue  
This prompt appears only for zone numbers 02-08.  
Zone 1 is automatically set for EOL operation.  
Hardwire Type  
0 = EOL  
1 = NC  
02 HARDWIRE TYPE  
EOL  
0
† FA168CPS  
2 = NO  
3 = zone doubling (ZD) †;  
4 = double-balanced (DB)†  
[] to continue  
Appears only for hardwire zones 01-08 (zone 02 is the display  
shown).  
Option 3: used for “clean me” option on zone 1 (see field 174).  
NOTE: If zone doubling is being used, the response time  
selected for zones 02-08 automatically applies to each zone’s  
associated doubled zone.  
Response Time (RT)  
0 = 10mSec;  
1 = 350mSec  
2 = 700mSec  
3 = 1.2 seconds  
[] to continue  
02 Response Time  
1
This prompt is skipped for zones 2-8, or 2-16 if zone-doubling  
was enabled at “Hardwire Type” prompt.  
All of the RF transmitters have one or more unique factory-  
assigned input (loop) ID codes. Each of the inputs requires its  
own programming zone (e.g., a 5804's four inputs require four  
programming zones).  
Input Device type (In)  
2 = AW (Aux wired zone)  
3 = RF (supervised RF  
transmitter  
4 = UR (unsupervised RF  
transmitter)  
5 = Button type RF  
transmitter  
(unsupervised).  
[] to continue  
10 INPUT TYPE  
RF TRANS  
3
RF Transmitters can be enrolled as one of the following types:  
Type  
Description  
Sends periodic check-in signals, as well as  
fault, restore, and low-battery signals. The  
trans. must stay within receiver's range.  
Sends all the signals that the “RF” type  
does, but the control does not supervise  
the check-in signals. The transmitter may  
therefore be carried off-premises.  
RF  
(Supervised RF)  
UR  
(Unsupervised RF)  
Sends only fault signals. It will not send a  
low-battery signal until it is activated. The  
transmitter may be carried off-premises.  
BR  
(Unsupervised  
Button RF)  
NOTE:  
For the built-in hardwired zones, the Input Device type is  
automatically displayed as HW and cannot be edited.  
To change the input type of a previously programmed wireless  
device (type RF, UR, BR) to a wired zone (type AW), you must  
first delete transmitter’s serial number (see To Delete A Serial  
Number prompt)  
Input Serial number and  
Loop Number  
[] to continue  
Used only when enrolling  
wireless transmitters.  
Enroll the transmitter’s serial number and loop number as  
follows:  
1. a. Transmit two open/close sequences (for button-type trans,  
press and release the button twice, waiting about 4 secs  
before pressing the button the second time).  
OR  
10 INPUT S/N:  
A022-4064  
L
1
b. Manually enter the 7-digit serial number printed on the label  
of the transmitter. Press the [] key to move to the “L”  
position, then enter the loop number.  
Use the [A] (Advance) and [B] (Back) keys to move the  
cursor forward and back within the screen. Pressing the [C]  
(Copy) key will insert the previously enrolled serial number,  
if desired (used when programming a transmitter with  
several input loops).  
To delete an existing serial number, enter 0 in the loop  
number field. The serial number will change to 0's. If 0  
was entered in error, simply re-enter the loop number or  
press [#], and the serial number will return to the display.  
2. Press [] to continue. The system now checks for a duplicate  
serial/loop number.  
If no duplicate is found, the display shows the serial number  
and loop number.  
3. Press [] to continue to confirmation screen.  
19 –  
 
NOTE: If the [C] key is used to copy the previously enrolled  
serial number, the cursor will move to the Loop column (L) with  
the previous serial number displayed, and display a highlighted  
question mark for the loop number.  
Loop Number Change  
[] to continue  
10 INPUT S/N  
A022-4064  
L
?
Enter the loop number and press []. The system will now  
check for a duplicate serial/loop number combination.  
This prompt will only appear if you answered “Yes” at the first  
prompt in this section.  
The system will enter a confirmation mode so that the operation  
of the actual programmed input can be confirmed.  
Confirmation Option  
[] to continue  
XMIT TO CONFIRM  
PRESS TO SKIP  
Activate the loop input or button that corresponds to this zone.  
If the serial number transmitted does not match the serial  
number entered, a display similar to the one shown appears. If  
the loop number does not match, it will also be displayed.  
If so, activate the loop input or button on the transmitter once  
again. If a match is not obtained (i.e., summary display does not  
appear), press the [#] key twice and then enter (or transmit) the  
correct serial number.  
If Serial or Loop  
Numbers do not match  
after activating the  
transmitter  
Entd A022-4063 1  
Rcvd A022-4064  
1
[] to continue  
To delete an existing serial number, enter 0 in the loop number  
field. The serial number will change to 0's.  
If 0 was entered in error, simply re-enter the loop number or  
press [#], and the serial number will return to the display.  
To Delete a Serial No.  
0 = delete serial number  
# = undo deletion  
10 INPUT S/N:  
A000-0000  
L
0
[] to continue  
If the serial number transmitted matches the serial  
number entered, the keypad will beep 3 times and a  
summary display will appear, showing that zone's  
programming. Note that an “s” indicates that a  
transmitter’s serial number has been enrolled.  
Summary Screen  
[] to continue  
Zn ZT RC In: L  
10 03 10 RF: 1s  
Press [] to accept the zone information and continue.  
If you want to program descriptors for zones now, enter 1 (Yes)  
and refer to the 82 Descriptor Programming section for  
available descriptors.  
Alpha Descriptors  
0 = no  
1 = yes  
PROGRAM ALPHA?  
0 = NO 1 = YES  
0
[] to continue  
If 0 (No) was entered above, the system will return you to the  
ENTER ZN NUM. prompt for the next zone.  
When all zones have been programmed, enter 00 to quit  
Next Zone Number  
[] to continue;  
00 = quit  
ENTER ZN NUM.  
(00 = QUIT) 11  
Completing Zone Programming  
When you have finished programming all zones, test each zone using the system’s TEST mode.  
Do not use the Transmitter ID Sniffer Mode for checking wireless transmitting devices, as it will only check for  
transmission of one zone on a particular transmitter, NOT the zones assigned to each additional loop.  
58 EXPERT ZONE PROGRAM MODE  
(press 58 while in Data Programming mode)  
This method is designed for use by installers with previous experience in programming First Alert Professional control panels.  
This mode is also used to program wireless keys using pre-defined templates.  
Select whether you want confirmation of wireless device  
enrollment. (See “XMIT TO CONFIRM” prompt later in this  
section.) We recommend that you confirm the programming  
of every transmitter.  
Confirm?  
0 = no; 1 = yes; [] to  
continue  
SET TO CONFIRM?  
0 = NO 1 = YES 0  
If 1 (Yes) is entered, you will be prompted to confirm each  
transmitter after entering the serial and loop numbers (at the  
“XMIT TO CONFIRM” prompt later).  
A summary screen appears, showing zone 1’s currently  
programmed values.  
Summary Screen  
01-64 = zone number;  
[] to continue;  
Zn ZT P RC HW: RT  
01 09 1 10 EL  
1
Enter the zone number being programmed, then press [], which  
displays a summary screen for that zone and the cursor moves  
to the Zone Type location. The cursor then automatically moves  
to the next locations after each entry is made.  
If programming a wireless key, press the [D] key then skip to  
the Wireless Key Programming Templates section following this  
section. When [D] is pressed, you can choose from a series of  
preset templates for easy programming of wireless key zones.  
00 = quit  
[D] to go to prompts for  
wireless key programming  
templates  
When all zones have been programmed, press 00 at this prompt  
to quit this menu mode.  
20 –  
 
A summary screen with the selected zone’s current  
programming appears.  
Zone Programming  
ZT = see Zone Type chart  
shown in *56 Menu  
Mode “Zone Type”  
prompt  
P = partition 1, 2, 3  
(common);  
RC = 1 (send CID report); 0  
(no report)  
IN = input type;  
Zn ZT P RC IN: L  
10 00 1 10 RF 1  
Begin programming zone information as follows:  
Enter Zone Type (ZT), Partition (P), Report Code (RC; 0-9  
only; use *56 mode to enter hex codes), and Input Device  
Type (IN)* sequentially, but not the Loop No. (L).  
Use the [A] (Advance) and [B] (Back) keys on the keypad to  
move the cursor within the screen.  
Use the [C] key to copy the previous zone’s attributes.  
Press [] to save the programming and continue to the serial  
number/loop number prompt. If needed, you can press the [#]  
key to back up without saving.  
L = loop number  
[] to continue  
* If HW (hardwired) or AW (Auxiliary) is entered for Input Device  
Type, the next screen will be similar to the prompt shown, except  
that HW or AW will be displayed under “IN”.  
If RF, BR, or UR is entered, a prompt for Serial and Loop  
number will be displayed, as described in 56 Menu mode  
section.  
When done, the display returns to the initial summary screen  
prompt to let you program the next zone.  
To exit this mode, enter 00 at the Summary Screen prompt.  
WIRELESS KEY PROGRAMMING TEMPLATES  
(press the [D] key from *58 Menu mode Summary Screen)  
This procedure programs the wireless keys, but a key is not active for arming/disarming until it is assigned to a user  
number (see System Operation section, Assigning Attributes Command in the User Guide).  
Enter Template number 1–6 (see chart on next page).  
See the defaults provided for each template in the chart that  
follows these procedures.  
Template Number  
1–3 = 5804 templates; 4–6  
= 5804BD templates  
TEMPLATE ?  
1–6  
1
Select from templates. Press [] to display template (1  
shown selected).  
NOTE: If necessary, press [#] to back up and re-enter  
template number.  
Press [#] if you want to return to *58 Menu mode summary  
screen.  
When [] is pressed, the selected template will be displayed.  
Top line of display represents loop numbers; bottom line  
represents zone type assigned for each loop.  
Press [] to accept template.  
Template Display  
L
T
01 02 03 04  
23 22 21 23  
Enter the partition in which the key is to be active, then press  
[] to continue.  
Partition  
FA168CPS. 1 = partition 1;  
2 = partition 2  
PARTITION  
1
The system will search for the highest available consecutive  
4-zone group (the four zones in the case of the 5804 and  
5804BD), and display the lowest zone number of the group.  
If you want to start at a different zone, enter the zone desired,  
and press []. If that zone number is displayed, the system  
has the required number of consecutive zones available,  
beginning with the zone you entered. If not, the system will  
again display a suggested zone that can be used.  
Start Zone Number  
ENTER START ZONE  
00 = QUIT  
36  
If the required number of consecutive zones is not available  
at all, the system will display “00”.  
To quit this mode and return to *58 Menu mode, enter 00 at  
this prompt.  
Press [] to accept.  
Manually enter the serial number printed on the label for the  
wireless key or press and release the button to transmit its  
serial number.  
Serial Number  
INPUT S/N  
L
AXXX-XXXX  
Press [] to accept the serial number. The system will check  
for a duplicate.  
If necessary, press the [#] key to back up without saving, and  
re-enter the serial number.  
Use the [A] key to move forward within the screen, and the  
[B] key to move backward.  
21 –  
 
If “Yes” was entered at the SET TO CONFIRM? prompt  
previously (see first prompt following entry into the 58  
Expert Programming Mode), the display on the left will  
appear. Confirm serial and loop numbers by activating the  
wireless key.  
Confirm  
[] to continue  
XMIT TO CONFIRM  
PRESS TO SKIP  
IMPORTANT:  
When confirmed, the key is not active for arming/disarming until  
it is assigned to a user number (using the assigning attributes  
command, attribute “4”). See System Operation section for  
procedure.  
If the serial number transmitted does not match the serial  
number entered, a display similar to the one shown will appear.  
If the loop number does not match, it will also be displayed.  
If so, activate the button on the wireless key once again. If a  
match is not obtained (i.e., summary display does not appear),  
press the [#] key and then enter the correct serial number.  
Not Confirmed  
[] to continue  
Entd A022-4063  
Rcvd A022-4064  
If the serial number transmitted matches the serial number  
entered, the keypad will beep 3 times and will return you to the  
Zone Number prompt to enter the starting zone for the next  
wireless key.  
Or you can return to *58 Menu mode by pressing 00 at the Zone  
Number prompt.  
NOTE: Following the successful enrollment of each wireless  
device, remove ONE of the serial number labels from the device  
and affix it in the appropriate column on the ZONE  
PROGRAMMING worksheet of the Programming Form; then  
enter the other information (zone number, zone type, loop  
number, etc.) relevant to that device.  
Wireless Key Predefined Default Templates  
LOOP 3  
GREEN/YELLOW  
LED  
LOOP 2  
YOU MUST  
PROGRAM  
THIS BUTTON  
LOOP 4  
OFF  
LOOP 2  
LOOP 1  
ON  
Note:  
These transmitters  
are not intended for  
use in UL  
RED/YELLOW  
LED  
LOOP 4  
(YOU MUST  
PROGRAM  
THIS BUTTON)  
LOOP 3  
installations.  
LOOP 1  
• •  
• •  
ENROLL AS "BR"  
ENROLL AS "BR"  
5804BD-007-V0  
5804-001-V1  
5804BD 2-Way Wireless Key  
Transmitter  
5804 Wireless Key Transmitter  
For 5804  
For 5804BD  
TEMPLATE 1  
Loop Function  
Zone Type  
TEMPLATE 4  
Loop  
1
2
3
Function  
No Response  
No Response  
Arm Away  
Disarm  
Function  
No Response  
Arm Stay  
Arm Away  
Disarm  
Function  
24-hour audible  
Arm Stay  
Zone Type  
1
2
No Response  
Disarm  
23  
22  
21  
23  
23  
23  
21  
22  
3
4
Arm Away  
No Response  
Function  
No Response  
Disarm  
4
TEMPLATE 2  
TEMPLATE 3  
Loop  
1
2
Zone Type  
TEMPLATE 5  
TEMPLATE 6  
Loop  
1
2
3
Zone Type  
23  
22  
21  
20  
23  
20  
21  
22  
3
4
Arm Away  
Arm Stay  
Function  
24-hour audible  
Disarm  
4
Loop  
Zone Type  
Loop  
Zone Type  
1
2
3
4
7
1
2
3
4
7
22  
21  
20  
20  
21  
22  
Arm Away  
Arm Stay  
Arm Away  
Disarm  
22 –  
 
57 FUNCTION KEY PROGRAMMING MENU MODE  
(press 57 while in Data Programming mode).  
The system provides the ability to program each of the four keypad function keys to perform one of 12 system operations. The  
end user can then activate the function by simply pressing and holding the programmed key for 2 seconds. Typical functions  
(listed below) include single-button arming, turning lights on/off, or single-button paging.  
To assign emergency key functions (function key option “00”), first program the respective emergency zone number (95 for  
“A” key, 96 for “C” key, 99 for “B” key) with the desired zone type using 56 (or 58) Zone Programming mode, then use 57  
Function Key menu mode to assign the desired key.  
To use a function key to activate a relay action (57 Menu mode key function 07), use 79 Menu mode to map the output, and  
use 80 Menu mode to define the output’s action; select system operation type “66.”  
To use a function key for a user macro, use 57 menu mode to activate the desired key, then define the actual macro  
functions using the user code + [#] + [6] [6] command.  
Press the desired function key (A-D) you want to program.  
NOTE: A key programmed as a function key is no longer  
available to be used as an end-user macro key or panic key.  
Function Key  
Press the desired function  
key, A-D.  
Press Key to Pgm  
0 = Quit  
0
[] to continue  
OFF  
AWAY  
TEST  
CODE  
STAY  
A
B
C
D
1
4
7
2
5
8
0
3
6
9
#
0 = Exit this mode  
BYPASS  
CHECK  
MAX  
INSTANT  
READY  
*
Enter the partition in which the function key is active.  
Partition Number  
Partition  
(FA168CPS)  
1 = partition 1  
1
2 = partition 2  
3 = common partition  
[] to continue  
Enter the desired function for this key, 00 to 12, from the options  
listed. (00 selected for example display shown at left). Press []  
to returns to key number prompt with the next function key letter  
Define Key Function  
00-12 = see list at right  
[] to continue; returns to  
key number prompt with the  
next function key letter  
displayed  
Key "A" Func  
Zone 95  
00  
displayed.  
00  
=
For the Function key selected, the functions are predefined as  
follows:  
If A selected = Zone 95 (emergency key, same as [1] [] pair)  
If B selected = Zone 99 (emergency key, same as [] [#] pair)  
If C selected = Zone 96 (emergency key, same as [3] [#] pair)  
If D selected = Single-button paging  
01 = Single-button paging (sends a 999-9999 message to pager)  
02 = Display time  
03 = Arm AWAY (reports as User 00 if closing reports are enabled)  
04 = Arm STAY (reports as User 00 if closing reports are enabled)  
05 = Arm NIGHT-STAY (reports as User 00 if closing reports enabled)  
†††  
06 = Step Arming (arms STAY, then NIGHT-STAY  
, then AWAY)  
07 = Output Device Command (for device programmed as system  
operation type 66–function key in *80 Menu Mode)  
08 = Communication Test (sends Contact ID code 601)  
09 = Macro Key 1 (define macro by user code + [#] [6] [6] command)  
10 = Macro Key 2 (define macro by user code + [#] [6] [6] command)  
††  
11 = Macro Key 3 (define macro by user code + [#] [6] [6] command)  
††  
12 = Macro Key 4 (define macro by user code + [#] [6] [6] command)  
† System defaults to these function key settings.  
†† Macros 11-12 apply to FA168CPS only.  
††† If Night-Stay zones are listed in zone list 5  
23 –  
 
OUTPUT DEVICE PROGRAMMING GENERAL INFORMATION (*79/*80 Menu Mode)  
Output Devices:  
The FA168CPS system supports up to 16 relays and/or Powerline Carrier devices (X-10 devices)  
plus 2 built-in trigger outputs in any combination. These 18 “outputs” are assigned to system-wide  
output numbers (01-18). Use *79 Menu Mode to assign output numbers and map them to device  
addresses.  
The FA148CP supports 8 relays and 2 built-in trigger outputs (total 10 outputs).  
Output Functions:  
The system also provides installer-defined output functions, which can be assigned to any of the  
physical outputs. Therefore, the action of any one of the outputs can be based on as many of these  
defined functions as desired. This lets a single relay or X-10 device perform many functions.  
The control supports: FA168CPS = up to 48 defined functions; FA148CP = up to 24 functions  
Use *80 Menu Mode to define output functions.  
WARNING: Relays and output devices are not recommended for life safety applications.  
NOTE: When navigating the *79 and *80 menus: The [ ] key is used to accept an entry and advance to the next prompt.  
The [#] key is used to revert back to the last question to check or change an entry. Press [ ] to go forward again.  
Programming Output Devices  
1. Use *79 Menu Mode to assign module and output numbers and map them to device addresses.  
NOTE: You must map output devices using *79 Menu Mode before you can use *80 menu Mode.  
2. Use *80 Menu Mode to create output definitions, which control the output devices, if desired.  
3. Use *81 Zone List Menu mode to define zone lists for use with output devices if the device action is based on more than  
one zone.  
To program a device for manual activation (user code + [#] [7] / [#] [8] + 2-digit device number) or for scheduled automatic  
activation, simply map the device using *79 Menu mode.  
To program a device to automatically activate upon a system event (or function key), use *79 Menu mode to map the device,  
then use *80 Menu mode to define the automated device action.  
79 RELAY/POWERLINE CARRRIER DEVICE (X-10) PROGRAMMING MENU MODE  
(press 79 while in Programming mode) The *79 Device Mapping Worksheet is on page Error! Bookmark not defined..  
Use this menu to assign Relay Module device addresses and specific relay numbers, and Powerline Carrier unit numbers. The  
system is based on predefined module addresses for 4204 and 4229 modules. Refer to the table shown at the “Module  
Address” prompt on the next page and set the modules’ addresses (via module DIP switches) accordingly.  
The following table shows how these outputs are identified.  
Output Identification  
This output…  
is identified by…  
Relays  
the Relay Module’s device address and the relay position on that module (i.e. the physical relay  
number, 1-4, on that module).  
X-10 Device  
Built-in Outputs  
a house ID (entered in data field *27) and the unit number of the device.  
the output number assigned, 17 for Trigger 1 and/or 18 for Trigger 2.  
This is the logical (or reference) relay number as used in the  
system. Relays and X-10 devices are numbered 01-16; the on-  
board triggers are numbered 17 and 18 and can be programmed  
for inverted output, if required.  
Device Output Number  
FA168CPS:  
01-16 = relays/X-10  
17, 18 = on-board triggers  
ENTER OUTPUT NO.  
00 = QUIT  
xx  
FA148CP:  
01-08 = relays/X-10  
17, 18 = on-board triggers  
[] to continue  
00 to quit  
(prompt appears only for Triggers 17 and 18)  
Selecting 0 (no) sets the output level normally high (default  
setting).  
Output Normally Low  
0 = no (standard default)  
1 = yes  
17 OUT NORM LOW  
0 = NO 1 = YES  
0
Selecting 1 (yes) sets the output normally low.  
Output Trigger 17 can be used for resetting 4-wire smoke  
detectors by connecting it to the negative power terminal of the  
smoke detector, selecting 1 at this prompt, and setting as zone  
type 54, fire zone reset, in *80 Menu mode.  
[] to continue  
After entry, display returns to Output Number prompt. Use *80  
Menu mode to program the function of the trigger.  
24 –  
 
Select whether this is a relay or a Powerline Carrier (X-10)  
device.  
If Powerline Carrier is selected, go to “A” prompt.  
If relay is selected, skip to “B” prompt.  
Output Type  
0 = delete  
1 = relay on 4204/4229  
module  
XX OUTPUT TYPE  
DELETE  
0
2 = Powerline Carrier device  
(X-10)  
[] to continue  
(prompt appears if X-10 is selected)  
Enter the unit code (set at the device) and press [].  
The system returns to the Output Number prompt.  
A”  
Unit Number  
01-16 = predefined address  
[] to continue  
XX UNIT No.  
yy  
yy  
(prompt appears if relay is selected)  
Enter the predefined address for this module as listed below.  
Make sure the module’s DIP switches are set to the selected  
address.  
B”  
Module Address  
07-15 = predefined address  
[] to continue  
XX MODULE ADDR  
07-15  
Module Addresses  
Address  
Module  
07  
1st 4229 (with zones 09-16)  
08  
2nd 4229 (with zones 17-24)  
3rd 4229 (with zones 25-32)  
4th 4229 (with zones 33-40)  
5th 4229 (with zones 41-48)  
1st 4204  
09†  
10†  
11†  
12  
13  
2nd 4204  
3rd 4204  
4th 4204  
14†  
15†  
† These addresses apply to FA168CPS only.  
This is the actual (or physical) relay number with respect to the  
Relay Module upon which it is located. For 4204 modules, relay  
numbers are 1-4. For 4229 modules, relay numbers are 1-2.  
The system returns to the Output Number prompt for  
programming the next device.  
Relay Position  
1-4 = relay position  
[] to continue  
XX REL POSITION  
1-4  
zz  
80 OUTPUT FUNCTION MENU MODE  
(press 80 while in Programming mode) The Output Definition Worksheet is on page Error! Bookmark not defined..  
Use this mode to program output function definitions (up to 48 functions) that provide automated control of any of the output  
Each output definition is identified  
devices, based on events occurring on individual zones or zones with certain zone types.  
by an output function number, and includes the following components:  
Output Definition Components  
Component  
Output Function No.  
Activated By  
Event  
Description  
A reference number that defines an output’s characteristics.  
Determines whether the initiating event occurs on a zone, a zone list, or a zone type.  
Event that triggers the output action. Can be an event occurring on a specific zone number or a  
zone list, or a specific zone type.  
Partition  
If the output is activated by zone type, this defines the partition in which the programmed event is  
to cause the device action.  
Output Action  
Defines the action of the relay/X-10 device when the defined event occurs. Can close for 2  
seconds, stay closed until reset, continuously pulse (1-second close-open-close-open, etc.),  
toggle the device state, or activate for a defined duration (set in data field *177).  
Assigns this function to a specific output number (defined in *79 Menu Mode). This is the output  
number that will perform this function upon the triggering event. Note that each defined function is  
associated with only one output number. This means that if more than one output device needs to  
perform this particular function, you need to define another output function number with the same  
attributes, but assign the appropriate output number. (i.e. output devices can be assigned more  
than one function number, but each function number can only be assigned a single output  
number.  
Output No.  
For example, if you want to pulse a strobe light upon fire alarms on zone 4 using a relay mapped to output number 2 (as  
programmed in *79 Menu Mode), program the following in *80 Menu Mode:  
Prompt  
Entry  
Output Funct. #  
Activated By:  
Enter Zn No.  
Output Action  
Output Number  
=
=
=
=
=
01 (assuming this is the first output function)  
3 (zone number)  
04 (requires 2-digit zone numbers)  
3 (continuous pulse)  
02 (device mapped in *79 Menu Mode)  
25 –  
 
80 Menu Mode  
Enter the output function number to be defined (or 00 to exit)  
Output Function No.  
(FA168CPS: 01-48  
(FA148CP: 01-24)  
Output Funct. #  
(00 = Quit)  
01  
[] to continue; 00 to quit  
This screen displays a summary of the current output  
programming (for this example, Zone List has been selected-this  
is the default screen).  
Summary Screen  
[] to continue  
01 A E P Trig  
?00 0 0 – ZL=00  
A = Output Action; E = Triggering event; P = Partition;  
Trig = Trigger type  
NOTE: A question mark in the summary screen indicates that the  
device number shown has not been mapped. Use *79 Menu  
mode to map the device.  
Select where the initiating event for this output definition is to  
occur as follows:  
If you enter “0,” the following prompt appears:  
Activated By  
01 Activated By:  
Zone List  
0 = delete  
1 = zone list (go to “A”)  
2 = zone type (go to “B”)  
3 = zone number (go to “C”)  
[] to continue  
Delete?  
0 = NO, 1 = YES  
Press 1 to delete this output definition. The system deletes the  
output function and any previous programming.  
A”  
(prompt appears if zone list was selected)  
Zone List  
01-08 = zone list  
[] to continue  
Enter the desired zone list number associated with this output  
number. At the ENTER EVENT prompt, enter the zone list event  
that will activate this output  
01 Zn List  
1
NOTE: Do not use pager zone lists 09-12 in output definitions.  
Enter Event  
Alarm  
0 = restore; 1 = alarm;  
2 = fault; 3= trouble  
1
NOTE: For alarm, fault, and trouble, an event on ANY zone in the  
list activates the output, but ALL zones in the list must be  
restored before the output is restored.  
Press [ ] to continue and skip to the “Output Action” prompt.  
B”  
(prompt appears if zone type was selected)  
Enter the desired zone type associated with this output number.  
At the PARTITION prompt, enter the partition in which this zone  
type will occur.  
Zone Type  
See list at right for available  
zone types.  
01 Enter Zn type  
Perimeter  
03  
CHOICES FOR ZONE TYPES:  
00 = Not Used  
05 = Day/Night  
06 = 24 Hr Silent  
07 = 24 Hr Audible  
08 = 24 Hr Aux  
09 = Fire  
12 = Monitor Zone  
01 = Ent/Exit #1  
02 = Ent/Exit #2  
03 = Perimeter  
14 = Carbon Monoxide††  
16 = Fire w/verification  
23 = No Alarm Response  
24 = Silent Burglary  
04 = Interior Follower  
10 = Interior w/Delay 77 = Keyswitch Zone  
81 = AAV Monitor Zone  
90-91 = Configurable  
CHOICES FOR SYSTEM OPERATION:  
20 = Arming–Stay  
21 = Arming–Away  
22 = Disarming  
36 = **At Bell Timeout*** 58 = Duress  
38 = Chime  
60 = AAV  
61 = AVS/GSMV session begin§  
62 = AVS/GSMV session end §  
39 = Any Fire Alarm  
40 = Bypassing  
31 = End of Exit Time  
32 = Start of Entry Time 41 = **AC Power Failure 66 = Function Key†  
33 = Any Burglary Alarm 42 = **System Battery Low 67 = Bell Fail  
43 = Comm. Failure  
52 = Kissoff  
54 = Fire Zone Reset  
68 = Telco Line Cut  
78 = Keyswitch Red LED  
79 = Keyswitch Green LED  
** Use 0 (Any) for Partition No. (P) entry.  
*** Or at Disarming, whichever occurs earlier.  
† Use *57 Menu Mode to assign the function key (function “07”).  
†† when used with an output function, the carbon monoxide zone type  
activates upon CO alarms only. Does not activate for trouble conditions.  
§ automatically set when appropriate AVS Quick Command performed.  
Note: In normal operation mode:  
Code + # + 7 + NN Key Entry starts Device NN.  
Code + # + 8 + NN Key Entry stops Device NN.  
Enter the partition in which this zone type will occur.  
01 Partition  
0 = any partition; 1 = partition 1;  
2 = partition 2; 3 = common  
Any partition  
0
Press [ ] to continue and skip to the “Output Action” prompt.  
26 –  
 
(prompt appears if zone number was selected)  
Enter the desired zone number associated with this output  
number. At the ENTER EVENT prompt, enter the zone event  
that will activate this output.  
C”  
Zone Number  
Press [ ] to continue.  
01 Enter Zn No.  
12  
01 Enter Event  
0 = restore; 1 = alarm/fault/trouble  
Restore  
0
Press [ ] to continue to the “Output Action” prompt  
Enter the desired device action.  
Output Action  
0 = off  
1 = Close for 2 seconds  
2 = Stay Closed  
01 Output Action  
Close for 2 sec  
1
3 = Pulse on & off (1 sec  
ON, 1 sec OFF)  
4 = Change Device State  
5 = Duration 1 (see data  
field *177)  
6 = Duration 2 (see data  
field *177)  
Press [ ] to continue.  
Enter the device output number (programmed in *79 Menu  
Mode) you want associated with this output.  
Output Number  
Enter Output No.  
R02  
01-16 = FA168CPS outputs  
01-08 = FA148CP outputs  
17-18 = on-board triggers  
02  
Press [ ] to continue.  
A summary screen appears showing the programmed settings.  
Press [] to return to OUTPUT FUNCTION NUMBER prompt  
Summary Screen  
02 A E P TRIG  
R02 1 1 3 ZL=00  
Press [ ] to continue.  
81 ZONE LIST MENU MODE  
(press *81 while in Programming mode) The Zone List Worksheet is on page Error! Bookmark not defined..  
select an appropriate  
Zone lists let you group individual zones for use with certain system actions. Using this mode, simply  
zone list number, then add the desired zone numbers to be included in that list.  
The following table shows the available zone lists and their purposes:  
List No.  
1, 2  
3
4
5
Used for…  
general purpose (GP)  
chime-by-zone (see field *26 to enable option)  
cross zones (see note at right)  
night stay zones  
Notes  
Any list may include any or all of the system's zone numbers.  
A zone list can be assigned to more than one output relay.  
Zone List 4: When creating zone list 4 for cross zoning,  
include only zones assigned to zone types 3, 4, or 5. Do not  
include zones that have delays (entry/exit zones, interior  
w/delay) or 24-hour zones, as these zone types may produce  
unpredictable operation and may not function as intended.  
See field *85 for Cross Zone Timer option.  
6
general purpose  
SIA-Compliant: dial delay disable  
general purpose  
SIA-Compliant: unlimited reports  
general purpose  
zones that activate Pager 1  
zones that activate Pager 2  
zones that activate Pager 3 (FA168CPS)  
zones that activate Pager 4 (FA168CPS)  
7
8
9
10  
11  
12  
Zone List 6: SIA-Compliant: See field *50 for Dial Delay Disable  
option.  
Zone List 7: SIA-Compliant: See field *93 for Unlimited Reports  
option.  
*81 Menu Mode  
Enter the Zone List Number to program (or 00 to quit). Press [ ]  
to advance.  
In the following displays, zone list 01 has been selected.  
Zone List Number  
01-12 = zone list number  
[] to continue  
Zone List No.  
(00 = Quit)  
01  
Enter each zone number to add to the zone list, followed by  
pressing [ ] (example, 01 , 02 , 03 ). After all zones are  
entered, press 00 to continue.  
IMPORTANT: Do not include fire zones in zone lists that are  
used to STOP device actions.  
† FA168CPS = 01-64; FA148CP = 01-06, 09-34, 49-56.  
Zone Number  
01-64 = zone numbers  
followed by [] to  
accept each zone  
00 to continue  
01 Enter Zn Num.  
(00 = Quit)  
00  
To delete the zone list, enter 1. All zones in the zone list will be  
deleted automatically and the system returns to the Zone List  
No. prompt.  
Deleting Zone Lists  
0 = don’t delete list  
1 = delete this zone list  
[] to continue  
01 Del Zn List?  
0 = No 1 = Yes  
0
To save the zone list, enter 0.  
27 –  
 
To save the zone list, enter 0 and the system returns to the Zone  
List No. prompt.  
To delete a zone or zones in a zone list, enter 1 to continue.  
Deleting a Zone  
0 = don’t delete zones  
1 = go to next prompt to  
delete zones  
01 Delete Zone?  
0 = No 1 = Yes  
0
[] to continue  
Enter each zone to be deleted from the list, followed by [ ]. After  
Delete the Zone  
01-64 = zones to be  
deleted from list  
followed by [] to  
accept each zone  
00 to continue  
01 Zn to Delete?  
(00 = Quit)  
all zones to be deleted are entered, enter 00 to return to the  
Zone List No. prompt so that another list can be programmed, if  
desired.  
00  
† FA168CPS = 01-64; FA148CP = 01-06, 09-34, 49-56.  
82 ALPHA DESCRIPTOR MENU MODE  
The system lets you assign zone descriptors for protection zones, keypad panics, and RF receiver supervision faults. Each  
description can be composed of a combination of up to 3 words selected from a vocabulary of words stored in memory (see  
Alpha Vocabulary List page). In addition, up to 10 installer-defined words can be added to those already in memory, plus 3  
additional words can be assigned as partition descriptors. Thus, when an alarm or trouble occurs in a zone, an appropriate  
description for that zone's location can be displayed at the keypad. Zone descriptors are recommended for systems using Alpha  
display keypads, and are necessary if a 4286 Phone Module is used.  
NOTE: You can also enter zone descriptors when the zone is being defined in 56 Menu mode.  
4286 NOTE: If using a 4286 Phone Module, select from those words in the Alpha Vocabulary List shown in boldface type.  
The phone module will not provide annunciation of the other words.  
If a Phone Module is added to an existing system, the Alpha descriptors presently in the system should be reprogrammed,  
selecting from those words shown in boldface type in the Alpha Vocabulary List. The phone module will not provide  
annunciation of any other words.  
82 Menu Mode  
The “Program Alpha ?” prompt will appear. Press 1 to continue.  
Program Alpha  
0 = no (quit Alpha mode)  
1 = yes  
Program Alpha ?  
0=No, 1=Yes 00  
[] to continue  
The “Custom Words” prompt will appear.  
Custom Words  
0 = no  
1 = yes  
Custom Words ?  
0=No, 1=Yes 00  
Press 0 to program standard alpha descriptors from the fixed  
vocabulary. The system then automatically displays the descriptor  
for zone 1.  
Press 1 to define custom words (see “Adding Custom Words”).  
Note that this is a “Summary mode,” and that no entries can be  
made. Entries can be made only when the display contains a  
flashing cursor, which signifies Edit mode.”  
To exit the Alpha Descriptor mode, press + 0 + 0 at the  
summary display.  
Summary Screen  
ZN 01  
[] to continue to edit mode  
[#] = return to Program  
Alpha prompt (to quit)  
Descriptor screen for zone 1 appears. To program a descriptor  
(up to 3 words) for a zone, do the following:  
1. Enter the desired zone number (existing descriptor, if any, is  
displayed) and press [], then enter the zone number again to  
start edit mode (flashing cursor appears).  
2. a. Press [#] plus the 3-digit number from the Alpha Vocabulary  
List for the first word.  
b. Press [6] to accept the word and move the cursor for the next  
word in the descriptor.  
Edit Mode Flashing  
Cursor  
ZN 01  
to edit = zone number then  
[], then zone  
number again  
6 = save word and go to  
next word in a  
descriptor  
3. Repeat steps 2a and 2b for the second and third words (if used).  
4. When all words for that descriptor have been entered, press [8]  
to save the descriptor for that zone. The summary screen  
displays for that zone and the flashing cursor disappears.  
5. Press [] at the summary screen and repeat steps 1-4 to  
assign a descriptor for the next zone.  
8 = save descriptor and go  
to next zone  
[#] = return to Program  
Alpha prompt (to quit)  
6. When all descriptors have been entered, press [#]) at the last  
descriptor summary screen to return to the PROGRAM  
ALPHA? prompt. Enter 0 (no) at the prompt to exit this mode  
and return to Data Field mode.  
28 –  
 
EXAMPLE: “BACK DOOR”  
Descriptor Example  
EXAMPLE:  
(a)  
a. From the list, BACK = 013, so, after entering the zone number  
to be edited (step 1), enter #013. If you accidentally enter the  
wrong word, simply press [#] plus the correct 3-digit number for  
the word you want.  
ZN 01  
B ACK  
b. Press [6] to accept the selected word and continue to the next  
word. (if this is the only word you are using for the descriptor  
press [8] to save it).  
(b)  
ZN 01 BACK  
c. Enter the 3-digit number for the next word, “DOOR,” whose  
number is “057.” Enter # 0 5 7.  
d. Because this is the last word in the example descriptor, press  
[8] to save it. (If there was a third word in the descriptor, press  
[6] to accept the selected word and continue to the third word.)  
(c)  
ZN 01 BACK  
D OOR  
The summary screen displays with the selected descriptor.  
(d)  
ZN 01 BACK  
DOOR  
The flashing cursor disappears, indicating that the word(s) are  
saved for that zone, as shown in the summary display at the left.  
Summary Screen  
[] = to enter another zone  
number  
[#] = return to Program  
Alpha prompt (to quit)  
ZN 01 BACK  
DOOR  
]  
To enter a descriptor for the next zone, press [ plus the  
desired zone number. The summary display appears. Repeat  
the previous steps to enter the descriptor for the zone.  
Adding Custom Words (will not be annunciated by 4286 Phone Module)  
You can add up to 10 installer-defined words to the built-in vocabulary, which can then be used when programming zone  
descriptors. Each of the 10 words can actually consist of a word string of one or more words, but no more than ten  
characters can be used for each word or word string.  
When adding custom words, the keypad keys perform the following functions:  
[4] Moves cursor one space to the left.  
[6] Moves cursor one space to the right.  
[8] Saves the new word in the system's memory.  
1. Select Custom Word mode (enter 1) when the prompt “CUSTOM WORD ?” is displayed.  
2. Enter the number (01–10†) of the custom word or word string to be created, corresponding to index numbers 245 - 254  
respectively (for example, if you are creating the first custom word or word-string, enter 01, for the second, enter 02, etc.).  
A cursor will now appear at the beginning of the second line.  
† or 11, 12, 13 for partition 1, partition 2 and common lobby descriptors respectively. See Assigning Partition  
Descriptors paragraph below.  
NOTE: Custom words 8, 9, and 10 are “reminder words” that are programmed using Scheduling Mode.  
3. Refer to the Character List of letters, numbers, and symbols on a following page.  
Press [#], followed by the two-digit entry for the first letter you would like to display (e.g., # 65 for “A”).  
The cursor moves to the right, in position for the next character.  
To delete a character, simply enter the SPACE character (#32) at the unwanted character’s location..  
4. Repeat Step 3 to create the desired word(s). Note that the “4” key can be used to move the cursor to the left, if necessary.  
Remember, no word or word-string can exceed 10 characters (except custom message/partition descriptor word numbers  
11, 12, and 13, which can be a maximum of 16 characters).  
5. When the word is complete, press the [8] key to save the custom word(s) and return to the “CUSTOM WORD ?” display.  
Repeat Steps 2–5 for other custom words to be entered. To change a custom word, just overwrite it. When all words have  
been programmed, press [0] to return to the Descriptor entry. The custom word(s) will be automatically added to the built-  
in vocabulary.  
Assigning Partition/Custom Message Descriptors  
FA148CP: You can create a custom message display that appears on alpha keypads instead of “System Ready.” To assign a  
custom message, use word number 11 as described below.  
FA168CPS: You can assign a partition descriptor (up to 16 characters) for each partition plus the common lobby. The system  
displays the appropriate partition’s word instead of “DISARMED READY TO ARM.”  
Use the same procedure as for adding custom words (described above), but use these word numbers in step 2:  
11 = partition 1 ___________________________________________  
12 = partition 2 ___________________________________________ (FA168CPS only)  
13 = common lobby ________________________________________ (FA168CPS only)  
Once a custom word is entered in any of these word locations (11-13), the system displays the appropriate partition’s word  
instead of the default “DISARMED READY TO ARM” message.  
29 –  
 
ALPHA VOCABULARY LIST (For Entering Zone Descriptors)  
000 (Word Space)  
A –  
001 AIR  
002 ALARM   
004 ALLEY  
005 AMBUSH  
006 AREA  
007 APARTMENT  
009 ATTIC ∗  
010 AUDIO  
L –  
R –  
155 RADIO  
V –  
209 VALVE  
210 VAULT  
212 VOLTAGE  
W –  
057 DOOR ∗  
059 DOWN  
060 DOWNSTAIRS  
061 DRAWER  
062 DRIVEWAY  
064 DUCT  
E –  
065 EAST  
066 ELECTRIC  
067 EMERGENCY ∗  
068 ENTRY  
069 EQUIPMENT  
071 EXIT ∗  
072 EXTERIOR  
F –  
073 FACTORY  
075 FAMILY  
076 FATHERS  
077 FENCE  
079 FIRE ∗  
080 FLOOR ∗  
081 FLOW  
106 LAUNDRY ∗  
107 LEFT  
108 LEVEL  
109 LIBRARY ∗  
110 LIGHT  
111 LINE  
113 LIVING ∗  
114 LOADING  
115 LOCK  
116 LOOP  
117 LOW  
118 LOWER  
M –  
119 MACHINE  
121 MAIDS  
156 REAR  
157 RECREATION  
159 REFRIGERATION  
160 RF  
161 RIGHT  
162 ROOM ∗  
163 ROOF  
213 WALL  
214 WAREHOUSE  
216 WEST  
217 WINDOW ∗  
219 WING  
220 WIRELESS  
X –  
222 XMITTER  
Y –  
223 YARD  
Z –  
S –  
164 SAFE  
B –  
165 SCREEN  
166 SENSOR  
167 SERVICE  
168 SHED ∗  
169 SHOCK  
012 BABY ∗  
013 BACK ∗  
014 BAR  
016 BASEMENT ∗  
017 BATHROOM ∗  
018 BED  
019 BEDROOM ∗  
020 BELL  
021 BLOWER  
022 BOILER  
023 BOTTOM  
025 BREAK  
224 ZONE (No.)  
225 ZONE ∗  
170 SHOP ∗  
171 SHORT  
122 MAIN ∗  
123 MASTER ∗  
125 MEDICAL ∗  
126 MEDICINE  
128 MONEY  
129 MONITOR  
130 MOTHERS  
131 MOTION ∗  
132 MOTOR  
N –  
226  
227  
0
1
173 SIDE ∗  
174 SKYLIGHT  
175 SLIDING ∗  
176 SMOKE ∗  
178 SONS  
179 SOUTH  
180 SPRINKLER  
182 STATION  
184 STORE  
228 1ST ∗  
229  
230 2ND ∗  
231  
232 3RD ∗  
233  
234 4TH  
235  
236 5TH  
237  
238 6TH  
239  
240 7TH  
241  
242 8TH  
243  
2
082 FOIL  
3
083 FOYER  
084 FREEZER  
085 FRONT ∗  
G –  
089 GARAGE ∗  
090 GAS  
091 GATE  
092 GLASS  
093 GUEST  
094 GUN  
026 BUILDING  
C –  
028 CABINET  
029 CALL  
030 CAMERA  
031 CAR  
033 CASH  
4
134 NORTH  
135 NURSERY  
O –  
136 OFFICE ∗  
138 OPEN ∗  
139 OPENING  
140 OUTSIDE  
142 OVERHEAD  
P –  
143 PAINTING  
144 PANIC ∗  
145 PASSIVE  
146 PATIO ∗  
147 PERIMETER  
148 PHONE  
150 POINT  
151 POLICE ∗  
152 POOL ∗  
153 POWER  
185 STORAGE ∗  
186 STORY  
5
190 SUPERVISED ∗  
191 SUPERVISION  
192 SWIMMING  
193 SWITCH  
T –  
194 TAMPER  
196 TELCO  
197 TELEPHONE  
199 TEMPERATURE  
200 THERMOSTAT  
201 TOOL  
202 TRANSMITTER  
U –  
205 UP  
206 UPPER  
207 UPSTAIRS ∗  
208 UTILITY ∗  
6
034 CCTV  
035 CEILING  
036 CELLAR  
037 CENTRAL  
038 CIRCUIT  
040 CLOSED ∗  
046 COMPUTER  
047 CONTACT  
D –  
048 DAUGHTERS  
049 DELAYED  
050 DEN ∗  
051 DESK  
7
8
H –  
095 HALL ∗  
096 HEAT  
098 HOLDUP  
099 HOUSE ∗  
100 INFRARED  
101 INSIDE ∗  
102 INTERIOR  
103 INTRUSION  
J –  
9
244 9TH  
245 Custom Word #1  
246 Custom Word #2  
247 Custom Word #3  
248 Custom Word #4  
249 Custom Word #5  
250 Custom Word #6  
251 Custom Word #7  
252 Custom Word #8  
253 Custom Word #9  
254 Custom Word #10  
052 DETECTOR ∗  
053 DINING ∗  
054 DISCRIMINATOR  
055 DISPLAY  
104 JEWELRY  
K –  
105 KITCHEN ∗  
Note: Bulleted () words in boldface type are those that are also available for use by the 4286 Phone Module. If using a  
Phone module, and words other than these are selected for Alpha descriptors, the module will not provide  
annunciation of those words.  
Italicized words followed by an asterisk indicate those words supported by the 6160V/6150V Voice Keypads  
CHARACTER (ASCII) CHART (For Adding Custom Words)  
32 (space)  
41  
42  
43  
44  
45  
46  
47  
48  
49  
)
50  
51  
52  
53  
54  
55  
56  
57  
58  
2
3
4
5
6
7
8
9
:
59  
60  
61  
62  
63  
64  
65  
66  
67  
;
68  
69  
70  
71  
72  
73  
74  
75  
76  
D
E
F
G
H
I
J
K
L
77  
78  
79  
80  
81  
82  
83  
84  
85  
M
N
O
P
Q
R
S
T
86  
87  
88  
89  
90  
V
W
X
Y
Z
33  
34  
35  
36  
37  
38  
39  
40  
!
"
#
$
%
&
'
*
+
,
.
/
0
1
<
=
>
?
@
A
B
C
(
U
30 –  
 
SETTING SCHEDULES  
(Installer Code + [#] + [6] [4])  
The system provides schedules, which can be used to automatically control 11 types of system events at pre-defined times.  
Some events are reserved for the installer only.  
FA168CPS: Provides up to 32 schedules: 16 schedules for use by the end-user, 16 for use by the installer.  
FA148CP:  
Provides up to 8 schedules: 4 schedules for use by the end user, 4 for use by the installer.  
NOTES:  
The master code can only access schedules 01-16 (FA148CP = 01-04) and events 00-07.  
System clock must be set before schedules can take effect.  
Programmed schedules do not take effect until the next scheduled “start” time. (e.g., if programming a schedule time window  
for 8AM to 5PM, the schedule does not take effect until 8AM after the schedule has been programmed.)  
Schedule Mode  
Enter the desired schedule number.  
To Quit, enter 00.  
Schedule Number  
FA168CPS  
01-16 = end-user schedules  
17-32 = installer-only  
FA148CP  
ENTER SCHED NO.  
00=QUIT  
00  
01-04 = end-user schedules  
05-08- = installer-only  
[] to continue  
Enter the desired event number for event you want to occur at a  
specified time.  
Events 10-11 are reserved for the installer only.  
Enter Event  
ENTER EVENT  
00 = clear event  
01 = Relay On/Off  
02 = User Access  
Latch key report (option 03) is sent to all pagers in the user’s  
partition and is active only when the system is armed (message  
sent is 777-7777). User must be enabled for paging (see User  
Attributes in System Operation section).  
03 = Latch Key Report to  
Pager  
04 = Forced Stay Arming†  
05 = Forced Away Arming†  
06 = Auto Disarm  
† Forced bypass is automatically enabled regardless of setting  
in field *23.  
†† If selected, system displays custom words 8, 9, and 10 at  
defined time. Can be used as installer’s reminder message to  
the end user.  
07 = Display “Reminder”  
10 = Display custom words ††  
11 = Periodic Test Report†††  
Press [] to continue.  
††† See key commands in Test Report Code data field *64  
section to quickly set periodic test reporting intervals.  
NOTE: Events 07 and 10 cause the keypad to beep every 30 seconds  
when messages are displayed. Stop the beeps by pressing any key.  
(For event 01-relay on/off)  
Device Number  
FA168CPS:  
01-18 = device number  
FA148CP: 01-08, 17, 18  
Press [] to continue.  
DEVICE NUMBER  
XX  
Enter the physical device number as programmed in 79 Menu  
Mode, then press [*] to continue to the “Start” prompt.  
Device numbers 17 and 18 designate built-in triggers 1 and 2  
respectively.  
(For event 02-user access)  
Group Number  
GROUP NUMBER  
X
1-8 = group number  
Press [] to continue to the  
“Start” prompt.  
(FA168CPS only; for events 03-07, 10)  
Partition  
0 = all partitions  
1 = partition 1  
PARTITION  
X
2 = partition 2  
3 = common  
Press [*] to continue to the  
“Start” prompt.  
Enter the event’s start time and days of the week to occur.  
To select days, position the cursor under the desired days using  
the [] key to move forward, then press “1” to select the day.  
Start Time  
START  
SMTWTFS  
01-12 = hour  
HH MMAM 0 0 1 0 0 0 0  
00-59 = minute  
0 = AM; 1 = PM  
Days = place “1” under days  
Press [] to continue.  
(For events 01-relay on/off; 02-user access; 03-latch key report)  
Enter the event’s stop time and days of the week to occur.  
To select days, position the cursor under the desired days using  
the [] key to move forward, then press “1” to select the day.  
Stop Time  
STOP  
SMTWTFS  
01-12 = hour  
HH MMAM 0 0 1 0 0 0 0  
00-59 = minute  
0 = AM; 1 = PM  
Days = place “1” under days  
Press [] to continue.  
31 –  
 
Enter the desired repeat option for this schedule.  
e.g., To make a schedule that happens everyday you would  
select all days with a repeat count of 1. To make a schedule that  
runs for one week then stops, select everyday with a repeat  
count of 0.  
Repeat Option  
REPEAT OPTION  
0 = do not repeat  
0-4  
X
1 = repeat weekly  
2 = repeat biweekly (every  
other week)  
3 = repeat every third week  
4 = repeat every fourth week  
Press [] to continue.  
(For events 01 and 11)  
Randomize  
RANDOMIZE  
0=NO 1=YES  
If selected, the scheduled start and stop times will vary within 60  
minutes of the “hour” time. For example, if a schedule is set to  
start at 6:15pm, it will do so the first time 6:15pm arrives, but on  
subsequent days it will start anytime between 6:00 and 6:59 p.m.  
0 = no  
X
1 = yes  
Press [] to continue and  
return to ENTER SCHED  
NO. prompt to program the  
next schedule.  
NOTE: Do not use the random option if the start and stop times  
are within the same “hour” setting, otherwise unpredictable  
results may occur (e.g., the randomized stop time may occur  
before the start time).  
AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS  
Applies to an AVS system using an ECP connection to the control.  
1. Install the AVS module according to its instructions.  
2. Use one of the control’s AVS Quick Program commands as follows (see Quick Program Command Results below for  
results of each command):  
installer code + [#] + 0 + 3: enable AVS operation without panel sounds on the AVST speaker  
installer code + [#] + 0 + 4: enable AVS operation and enable panel sounds on the AVST speaker  
3. Use data field 55 Dynamic Signaling Priority to select the desired reporting paths (phone line and/or GSMV) and path for  
AAV communication.  
4. To undo the Quick Command programming, use the following commands:  
installer code + [#] + 0 + 5: remove all options that were set if [#] + 03 quick command was performed  
installer code + [#] + 0 + 6: remove all options that were set if [#] + 04 quick command was performed  
Quick Program Command Results  
When either the #03 or #04 Quick Program command is used, the following are automatically programmed and no longer  
available for other control panel purposes.  
Pre-Programmed  
Output Function No.  
(80 mode)  
#03 Command  
FA168CPS  
22 (zone type 60, relay 07) 46 (zone type 60, relay 15) Same as #03 plus:  
23 (zone type 61, relay 08) 47 (zone type 61, relay 16) 17 (zone type 14, relay 05) 41 (zone type 14, relay 13)  
24 (zone type 62, relay 08) 48 (zone type 62, relay 16) 18 (zone type 22, relay 05) 42 (zone type 22, relay 13)  
19 (zone type 39, relay 06) 43 (zone type 39, relay 14)  
#04 Command  
FA168CPS  
Same as #03 plus:  
FA148CP  
FA148CP  
20 (zone type 33, relay 06) 44 (zone type 33, relay 14)  
21 (zone type 22, relay 06) 45 (zone type 22, relay 14  
Output Relay No.  
(79 mode)  
07 (addr 08, relay pos 2)  
08 (addr 08, relay pos 1)  
15 (addr 11, relay pos 2)  
16 (addr 11, relay pos 1)  
Same as #03 plus:  
05 (addr 08, relay pos 4)  
06 (addr 08, relay pos 3)  
Same as #03 plus:  
13 (addr 11, relay pos 4)  
14 (addr 11, relay pos 3)  
Same as #03 command  
Protection Zone  
(56/58 mode)  
Device Address  
Data Field 91  
4229 zn 24 (zt 81, addr 08) 4229 zn 48 (zt 81, addr 11) Same as #03 command  
address 08 (AVS module)  
AAV enabled  
address 11 (AVS module)  
AAV enabled  
Same as #03 command  
AAV enabled  
Same as #03 command  
AAV enabled  
SETTING THE REAL-TIME CLOCK  
IMPORTANT: The Real-Time Clock must be set before the end of the installation.  
NOTE: All partitions must be disarmed before the date/time can be set.  
1. Master Code + [#] + [6] [3]  
2. Press [] when the time/date is displayed.  
A cursor appears under the first digit of the hour.  
To move cursor ahead, press []. To go back, press [#].  
Enter the 2-digit hour setting.  
Enter the 2-digit minute setting.  
Press [1] for PM or [2] for AM.  
Enter the last two digits of the current year.  
Enter the 2-digit month setting.  
Enter the 2-digit day setting.  
3. To exit, press [] when cursor is at the last digit, or wait 30 seconds.  
32 –  
 
29 COMMUNICATION DEVICE MENU MODE (Pass-Through Programming)  
This mode is for programming an IP, GSM, or IP/GSM Communicator Module using an alpha keypad. Alternatively, these  
options can be programmed via the AlarmNet Direct website. After programming is complete, the module must be registered  
with AlarmNet before reporting via the communication device can occur. Refer to the device’s instructions for registration  
procedures.  
NOTE: The module must be set to device address 3.  
IMPORTANT: The use of an IP/GSM Communicator Module  
requires an AlarmNet–I account. Please obtain the account  
information from the central station prior to programming this  
module.  
Using an Alpha Keypad as a 7720P Programming Tool  
READY  
ARMED  
When programming with 29 menu mode, the alpha  
keypad mimics the functions of the 7720P Programming  
Tool. See figure to right and table below for 7720P key  
functions. Each key has two possible functions: a normal  
function and a SHIFT function.  
SHIFT  
FUNCTION  
WHEN LIT  
R
A
D
S
B
C
F
X
Normal functions: The numeric values labeled directly  
on the keys and the left-hand functions shown in  
diagram on the ABC keys. To perform a normal key  
function, simply press the desired key.  
SHIFT functions: Those functions shown in diagram  
above the numerical keys and the right-hand functions  
shown on the ABC keys. To perform a SHIFT key  
function, press SHIFT key (D key), then press the  
desired function key (shift function is indicated by the lit  
READY LED).  
BS/ESC  
1
4
7
3
6
9
(A)  
(B)  
(C)  
(D)  
2
E
/
5
T
N / Y  
8
SPACE  
ENTER  
SHIFT  
0
#
FA560  
FA560KP-005-V0  
7720P Emulation Template for Alpha Keypads  
29 IP/GSM Program Mode  
Press 29 while in Data Field Programming mode. The following prompts appear.  
If using a communication device, enter 1 at this prompt and  
Enable IP/GSM?  
0 = no, not using IP or GSM;  
1 = yes using IP and/or  
GSM module  
ENABLE IP/GSM?  
0=No, 1=Yes  
enter 1-Prog at the next prompt to program and register the  
device. Use the communication device’s Installation Guide for  
details of the device’s programming prompts and instructions for  
registration.  
[] to continue  
[Default = 0 (no IP and/or GSM)]  
Select whether you want to program the communication device  
or enter the device’s diagnostic mode.  
Programming /  
1=PROG 2=DIAG  
0=QUIT  
Diagnostics Select  
1= Prog (program the  
IP/GSM options)  
2 = Diag (enter diagnostic  
mode)  
Diagnostic Mode Note: Diagnostic mode option available only  
for communicators with firmware version 2.4.16 or higher.  
0 = Quit; returns to data field  
programming mode  
Normal and SHIFT key Functions While in 29 Menu Mode  
Key Normal Key Function  
(A) = BS/ESC [BS]: Press to delete entry  
SHIFT Key Function  
[ESC]: Press to quit Program Mode  
Also, can reset EEPROM defaults  
(B) = /↑  
(C) = N/Y  
(D) = SHIFT  
[]: Scroll down programming  
[]: Scroll up programming  
[N]: Press for "NO" answer  
[Y]: Press SHIFT-Y for "YES" answer  
Press before pressing a SHIFT key function. Will light READY LED. LED goes out once a  
key is pressed. Press again for each SHIFT function desired.  
1/A  
2/B  
3/C  
4/D  
5/E  
6/F  
7/S  
8/T  
[1]: For entering the number 1  
[2]: For entering the number 2  
[3]: For entering the number 3  
[4]: For entering the number 4  
[5]: For entering the number 5  
[6]: For entering the number 6  
[7]: For entering the number 7  
[8]: For entering the number 8  
[9]: For entering the number 9  
[]: Used to select programming options  
[0]: For entering the number 0  
[#] / ENTER: Press to accept entries  
[A]: Used for entering C.S. ID number  
[B]: Used for entering C.S. ID number  
[C]: Used for entering C.S. ID number  
[D]: Used for entering C.S. ID number  
[E]: Used for entering C.S. ID number  
[F]: Used for entering C.S. ID number  
[S]: Press to display diagnostic status  
[T]: Press to send TEST messages  
[X]: Press to reset the IP/GSM  
9/X  
[] / SPACE  
0
[SPACE]: Not used  
[#] / ENTER  
No SHIFT function  
† Active only when the "REVIEW?" prompt is displayed  
33 –  
 
ZONE TYPE DEFINITIONS  
Zone types define the way in which the system responds to faults in each zone.  
Type 00 Zone Not Used  
Type 12 Monitor Zone  
Program a zone with this zone type if the zone is not used.  
Type 01 Entry/Exit Burglary #1  
Assign to zones that are used for primary entry and exit.  
Provides entry delay when zone is faulted if control is armed in  
the Away, Stay, or Night-Stay modes.  
Works as a dynamic monitor of a zone fault/trouble (not alarm). In  
the case of a short/open, the message, "*ALARM*-24 Hr. Non-Burg.  
-#XXX " (where XXX is the zone number) will be sent to the Central  
Station. The system keypad will display a “check” message  
indicating the appropriate zone (but keypad beeping does not  
occur). Upon restoral of the zone, the message, "*RESTORE*-24  
Hr. Non-Burg. -#XXX " will be sent to the Central Station.  
The “check” message will automatically disappear from the keypad  
dynamically, when the zone restores; a user code + off sequence is  
not needed to reset the zone.  
No entry delay provided when the panel is armed in the  
Instant/Maximum mode.  
Entry delay #1 is programmable for each partition (field *35).  
Exit delay begins whenever the control is armed, regardless of  
the arming mode selected, and is programmable (field 34).  
Faults of this zone type are independent of the system, and can  
exist at the time of arming without interference.  
Type 02 Entry/Exit Burglary #2  
Assign to zones that are used for entry and exit and require  
more time than the primary entry/exit point.  
Provides a secondary entry delay, similar to entry delay #1.  
Entry delay #2 is programmable for each partition (field *36).  
Exit delay is same as described for Type 01.  
Since this is a “trouble” zone type, do not use this zone type with  
relays set to activate upon “alarm.”  
Type 14 24 Hour Carbon Monoxide Monitor  
Assigned to any zone with a carbon monoxide detector.  
A carbon monoxide alarm produces keypad and detector sounding  
(does not affect bell output).  
Always active and cannot be bypassed.  
Type 16 Fire w/Verification  
Provides a fire alarm when zone is shorted, but only after alarm  
verified.  
Type 03 Perimeter Burglary  
Assign to all sensors or contacts on exterior doors and windows.  
Provides an instant alarm if the zone is faulted when the panel is  
armed in the Away, Stay, Night-Stay, Instant or Maximum modes.  
Type 04 Interior Follower  
Assign to a zone covering an area such as a foyer, lobby, or  
hallway through which one must pass upon entry (to and from  
the keypad).  
Provides a delayed alarm (using the programmed entry 1 time)  
if the entry/exit zone is faulted first. Otherwise this zone type  
gives an instant alarm.  
Active when the panel is armed in the Away mode.  
Bypassed automatically when the panel is armed in the Stay or  
Instant modes; if armed in Night-Stay mode, zones assigned to  
zone list 05 (night-stay zone list) are not bypassed when  
system armed in Night-Stay mode.  
Verifies alarm by resetting smoke detectors after short is detected  
(removes power 7 seconds for zone 1, 3 seconds for trigger output).  
Another short circuit within 90 seconds triggers fire alarm.  
Provides a trouble response when zone is open.  
Type 20 Arm-Stay (BR only)  
Arms the system in Stay mode when the zone is activated.  
Pushbutton units send the user number to the central station when  
arming or disarming.  
User number for button must be assigned.  
Type 21 Arm-Away (BR only)  
Arms the system in Away mode when the zone is activated.  
Pushbutton units send the user number to the central station when  
arming or disarming.  
User number for button must be assigned.  
Type 22 Disarm (BR only)  
Disarms the system when the zone is activated.  
User number for button must be assigned.  
Type 23 * No Alarm Response  
Can be used on a zone when an output relay action is desired, but  
with no accompanying alarm (e.g., lobby door access).  
Type 24 Silent Burglary  
Usually assigned to all sensors or contacts on exterior doors and  
windows where bells and/or sirens are NOT desired.  
Provides an instant alarm, with NO audible indication at any keypad  
or external sounder, if the zone is faulted when the system is armed  
in the Away, Stay, Instant, or Maximum modes.  
A report is sent to the central station.  
Type 77 Keyswitch  
Assign to zone wired to a keyswitch.  
Do not use input type “BR” devices with this zone type.  
Type 81 AAV Monitor Zone  
Assign to zone connected to AAV module.  
Monitors 2-way voice sessions as follows:  
Type 05 Trouble by Day/Alarm by Night  
Assign to a zone that contains a foil-protected door or window  
(such as in a store), or to a zone covering a sensitive area such  
as a stock room, drug supply room, etc.  
Can also be used on a sensor or contact in an area where  
immediate notification of an entry is desired.  
Provides an instant alarm if faulted when armed in the Away,  
Stay, Night-Stay, Instant or Maximum (night) modes.  
During the disarmed state (day), the system will provide a  
latched trouble sounding from the keypad (and a central station  
report, if desired).  
Type 06 24-hr Silent Alarm  
Usually assigned to a zone containing an emergency button.  
Sends a report to the central station but provides no keypad  
display or sounding.  
Type 07 24-hour Audible Alarm  
Assign to a zone that has an emergency button.  
Sends a report to the central station, and provides an alarm  
sound at the keypad, and an audible external alarm.  
Type 08 24-hour Auxiliary Alarm  
Assign to a zone containing an emergency button, or to a zone  
containing monitoring devices such as water or temperature  
sensors.  
Sends a report to the central station and provides an alarm  
sound at the keypad. (No bell output.)  
-
When the zone is faulted, all alarm sounding and dialer reporting  
stops, except for fire alarms, which immediately terminate the  
voice session and cause a fire report to be sent.  
When the zone is restored (session ended), sounding resumes (if  
bell timeout has not expired) and reports that were stopped are  
sent.  
Type 09 Supervised Fire  
-
Provides a fire alarm on short circuit and a trouble condition on  
open circuit. A fire alarm produces a pulsing bell output.  
This zone type is always active and cannot be bypassed.  
Types 90-93 Configurable  
Type 10 Interior w/Delay  
Allows for various custom responses. Options include response to  
entry/exit delays, response opens/shorts, types of alarm/trouble  
sounding, dial delay, and unique Contact ID report codes. Types 92  
and 93 can only be programmed via downloader. UL installations:  
Zone Types 90 -93 may not be used as fire or burglar alarm zones on  
fire or UL burglar alarm installations.  
Provides entry delay (using the programmed entry time), if  
tripped when the panel is armed in the Away mode.  
Entry Delay 1 begins whenever sensors in this zone are  
violated, regardless of whether or not an entry/exit delay zone  
was tripped first.  
Bypassed when the panel is armed in the Stay or Instant  
modes; if armed in Night-Stay mode, zones assigned to zone  
list 05 (night-stay zone list) are not bypassed when system  
armed in Night-Stay mode.  
* The system can still be armed when these zone types are in a  
faulted condition.  
34 –  
 
UL NOTICES  
1. Entry Delay No. 1 and No. 2 (fields 35, 36) cannot be greater than 30 seconds for UL Residential Burglar Alarm  
installations, and entry delay plus dial delay should not exceed 1 minute. For UL Commercial Burglar Alarm  
installations, total entry delay may not exceed 45 seconds.  
2. For UL Commercial Burglar Alarm and UL Residential Burglar Alarm installations with line security, total exit delay time  
must not exceed 60 seconds.  
3. The maximum number of reports per armed period (field 93) must be set to “0” (unlimited) for UL installations.  
4. Periodic testing (see scheduling mode) must be at least every 24 hours.  
5. Alarm Sounder plus Auxiliary Power currents must not exceed 600mA total for UL installations (Aux power 500mA  
max.).  
6. All partitions must be owned and managed by the same person(s).  
7. All partitions must be part of one building at one street address.  
8. If used, the audible alarm device(s) must be placed where it/they can be heard by all partitions.  
9. For UL commercial burglar alarm installations the control unit must be protected from unauthorized access. The  
tamper switch installed to protect the control unit enclosure door is suitable for this purpose.  
10.Remote downloading without an alarm company technician on-site (unattended downloading) is not permissible for UL  
installations.  
11.Auto-disarming is not a UL Listed feature.  
12.As SIA limits for delay of alarm reporting and sounding can exceed UL limits for commercial and residential  
applications, the following UL requirements per UL681 are provided:  
The maximum time that a control unit shall be programmed to delay the transmission of a signal to a remote monitoring  
location, or to delay the energizing of a local alarm sounding device to permit the alarm system user to enter and  
disarm the system, or to arm the system and exit shall not exceed:  
a) 60 seconds for a system with standard line security or encrypted line security,  
b) 120 seconds for a system without standard line security or encrypted line security, or  
c) 120 seconds for a system that does not transmit an alarm signal to a remote monitoring location.  
13. This control is not intended for bank safe and vault applications.  
SIA QUICK REFERENCE GUIDE  
1. 31 Single Alarm Sounding per Zone: If “0” selected, “alarm sounding per zone” will be the same as the “number of  
reports in armed period” set in field 93 (1 if one report, 2 if 2 reports, unlimited for zones in zone list 7).  
2. 34 Exit Delay: Minimum exit delay is 45 seconds.  
3. 35/*36 Entry Delay 1 and 2: Minimum entry delay is 30 seconds.  
4. 37 Audible Exit Warning: Feature always enabled; field does not exist.  
5. 39 Power Up in Previous State: Must be “1,” power up in previous state.  
6. 40 PABX Access Code or Call Waiting Disable: If call waiting is used, call waiting disable option in field *91 must be  
set.  
7. 50 Burglary Dial Delay: Delay must be minimum of 30 seconds.  
8. 59 Exit Error Alarm Report Code: Always enabled.  
9
68 Cancel Report Code: Default is “code enabled.”  
10. 69 Recent Closing Report Code: Always enabled.  
11. 91 Option Selection: Exit Delay option should be enabled. If call waiting is used, Call Waiting Disable must be set to  
“1” (enabled).  
12. 93 No. reports in Armed Period: Must be set for 1 or 2 report pairs.  
13. Cross zone timer programming is set in field 85; cross zone pairs are assigned in zone list 4 using 81 Zone List  
mode.  
14. Duress code is assigned by using the “add a user code” procedure found in the User Guide. Enable Duress code  
reporting by programming zone 92 using 56 Zone Programming mode.  
15. Fire alarm verification is a built-in system feature when a zone is programmed for zone type 16.  
35 –  
 
WORKSHEET FOR 56 ZONE PROGRAMMING  
(FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets]  
Zone Zn Type  
Part.  
Report  
Hardwire  
Type  
Rsp. Time  
Location  
[09]  
[01]  
[03]  
[03]  
[03]  
[03]  
[03]  
[03]  
[1]  
[EOL]  
[1]  
1
2
3
4
5
6
7
8
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[EOL]  
[EOL]  
[EOL]  
[EOL]  
[EOL]  
[EOL]  
[EOL]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
Zone Zn Type  
Part.  
Report  
Input Type  
Loop  
Serial No.  
Location  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
62  
63  
64  
NOTES:  
Zone Type: see chart in  
56 Zone Programming  
Menu mode section.  
Report Code: enabled if  
any digit entered as 1st  
digit;  
Hardwire Type (zns 2-8):  
0 = EOL  
1 = NC  
2 = NO  
3 = ZD  
4 = DB  
Input Type:  
2 = AW (zones 9-48)  
3 = RF (zones 9-48)  
4 = UR (zones 9-48)  
5 = BR (zones 49-64)  
NOTE: Zones 9-16 not  
available if zone  
doubling enabled.  
Response Time:  
0 = 10msec  
1 = 350msec  
2 = 700msec  
3 = 1.2 sec  
Reserved Zones  
91 = addressable device  
report enable/disable  
default zone type =  
[05].  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[1]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
[BR]  
N/A  
92 = Duress report  
enable/disable  
[00] N/A**  
[00] N/A**  
[06] N/A**  
N/A N/A  
N/A N/A  
N/A N/A  
95  
96  
99  
keypad [1] / []  
N/A  
N/A  
keypad [3] / [#]  
keypad [] / [#]  
** Emergency key zones 95, 96, and 99 report the partition of the keypad used to activate the emergency zones.  
36 –  
 
WORKSHEET FOR 57 FUNCTION KEY PROGRAMMING  
Option Function  
A
B
C
D
Comments  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
00  
Paging  
Time Display  
Arm AWAY  
Arm STAY  
Arm NIGHT-STAY  
Step Arming  
Device Activation  
Comm. Test  
Macro Key 1  
Macro Key 2  
Macro Key 3  
Macro Key 4  
Emergency Keys:  
Personal Emergency  
Silent Alarm  
Audible Alarm  
Fire  
Device:  
zone 95  
zone 99  
zone 96  
paging  
n/a  
n/a  
n/a  
n/a  
Emergency Keys: A = paired keys [1] / [] (zone 95); B = paired keys [] / [#] (zone 99); C = paired keys [3] / [#] (zone 96)  
WORKSHEET FOR 79 RELAY/POWERLINE CARRIER (X-10) DEVICE MAPPING  
Applicable only if Relays and/or Powerline Carrier Devices are to be used.  
Must program before using *80.  
OUTPUT TYPE  
Relay  
Output Module Pos  
OUTPUT TYPE (09-16 apply to FA168CPS only)  
X10  
Unit  
No.  
Relay  
Output Module Pos  
X10  
Unit  
No.  
(1-4)  
Description  
(1-4)  
Description  
No.  
01  
02  
03  
04  
05  
06  
07  
08  
Addr.  
No.  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
Addr.  
On-Board Trigger 1  
On-Board Trigger 2  
norm output =  
norm output =  
WORKSHEET FOR 81 ZONE LIST PROGRAMMING  
Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the  
data during the displays and prompts that appear in sequence.  
NOTE: Record desired zone numbers below, noting that a list may include any or all of system's zone numbers.  
List No. Used For…  
Contains These Zones…  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
General Purpose (GP)  
General Purpose  
Chime-by-Zone or GP  
Cross Zones  
(see field *26 for Chime-by-Zone option)  
(see field *85 for Cross Zone Timer option)  
Night-Stay Zones or GP  
Dial Delay Disable or GP  
Unlimited Reports or GP  
General Purpose  
SIA-Compliant Controls: see field *50 for Dial Delay Disable option  
SIA-Compliant Controls: see field *93 for Unlimited Reports option  
Zones activating pager 1  
Zones activating pager 2  
Zones activating pager 3  
Zones activating pager 4  
(FA168CPS)  
(FA168CPS)  
37 –  
 
WORKSHEET FOR 80 OUTPUT FUNCTION PROGRAMMING  
Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you  
enter the data during the displays and prompts that appear in sequence.  
Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes.  
2. For Powerline Carrier devices (plcd), field 27 must be programmed with a House Code.  
3. Tampers of expansion units cannot be used to operate devices.  
Output  
Function  
Number  
(FA168CPS:  
1-48)  
(FA148CP:  
1-24)  
Activation Type and Detail  
Partition  
Number  
Event (for zone list/activated by)  
Action  
0 = off  
1 = close 2 secs  
2 = stay closed FA168CPS: R = relay  
Output  
Number  
Device  
Type  
Activated by Zone List Zone Type Zone No.  
By Zone List  
By Zone No.  
(P)  
0=delete  
1=zn list  
2=zn type  
3=zn no.  
(ZL)  
1-8 = list  
(ZT)  
(see table  
below)  
(ZN)  
00=none  
FA168CPS:  
01-64  
FA148CP:  
01-06, 09-34,  
49-56  
(if using ZT trig)  
0 = any  
0 = restore  
1 = alarm  
2 = fault  
0 = restore  
1 = alrm/flt/trbl  
3 = pulse  
4 = toggle  
1-18  
T = trigger  
X = X10  
1 = partition 1  
2 = partition 2  
3 = common  
5 = duration 1†† FA148CP:  
6 = duration 2†† 1-8, 17, 18  
3 = trouble  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
45  
46  
47  
48  
ZONE TYPE/SYSTEM OPERATION Choices for Zone Types are:  
00 = Not Used  
05 = Trouble Day/Alarm Night 10 = Interior w/Delay  
24 = Silent Burglary  
01 = Entry/Exit#1  
02 = Entry/Exit#2  
03 = Perimeter  
06 = 24 Hr Silent  
07 = 24 Hr Audible  
08 = 24 Hr Aux  
09 = Fire  
12 = Monitor Zone  
77 = Keyswitch  
81 = AAV Monitor Zone  
90-91 = Configurable  
14 = Carbon Monoxide  
16 = Fire w/Verification  
23 = No Alarm Response  
04 = Interior Follower  
Choices for System Operation are:  
20 = Arming–Stay  
21 = Arming–Away  
22 = Disarming (Code + OFF)  
31 = End of Exit Time  
32 = Start of Entry Time  
33 = Any Burglary Alarm  
36 = **At Bell Timeout***  
Note: In normal operation mode:  
38 = Chime  
39 = Any Fire Alarm  
40 = Bypassing  
41 = **AC Power Failure  
42 = **System Battery Low  
43 = Communication Failure  
52 = Kissoff  
58 = Duress  
60 = AAV Trigger  
61 = AVS/GSMV session begin §  
62 = AVS/GSMV session end §  
66 = Function key†  
67 = Bell Failure  
68 = TELCO Line Fault  
78 = Keyswitch red LED†††  
79 = Keyswitch green LED†††  
Code + # + 7 + NN Key Entry starts Device  
Code + # + 8 + NN Key Entry stops Device  
** Use 0 (any) for Partition No. (P) entry.  
*** Or at Disarming, whichever occurs earlier.  
† Use *57 Menu mode to assign the function key.  
†† Duration is set in program field *177.  
††† Device action not used for these choices.  
§ automatically set when appropriate AVS Quick  
Command performed.  
54 = Fire Zone Reset  
38 –  
 
WORKSHEET FOR SCHEDULES  
(installer code + [#] + [6] [4]; master code can only access schedules 01-16 for FA168CPS, 01-04 for FA148CP, and events 00-07 for both  
controls; FA148CP supports up to 8 schedules, FA168CPS supports up to 32 schedules )  
No.  
Event  
(see list below)  
Device No. Group No. Partition  
Start Time/  
Stop Time/  
Days  
Repeat Random  
for “01” events:  
for “02” events: for “04-06” events: Days  
(1-4)  
(yes/no)  
enter 01-18  
enter 1-8 enter 1, 2, or 3  
01  
02  
03  
04  
05  
06  
07  
08  
09  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
Events:  
Master/Installer  
00 = clear event  
01 = device on/off  
02 = user access  
Installer Only  
10 = display custom words 8-10  
11 = periodic test report  
03 = latch key report  
04 = forced STAY arm  
05 = forced AWAY arm  
06 = auto disarm  
07 = display “reminder”  
Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week  
TABLE OF DEVICE ADDRESSES  
This Device  
Uses Address Reports as†† Enabled By…  
RF Receiver  
AUI 1  
AUI 2  
AUI 3  
00  
01  
02  
05  
06  
03  
04  
100  
*56 zone programming: input device type entry  
automatic if AUI enable field *189 enabled for AUI 1  
automatic if AUI enable field *189 enabled for AUI 2  
automatic if AUI enable field *189 enabled for AUI 3 (FA168CPS)  
automatic if AUI enable field *189 enabled for AUI 4 (FA168CPS)  
automatic if communication device enabled in 29 Menu mode  
automatic if phone module access code field *28 enabled  
*56 zone programming: input device type entry, then:  
automatic if zone no. 9-16 entered as AW type or relay assigned  
automatic if zone no. 17-24 entered as AW type or relay assigned  
automatic if zone no. 25-32 entered as AW type or relay assigned  
automatic if zone no. 33-40 entered as AW type or relay assigned  
automatic if zone no. 41-48 entered as AW type or relay assigned  
*79 output device programming: device address prompt:  
entered at device address prompt  
AUI 4  
Communication Device (LRR)  
4286 Voice Module  
103  
104  
Zone Expanders (4219/4229):  
module 1 (for zones 09 - 16)  
module 2 (for zones 17 - 24)  
module 3 (for zones 25 - 32) 09 (FA168CPS)  
module 4 (for zones 33 - 40) 10 (FA168CPS)  
module 5 (for zones 41 - 48) 11 (FA168CPS)  
Relay Modules (4204):  
module 1  
module 2  
module 3  
module 4  
Keypads:  
keypad 1  
keypad 2  
keypad 3  
keypad 4  
keypad 5  
keypad 6  
keypad 7  
keypad 8  
5800TM Module  
07  
08  
107  
108  
109  
110  
111  
12  
13  
112  
113  
114  
115  
entered at device address prompt  
entered at device address prompt  
entered at device address prompt  
data field programming as listed below:  
14 (FA168CPS)  
15 (FA168CPS)  
always enabled, all sounds enabled.  
16  
17  
18  
19  
20  
21  
22  
23  
28  
n/a  
n/a  
n/a  
n/a  
n/a  
n/a  
n/a  
n/a  
n/a  
data field *190  
†† Addressable devices are identified by “1” plus  
data field *191  
the device address when reporting. Enter report  
data field *192  
code for zone 91 to enable addressable device  
reporting (default = reports enabled). See field *19  
for addressable device (ECP) 3-digit/2-digit  
identification keypad display options.  
data field *193  
data field *194  
data field *195  
data field *196  
automatic  
39 –  
 
5800 SERIES TRANSMITTER INPUT LOOP IDENTIFICATION  
All of the transmitters illustrated have one or more unique factory assigned input (loop) ID numbers. Each of the inputs  
requires its own programming zone (e.g., a 5804's four inputs require four programming zones). For information on any  
transmitter not shown, refer to the instructions accompanying that transmitter for details regarding loop numbers, etc.  
UL NOTE: The following transmitters are not intended for use in UL installations: 5802MN, 5802MN2, 5804, 5804BD, 5814,  
5816TEMP, 5819, 5819WHS & BRS, and 5850.  
The 5827BD and 5800TM can be used in UL Listed Residential Burglar installations.  
LOOP 3  
LOOP 4  
YOU MUST  
LOOP 2  
ENROLL  
LOOP 1  
THIS  
BUTTON  
LOOP  
1
LOOP 1  
LOOP 1  
LOOP 1  
LOOP  
1
5800CO  
ENROLL AS "RF"  
5800Micra  
5800SS1  
ENROLL AS "RF"  
5800WAVE  
5801  
5802 MN  
ENROLL AS  
"UR" OR "RF"  
ENROLL AS "RF"  
SET HOUSE ID  
ENROLL AS"RF"  
ENROLL AS  
"UR OR"RF"  
LOOP 3  
LOOP 2  
LOOP 4  
SERIAL #1  
LOOP 4  
LOOP 3  
ON  
YOU MUST  
ENROLL  
THIS  
SERIAL #1  
LOOP 2  
OFF  
ON  
1
LOOP 2  
LOOP 1  
LOOP 1  
YOU MUST  
ENROLL  
THIS  
LOOP 1  
OFF  
2
SERIAL #1  
LOOP 4  
LOOP 1  
BUTTON  
SERIAL #1  
LOOP 1  
3
LOOP  
3
BUTTON  
4
SERIAL #2  
LOOP 3  
••  
••  
LOOP 1  
SERIAL #2  
LOOP 2  
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS  
LOOP 4 = 3 + 4 BUTTONS  
5802 MN2  
ENROLL AS  
"UR" OR "RF"  
5804/5804E  
ENROLL AS "BR"  
5804BD/5804BDV  
ENROLL AS "BR"  
5805-6  
5806/5806W3  
5809  
ENROLL AS "BR"  
5808/5808LST/5808W3  
ENROLL AS "RF"  
SET HOUSE ID  
ENROLL AS "RF"  
LOOP 2  
(REED)  
LOOP 1  
LOOP 2  
(REED)  
(PRIMARY)  
LOOP 1  
(TERMINALS)  
LOOP 1  
LOOP 2  
(REED)  
LOOP 2  
(REED)  
LOOP 2  
(AUX.  
CENTER)  
LOOP 1  
(TERMINALS)  
LOOP 1  
(TERMINALS)  
LOOP 1  
LOOP 3  
(AUX.  
RIGHT)  
ALTERNATE  
POSITION FOR  
LOOP 2  
5815  
ENROLL AS "RF"  
5817  
5814  
5816  
ENROLL AS "RF"  
5816MN  
ENROLL AS "RF"  
5818MNL  
ENROLL AS "RF"  
ENROLL AS "RF"  
ENROLL AS "RF"  
LOOP 2  
(REED)  
LOOP 2  
(REED)  
A
R
M
E
D
R
E
A
DY  
LOOP  
1
LOOP 3  
LOOPS  
1 - 3  
LOOP 1  
(TERMINALS)  
LOOP 1  
(INTERNAL  
SHOCK  
LOOP 1  
(TERMINALS)  
LOOP 3  
(TERMINALS)  
SENSOR  
5819  
ENROLL AS "RF"  
5819S (WHS & BRS)  
ENROLL AS "RF"  
5820/5820L  
ENROLL AS "RF"  
5821  
ENROLL AS "RF"  
5828/5828V  
5853  
SET HOUSE ID  
ENROLL AS "RF"  
SERIAL #1  
LOOP 3  
A
W
SERIAL #1  
LOOP 2  
A
Y
S
T
A
Y
SERIAL #1  
LOOP 4  
1
3
LOOP 1  
(MOTION)  
LOOP 1  
2
LOOP 1  
SERIAL #1  
LOOP 1  
SERIAL #2  
LOOP 3  
4
SERIAL #2  
LOOP 2  
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS  
LOOP 4 = 3 + 4 BUTTONS  
5890/5890PI  
ENROLL AS "RF"  
5897-35  
ENROLL AS "RF"  
5878  
5894PI  
ENROLL AS "RF"  
5800-003-V0  
ENROLL AS "BR"  
2 Corporate Center Drive, Suite 100  
P.O. Box 9040, Melville, NY 11747  
Copyright © 2003 Honeywell International Inc.  
ÊK5305-5PRV5rŠ  
K5305-5PRV5 11/08 Rev. B  
 

Conair Electric Shaver MN252CSC User Manual
Craftsman Lawn Mower 91738836 User Manual
Creative Car Speaker 5200 User Manual
Cub Cadet Lawn Mower 106 User Manual
Cuisinart Frozen Dessert Maker ICE 25 User Manual
Cypress Computer Hardware SL811HS User Manual
Extron electronic Network Card MHR 2 Series User Manual
Extron electronic Stereo Amplifier ASA 204 User Manual
GE Cordless Telephone 15433020 User Manual
GE Monogram Refrigerator ZFGB21HXSS User Manual