MOBILE AIR CONDITIONER
USER’S MANUAL
Read Rules for Safe Operation and Instructions Carefully
SAFETY RULES
1. Do not connect unit to any AC socket in disrepair.
2. Do not use in the following locations:
A: Next to source of fire
B: An area where oil is likely to splash.
C: An area exposed to direct sunlight.
D: An area where water is likely to splash.
E: Near a bath, a shower or a swimming pool.
3. Never insert your fingers or any foreign objects into the air outlet. Take special care to warn children of these
dangers.
4. Always store the unit upright in order to maintain the compressor in a proper condition.
5. Be sure to unplug the unit before cleaning.
6. The heater must not be located immediately below a socket outlet.
7. If the appliance is covered, there is a risk of overheating.
8. If the plug or electrical cord is damaged, it must be replaced by a repair shop appointed by the manufacturer,
because special purpose tools are required.
NOTE: The air-conditioner can be connected only a supply system impedance of no more than 0.4582 ohm. If
unsure, please consult your supply authority for system impedance information.
3
NAME OF PARTS
REAR COVER
FRONT COVER
AIR INLET
OPERATION
PANEL
AIR OUTLET
AIR OUTLET
WATER PUMP
DRAIN HOSE
REMOTE
CONTROLLER
AIR INLET
AIR INLET
POWER CORD
CONTINUOUS
DRAIN HOSE
CASTER
REAR VIEW
SIDE VIEW
FRONT VIEW
Fig.1
ACCESSORIES
QUANTITY
PARTS
PARTS NAME
DUCT ASSEMBLY
1
INSTALLTION PLATE
WATER PUMP DRAIN HOSE
1
Fig.2
Check all the accessories are included in the package and please refer to the installation instructions for their
usage.
4
OPERATION PANEL OF THE AIR CONDITIONER
i.
A model display indicators (with electricity heating):
ly
light
Set
e
e
Fig.3
ii.
A model display indicators (only cooling):
light
Set
Fig.4
5
● B model display indicators :
F
Receiver
Fig.5
DISPLAY:
Locked indicate
Fan speed
Auto mode indicate
Heating mode indicate
mode indicate
Swing indicate
F
Cooling mode indicate
Digital display
Timer indicate
Fig.6
Note: 1.The Auto Cooling Heating Dry mode indicators will not display in the Fan mode.
2.The relevant display light according the set content by remote controller.
3.Air conditioner does not operate normally when set temperature indicator displaies unnormally, please
contact with the distributor for service.
<<Could you remove #2, #3 above? I do not understand what they mean.>>
6
OPERATION OF THE REMOTE CONTROL
Display Screen
ON/OFF Button
For setting display
Press this button to start /
stop air conditioner.
Sleep Button
Temp Adjustment Buttons
Press “▼” to decrease temp.
Press “▲” to increase temp.
For setting sleep
SET TEMP
function.
AUTO
PROGRAM
Mode selection Button
For selecting
Fan speed button
AUTO
COOL
SWEEP
HEAT
DRY
ON/OFF
SLEEP
For selecting indoor fan
speed:
Auto
Medium
AUT
TEMPERATURE
High
Low
Airflow sweep Button
AUH Button
FAN SPEED
FAN SWEEP
TIMER
MODE
AUH
For changing louver
position.
To change the condition of starting
auxiliary electric heater when air
conditioner in HEAT mode.
Timer selection Button
Selecting procedures:
TIME
HOUR
MINUTE
On timer → Off timer→
Program control →Timer
cancelled →On timer
Time setting Button
Press this button to
RESET
set timer or the clock
time.
Minute Button
Press this button to change
the minute setting.
Hour Button
Press this button to
change hour setting.
Reset Button
Reset remote control to
the original status.
Remarks: Temperature can be set between60 ~89
.
7
Remote Controller Display
Operating Mode Selection
Display
AUH Display
It appears when
pressing the AUH
key is add in HEAT
mode.
Timer setting
Display
Signal Emission
Symbol
It appears when
control signal is
emitted.
HEAT
AUTO
COOL
FAN
ON timer
DRY
OFF timer
PROGRAM
Wind Speed Selection
Display
Program
SET TEMP
AUT
PROGRAM
Timer canceled
Auto
AUT
High speed
Time Display
Displays the time of
Medium speed
Low speed
clock
or
timing
ON/OFF.
Air refresh Display
(Not available)
Display
displayed when
temp is displayed.
Sleep Mode Display
Displayed when Pressing “SLEEP”
button the unit will enter into sleeping
operation.
Instructions for the remote controller
z
The remote controller uses two AAA alkaline battrries. Under normal condition, the batteries last for
about 6 months. Please use two new batteries of similar type (pay attention to the poles in installing).
After replacing the batteries, please use a point object (such as pen tip) to press “Reset” button.
The effective control distance of the remote controller is about 8 yards.
z
z
When using the remote controller, please point the signal emitter towards the air conditioner receiver;
There should be no obstacles between the remote controller and the air conditioner.
Do no press two buttons simultaneously on the remote control.
z
z
Do not use wireless equipment (such as mobile phone) near the air conditioner. If interference occurs
because of this, please switch off the air conditioner, pull out power plug, then plug again and switch
on after a while.
z
If direct sunlight is hitting the the receiver on the air conditioner it may not be able to receive the signal
from the remote controller.
z
z
z
Take care not to drop theh remote control and keep from direct sunlight or heat sources.
Keep the remote control dry, if it gets wet use a soft, dry cloth for cleaning.
The batteries must be removed from the remote control before it is scrapped and disposed of safely.
8
OPERATION METHOD
AUTO, HEAT, COOL,FAN and DRY operation
Setting Operation Mode
Auto
Cool
Heat
Dry
Sweep
1
SET TEMP
AUTO
Temp Adjustment Buttons
Press “ ▲ ” “ ▼ ” buttons to set
temp as needed.
2
3
4
Switch On
Press ON/OFF button to start air
conditioner.
ON/OFF
SLEEP
TEMPERATURE
Airflow selection
Press “FAN SWEEP” button to select
airflow direction.
FAN SPEED
FAN SWEEP
MODE
AUH
Setting Fan Speed
Four speeds can be selected:
AUT
5
Auto
High
Medium
Low
Switch Off
Press ON/OFF button to stop air
conditioner.
6
Remarks:
1.When “AUTO” mode is set, the air conditioner will adjust the fan speed and select the COOL or DRY
mode according to the indoor temperature.
2.When “AUTO” mode is set, SLEEP and AUH functions are not available.
3.When “DRY” mode is set, in accordance with the D-value between indoor temperature and set
temperature, the air conditioner will start or stop the cooling operation and fan speed automatically to
decrease room humidity. The fan speed may change to maintain the humidity.
4.When “FAN” mode is set, temperature can’ t be adjusted. Step 2 of Operating precudures is not effective.
Only high, medium and low fan speed can be set; no Auto fan speed.
5.In the cooling-only model,the “AUH” function is not available and there is no AUTO-HEAT mode.
9
Clock Setting
SET TEMP
Press “TIME” button to
SLEEP
ON/OFF
select
will flash.
, clock display
1
2
TEMPERATURE
FAN SPEED
MODE
AUH
Press “HOUR” button to
change the hour display,
each press of HOUR
button will increase or
decrease the time display
by 1 hour; hour display
Press “MINUTE” button
to change the minute
display, (the method as
step 2). The clock
display will flash for 10
seconds after setting, the
FAN SWEEP
TIMER
TIME
HOUR
MINUTE
3
will
continuously
pressing it continuously.
be
changed
when
RESET
remote
controller
displays current time.
On Timer
SET TEMP
Set the clock time as
Clock Setting ,
Press “TIME” button to
1
2
SLEEP
ON/OFF
select ON
, clock
display will flash.
TEMPERATURE
FAN SPEED
MODE
AUH
Press “HOUR” or
“MINUTE” button; set
the time to turn on the
air conditioner on timer.
At this time if user press
“MINUTE” button, it
FAN SWEEP
TIMER
TIME
Press “TIMER”
button to select
HOUR
MINUTE
3
ON
.
RESET
will
increase
or
decrease by 10 minutes.
Note:
1. When on timer function is set, air conditioner will be turned off immediately. It will be turned on at the set
time; symbol “ ON ” will be deleted. If the set time is as same to the current time, air conditioner will be
turned on at this time of next day.
2. Press “ON/OFF” to cancel “On Timer” function, air conditioner will be turned on immediately.
10
Off Timer
SET TEMP
Set the clock time as
Clock Setting ,
SLEEP
ON/OFF
Press “TIME” button to
1
select
OFF, clock
display will flash.
TEMPERATURE
FAN SPEED
MODE
AU
Press “HOUR” or
“MINUTE” button; set
the time to turn on the
air conditioner on
timer. At this time if
user press “MINUTE”
button, it will increase
or decrease by 10
minutes.
FAN SWEEP
TIMER
H
TIM
Press
button to select
“TIMER”
2
E
HOUR
MINUT
E
3
OFF .
RESET
Note:
1. When off timer function is set, air conditioner will be turned on immediately. It will be turned off at the set
time; symbol “ OFF ” will be deleted. If the set time is as same to the current time, the air conditioner
will be turned off at this time of next day.
2. Press “ON/OFF” to cancel “Off Timer” function, air conditioner will be turned off immediately.
Program Control
SET TEMP
Note:
PROGRAM
1. In accordance with the clock
1. Refer to
Clock
time , air conditioner will select
to work in “On Timer” or “Off
Timer” mode automatically.
Setting
to Set the
SLEEP
ON/OFF
clock time.
2. Refer to
On
TEMPERATURE
PROGRAM
PROGRAM
Timer to Set the
1
time to turn on the air
conditioner.
FAN SPEED
MODE
AU
ON
OFF
FAN SWEEP
TIMER
3. Refer to
Off
H
TIM
2. Air conditioner will be turned
on/off at the set time everyday. If
user turns off the air conditioner
by hand before the set time, then
“Off timer” function will be
cancelled; but “On timer”
function is still effective. If user
turns on the air conditioner by
hand before the set time, then
“On timer” function will be
cancelled; but “Off timer”
function is still effective.
Timer to Set the
time to turn off the air
conditioner.
E
HOUR
MINUT
E
RESET
Press
“TIMER”
button to select
2
PROGRAM
KEY-OPERATING INSTRUCTON FOR THE AIR
CONDITIONER
11
Before Starting This Unit
1) Select a suitable location ,make sure you have easy access to an electrical outlet.
2) Install the Flexible Exhaust Hose and the Adjustable Window Slider Kit as depicted in Fig.7
Fig.7a
NOTE: Step 2) is required only while using the cooling mode.
Fig.7
Fig.7a
3) Plug the unit into the grounded electrical outlet.
4) Make sure the water pump drain hose is correctly installed, as Fig.8 .
5) Press the on/off button to turn on the unit.
Fig.8
1. BEFORE USE
Made sure the duct is installed well.
Dehumidifying and Cooling Operations
-
-
-
The operating range for dehumidifying is 60 -89 ,and the operating range for cooling operating is 60
-89 .
If the cooling or dehumidifying operations have been switched off and need switching on again in a short
time, allow approximately three minutes for the cooling or dehumidifying operations to resume.
Make sure the water pump drain hose is correctly connected to the unit.
12
Power supply:
-
Insert the plug of the air conditioner into a standard three prong outlet.
2. COOLING OPERATION
-
-
Connect the power and press the “ ON/OFF ” button.
Press the “ MODE” button several times until the cooling indicator light comes on.
-
-
Press the “ TEMP SETTING” buttons▲or ▼ to select your desired room temperature. (60 -89 )
Press the ″FAN SPEED″ button to choose the fan speed: Auto High Medium Low.
3. DEHUMIDIFYING OPERATION
-
-
Connect the power and press the “ ON/OFF ” button.
Press the “MODE” button several times until the dehumidifying indicator light comes on.
- Press the “TEMP SETTING” buttons▲or ▼ to select your desired room temperature. (60 -89 )
-
-
The fan will often run at a fixed low speed at this setting.
Keep windows and doors closed for the best dehumidifying effect.
4. HEATING OPERATION (not available for cooling-only type air conditioner)
-
-
-
-
-
Connect the power and press the “ ON/OFF ” button.
Press the “MODE” button several times until the heating indicator light comes on.
Press the “TEMP SETTING” button▲or▼to select your desired room temperature. (60 -89 )
Press the “FAN SPEED” button to choose the fan speed: Auto High Medium Low.
The fan will delay to be off for a few minutes when the AUH has been off.
5. FAN OPERATION
-
-
-
Connect the power and press the “ ON/OFF ” button.
Press the “MODE” button several times until the fan indicator light comes on.
Press the “FAN SPEED” button to choose the fan speed: High Medium Low.
6. TIMER OPERATION
Setting the on timer:
-
Press the “TIMER ON” button or “TIMER” button when the air conditioner is off . Press the “TEMP SETTING”
button▲or▼to select the time you need turn on the unit .
-
-
The starting time is adjustable from 01 to 24.
The operation paned window will display “ ON ”or the timer-on indicate light.
Setting the off timer:
-
Press the “TIMER OFF” button when the air conditioner is on. Press the “TEMP SETTING” button▲or▼
to select the time you need turn off the unit.
-
-
The turning off time is adjustable from 01 to 24.
The operation paned window will display “ OFF ”or the timer-off indicate light.
7. WATER PUMP DRAINAGE
-
Connect the water pump drain hose to the unit before operating. When the water level of the internal water
tank reaches a predetermined level, the water pump will be activated and drain the condensed water
outside through the connected drain hose. The maximum delivery lift is 3.0m(10 feet).(Under this
condition, ensure the rubber stopper is attached to continuous drainage plug at the bottom of the unit.
13
This is located on the back-side of the AC.)
8. CONTINUOUS DRAINAGE
-
When you plan to leave this unit unused for a long time or do not want to use the water pump, remove the
rubber stopper from the continuous drainage plug and attach a tube or hose for continuous drainage. All
the water in the water tank will drain once the continuous drainage plug is removed.(Under this condition,
the water pump is not activated.)
NOTE: 1. This type of air conditioner’ s waterproof level is IPX0. Do not use it in the laundry or bathroom.
a)Fuse:RF1-20 5A 250V or F3.15AL250V,rated current:5A or 3.15A.
3. The rules of line must accord with the standard of exporting countries or nations.
4. Seconds after pressing ”UP” and “DOWN” simultaneously, operation panel is locked and the displayer
shows “LOCKED”. All buttons on operation panel are invalid, but the remote controlling signals are valid.
Pressing again”UP” and “DOWN” simultaneously, the operation panel is unlocked and the “LOCKED” on
displayer disappears. Then operation panel comes back to the normal state.
INSTALLATION
1. IMPORTANT:
Install the portable air conditioner in a flat and spacious location where the air inlets or outlets will not be
blocked. A minimum clearance of 12 inches from a wall or other obstacles should be kept(as Fig.9 show). The
appliance shall not be used in the laundry. The plug shall be accessible after the appliance is positioned.
Wiring shall be done according to National rules.
Fig.9
2. DUCT MOUNT INSTRUCTIONS:
14
Fig.10
A) TEMPORARY
1.
Attach one end of the duct to the exhaust air outlet of the mobile air conditioner, first fit the left
side of the duct on the exhaust air panel, then the right side duct. Push it downwards, be sure to
fix thoroughly.(See the fig.10 )
2.
Put the end of duct to a nearby window.
Window Kit Installation
Your window kit has been designed to fit most standard “Vertical” ,and “horizontal” window applications ,
However, it may be necessary for you to improvise/modify some aspects of the installation procedures for certain
types of window .
Please refer to Fig.11&Fig.11a for minimum and maximum window openings.
Fig.11
Fig.11a
Drain Tank Safety Feature
This unit is equipped with a internal water tank, two full-safe switch mechanisms, one is used to control the
water pump drainage, the other is used to monitor the water level inside the internal water tank. When the water
level reaches a predetermined altitude, the digital display shows “E5” and the water full indicator light
illuminates. Cut off the power and move the unit outside carefully, remove the rubber blockage from the back
drainage hole and drain the water off. The unit will continue operating properly.
15
MAINTENANCE
IMPORTANT:
1) BE SURE TO UNPLUG THE UNIT BEFORE CLEANING.
2) DO NOT USE GASOLINE, THINNER OR OTHER CHEMICALS TO CLEAN THE UNIT.
3) DO NOT WASH THE UNIT DIRECTLY UNDER A TAP OR USING A HOSE.
4) IF THE POWER CORD IS DAMAGED, IT SHOULD BE REPAIRED BY MANUFACTURE OR ITSAGENCY.
Fig.12
1. AIR FILTER
-
-
Clean the air filter at least once every two weeks to prevent inferior fan operation from dust build-up.
Removal
Pull out the filter cover and remove the air filter from the filter cover.
-
cleaning
Wash the air filter by immersing it gently in warm water (about 104 )with a neutral detergent. Rinse the
filter and dry it in a shady place.
- Mounting
Attach the air filter to the filter cover using the attachment hooks on the inner surface of the cover. Put the
filter cover back to the unit.
2. UNIT ENCLOSURE
-
Use a lint-free cloth soaked with neutral detergent to clean the unit enclosure. Finished by a dry clean
cloth.
TROUBLE SHOOTING
16
SUGGESTED
REMEDIES
PROBLEM
POSSIBLE CAUSES
- Water full indicator blinks, Dump the water in the water
1. UNIT DOES NOT START
WHEN PRESSING ON/OFF
BUTTON
water tank is full.
tank.
- Room temperature is higher Reset the temperature.
than the set temperature.
(Heating mode)
- Room temperature is lower Reset the temperature.
than the set temperature.
(Cooling mode).
- LCDI plug was tripped.
Press the reset button on the
LCDI plug. Press On/Off
button on the air conditioner.
- The windows or doors in the Make sure all the windows and
room are not closed. doors are closed.
- There are heat sources inside Remove the heat sources if
the room. possible.
- Exhaust air duct is not Connect the duct and make
2. NOT COOL ENOUGH
connected or blocked.
sure it can function properly.
For best performance keep as
short and straight as possible.
- Temperature setting is too Decrease the set temperature.
high.
Air filter is blocked by dust.
Clean the air filter.
- AC stopped cooling after Turn unit off for 3 minutes,
checking each item above.
press the reset button on the
LCDI plug, turn the AC back
on and select a temperature
lower
temperature.
- The ground is not level or not Place the unit on a flat, level
flat enough. ground if possible.
than
the
room
3. NOISY OR VIBRATION
4. GURGLING SOUND
The sound comes from the It is normal.
flowing of the refrigerant
inside the air-conditioner.
NOTE: When the pipe sensor or the room sensor is error, the digital display shows “E1”or“E2” accordingly.