Bryant 561C User Manual

561C (60 Hz)  
ELECTRIC  
AIR CONDITIONER  
Sizes 018 thru 060  
Model 561C Energy-Efficient Air Conditioners incorporate inno-  
vative technology to provide reliable summer cooling perfor-  
mance. Built into these units are the features most desired by  
homeowners today including SEER ratings of up to 11.5 when  
used with components designated by manufacturer. All models  
are listed with UL, c-UL, ARI, CEC, and CSA-EEV.  
AVAILABLE OPTIONS  
UNIT DESIGN—Copper tube, enhanced sine wave aluminum  
fin coil is designed for optimum heat transfer. Vertical air dis-  
charge carries sound and hot condenser air up and away from  
adjacent patio areas and foliage. Heat pump-style base pan for  
easy removal of water, dirt, and leaves.  
ELECTRICAL RANGE—All units are offered in 208–230v sin-  
gle phase. Three-phase units are available from 030 through  
060 sizes in 208/230v and from 036 through 060 sizes in 460v.  
WIDE RANGE OF SIZES—The 561C is available in 7 nominal  
sizes from 018 through 060 to meet the needs of residential and  
light commercial applications.  
WEATHER-PROTECTIVE CABINET—The steel panels are  
protected with a galvanized coating then covered with a layer of  
zinc phosphate. A modified polyester powder coating is then  
applied and baked on, providing each unit with a hard, smooth  
finish that will last for many years.  
All screws on cabinet exterior are coated for a long-lasting, rust-  
resistant, quality appearance.  
TOTALLY ENCLOSED FAN MOTOR—Means greater reliability  
under rain conditions and dependable performance for many  
years. The permanent-split-capacitor-type motor was designed  
for optimum efficiency. Then, under extreme conditions, the  
motor was tested and qualified to help ensure the greatest reli-  
ability.  
APPLICATION VERSATILITY—The unit can be combined with  
a wide variety of evaporator coils and blower packages to pro-  
vide quiet, dependable comfort. Unit can be installed on a roof  
or at ground level on a slab.  
EXTERNAL SERVICE VALVES—The service valves are brass,  
front seating type. The 561C has sweat field connections.  
Valves are externally located so refrigerant tube connections  
can be made quickly and easily. Each valve has a service port  
for ease of checking operating refrigerant pressures.  
EASY SERVICEABILITY—One access panel provides access  
to electrical controls and compressor. Removal of wire dome  
gives access to fan motor and removal of the top gives access  
to the coil.  
COMPRESSOR PROTECTION—Each compressor is pro-  
tected with internal temperature- and current-sensitive over-  
loads. An internal pressure relief valve provides high-pressure  
protection to the refrigerant system.  
LIMITED WARRANTY—Standard 1-year warranty on parts,  
with an additional 4-year warranty on compressor.  
Form No. PDS 561C.18.6  
CHECK-FLO-RATER® PISTON CHART  
PISTON*  
IDENTIFICATION NO.  
UNIT SIZE  
018-A, D  
024-A, D  
030-A, D  
036-A, D, E  
036-B  
042-A, C  
042-B  
048-A, C  
048-B  
52  
57  
67  
73  
70  
76  
82  
88  
84  
93  
90  
060-A, E  
060-B  
* Piston listed is for any approved coil non-capillary tube combination.  
Piston is shipped with outdoor unit and must be installed in an approved  
indoor coil.  
RECOMMENDED TUBE DIAMETERS  
Liquid Tube Diameter (In.)  
Vapor Tube Diameter (In.)  
UNIT  
SIZE  
0 to 50 Ft  
Tube Length  
0 to 50 Ft  
Tube Length  
Long-Line Applications*  
(Maximum Diameter)  
Long-Line Applications*  
018, 024  
030, 036  
042, 048  
060  
5/8  
3/4  
7/8  
3/4  
7/8  
1-1/8  
1-1/8  
3/8  
3/8  
1-1/8  
* For tube sets between 50 and 175 ft, consult Residential Split System Long-Line Application Guideline.  
SOUND POWER (dBA)  
OCTAVE BAND CENTER FREQUENCY (Hz)  
UNIT  
SIZE  
SOUND  
LEVEL (dBA)  
125  
55.5  
57.5  
59.5  
55.5  
55.0  
54.0  
57.0  
55.0  
56.0  
56.5  
58.0  
59.0  
57.0  
58.5  
57.0  
61.0  
57.5  
57.5  
58.0  
250  
64.0  
64.0  
65.0  
63.0  
62.5  
68.5  
64.5  
64.0  
64.5  
70.0  
69.5  
66.5  
69.0  
72.5  
67.5  
69.0  
68.0  
69.5  
64.0  
500  
68.5  
69.5  
69.5  
68.0  
73.5  
72.5  
73.0  
73.0  
69.0  
73.5  
73.0  
68.5  
72.5  
74.0  
72.0  
70.0  
69.0  
75.0  
70.0  
1000  
73.0  
72.0  
74.0  
71.0  
74.0  
73.0  
74.0  
74.5  
75.5  
75.5  
71.5  
75.5  
71.5  
77.0  
73.0  
74.0  
72.5  
76.0  
74.0  
2000  
71.0  
71.5  
73.0  
70.5  
71.0  
70.5  
72.0  
72.0  
75.0  
74.5  
69.5  
71.5  
69.5  
72.5  
68.5  
75.5  
70.5  
70.5  
72.0  
4000  
66.5  
68.0  
70.0  
67.5  
67.5  
67.0  
73.0  
68.5  
72.0  
71.0  
68.0  
73.0  
68.0  
70.0  
67.0  
74.5  
71.0  
69.0  
71.0  
8000  
018-A  
018-D  
024-A  
024-D  
030-A  
030-D  
036-A  
036-B  
036-D  
036-E  
042-A  
042-B  
042-C  
048-A  
048-B  
048-C  
060-A  
060-B  
060-E  
80  
80  
80  
82  
80  
80  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
82  
59.5  
60.0  
62.0  
58.5  
59.5  
61.5  
65.5  
64.0  
69.5  
65.0  
63.5  
65.5  
64.0  
65.0  
60.5  
66.5  
70.0  
63.0  
67.0  
P
CERTIFICATION APPLIES ONLY  
REGISTERED QUALITY SYSTEM  
WHEN THE COMPLETE SYSTEM  
IS LISTED WITH ARI.  
—3—  
SPECIFICATIONS  
UNIT SIZE-SERIES  
561C018-A, D  
561C024-A, D  
561C030-A, D  
561C030-A  
Operating Weight (Lb)  
113/115  
115/117  
124/133  
124  
ELECTRICAL  
Unit Volts—Hertz—Phase  
Operating Voltage Range*  
Compressor— Rated Load Amps  
Locked Rotor Amps  
208-230—60—1  
197—253  
10.7/11.6  
56.0/60.0  
1.0  
208/230—60—3  
187—253  
9.4  
9.6/9.0  
49.0/48.0  
0.8  
14.2/14.8  
75.0/73.0  
0.8  
68.0  
Condenser Fan Motor—Full Load Amps  
Min Unit Ampacity for Wire Sizing  
Min Wire Size (60°C Copper) AWG†  
Min Wire Size (75°C Copper) AWG†  
Max Wire Length (60°C) (Ft)‡  
Max Wire Length (75°C) (Ft)‡  
Max Branch Circuit Fuse Size**  
COMPRESSOR & REFRIGERANT  
Compressor— Manufacturer  
Type  
0.8  
12.8/12.1  
14.4/15.5  
18.6/19.3  
12.6  
14  
14  
61/65  
58/61  
20/15  
50/49  
50/47  
20  
40  
40/38  
25  
70  
65  
15  
Copeland/Bristol  
Copeland  
Reciprocating  
Internal Line Break  
Temperature and Current Protection  
Refrigerant—Type and Amount @ 15 Ft  
CONDENSER COIL & FAN  
Coil Face Area (Sq Ft)  
R-22 and 3.25/3.30  
5.6  
R-22 and 3.76/3.65  
R-22 and 4.19/4.25  
R-22 and 4.19  
6.2  
7.4  
25—1—1/  
22—1—1  
25—1—1/  
22—1—1  
25—1—1/  
25—1—1  
Fins Per In.—Rows—Circuit  
25—1—2  
Fan Motor—PSC Type, HP and RPM  
Volts—Hertz—Phase  
Condenser Airflow (CFM)  
OPTIONAL EQUIPMENT  
Coastal Filter  
1/8 and 1500  
1/6 and 1500  
1/10 and 1125  
1/10 and 1125  
208/230—60—1  
1400/1500  
1550/1600  
2000  
1700  
KAACF0601SML  
KAACF0401MED  
P251-0083 (RCD)  
Time-Delay Relay  
KAATD0101TDR  
KSACY0101AAA  
Cycle Protector  
Low-Ambient Controller  
Crankcase Heater  
N/A  
KAACH1001AAA  
Inlet Grille Kit  
KSABG0105CMC  
KSAHS0901AAA  
KSABG0205CMC  
KSABG0604CSM  
Start Assist—Capacitor/Relay Type††  
Start Assist—PTC Type  
KSAHS1001AAA/KSAHS0901AAA/KSAHS0901AAA  
KAACS0201PTC  
N/A  
N/A  
N/A / KSASH1301TEC/  
Sound Hood  
N/A  
N/A / KSASH1301TEC  
KSASH2001BRL  
TXV (RPB)  
KAATX0201RPB  
KAATX0301RPB  
KSATX0601HSO  
KAATX0401RPB  
TXV (Hard Shutoff)††  
Low-Pressure Switch  
High-Pressure Switch  
Filter Drier  
KAALP0101LPS  
KSAHI0101HPS  
P502-8083S (RCD)  
KAAFT0101AAA  
KAALS0101LLS  
KAAWS0101AAA  
Evaporator Freeze Thermostat‡‡  
Liquid-Line Solenoid Valve††  
Winter Start Control‡‡  
MotorMaster® Control***  
Ball Bearing Fan Motor  
N/A  
N/A  
32LT660004 (RCD)  
HC34GE231 (RCD)  
Thermostat, Auto Changeover,  
Non-Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBNAC01-B  
TSTATBBPAC01-B  
TSTATBBBAC01-B  
Thermostat, Auto Changeover,  
7-Day Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
Builder’s Thermostat, Manual Changeover,  
Non-Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
Thermidistat Control, Programmable/  
Non-Programmable Thermostat with  
Humidity Control  
TSTATBBPRH01-B  
TSTATXXSEN01-B  
Outdoor Air Temperature Sensor  
Backplate for Non-Programmable  
Thermostat  
TSTATXXNBP01  
TSTATXXPBP01  
TSTATXXBBP01  
TSTATXXCNV10  
Backplate for Programmable Thermostat  
Backplate for Builder’s Thermostat  
Thermostat Conversion Kit (4 to 5 wire)  
See notes on page 7.  
—4—  
SPECIFICATIONS Continued  
561C036-A, B, E  
561C036-B, D  
561C036-B  
561C042-A, B  
561C042-B, C  
561C042-B  
UNIT SIZE-SERIES  
Operating Weight (Lb)  
129/138/138  
129/133  
133  
138/142  
142  
ELECTRICAL  
Unit Volts—Hertz—Phase  
208-230—60—1 208/230—60—3  
460—60—3  
208-230—60—1 208/230—60—3  
460—60—3  
Operating Voltage Range*  
197—253  
16.7/14.8/16.0  
95.0/86.0/81.0  
1.4  
187—253  
10.0/10.6  
75.0/64.5  
1.4  
414—506  
5.1  
197—253  
20.5/19.7  
115.0/102.0  
1.4  
187—253  
13.6/12.4  
91.0/90.0  
1.4  
414—506  
6.2  
Compressor— Rated Load Amps  
Locked Rotor Amps  
33.0  
0.8  
42.0  
0.8  
Condenser Fan Motor—Full Load Amps  
Min Unit Ampacity for Wire Sizing  
Min Wire Size (60°C Copper) AWG†  
Min Wire Size (75°C Copper) AWG†  
Max Wire Length (60°C) (Ft)‡  
Max Wire Length (75°C) (Ft)‡  
Max Branch Circuit Fuse Size**  
COMPRESSOR & REFRIGERANT  
22.3/19.9/21.4  
12  
13.9/14.7  
14  
7.2  
27.0/26.0  
10  
18.4/16.9  
14  
8.6  
14  
14  
12  
14  
14  
10  
14  
14  
55/55/58  
50/55/55  
30  
65/60  
62/55  
20  
250  
238  
15  
70/75  
70  
45/50  
45/50  
25  
210  
200  
15  
40  
Millennium/  
Copeland/Bristol  
Copeland/  
Millennium  
Millennium/  
Copeland  
Copeland/  
Millennium  
Compressor— Manufacturer  
Copeland  
Copeland  
Scroll/  
Reciprocating/  
Reciprocating  
Reciprocating/  
Scroll  
Scroll/  
Reciprocating  
Reciprocating/  
Scroll  
Type  
Reciprocating  
Reciprocating  
Temperature and Current Protection  
Internal Line Break  
R-22 and 5.00/ R-22 and 5.13/  
R-22 and 4.63/ R-22 and 5.00/  
R-22 and 5.13  
25—1—3  
Refrigerant—Type and Amount @ 15 Ft  
CONDENSER COIL & FAN  
Coil Face Area (Sq Ft)  
5.00/4.60  
4.63  
R-22 and 5.00  
5.13  
5.00  
9.1  
10.7  
20—1—2/  
25—1—2/  
25—1—2  
25—1—2/  
20—1—2  
22—1—3/  
25—1—3  
25—1—3/  
22—1—3  
Fins Per In.—Rows—Circuit  
25—1—2  
1/5 and 1125/  
1100/1125  
Fan Motor—PSC Type, HP and RPM  
Volts—Hertz—Phase  
1/5 and 1125  
1/4 and 1125  
460—60—1  
1/5 and 1125  
208/230—60—1  
3400  
1/4 and 1125  
460—60—1  
208/230—60—1  
2500  
Condenser Airflow (CFM)  
OPTIONAL EQUIPMENT  
Coastal Filter  
KAACF0401MED  
KAATD0101TDR  
Standard/  
KSACY0101AAA  
P251-0083 (RCD)  
Time-Delay Relay  
Standard/  
KSACY0101AAA/  
KSACY0101AAA  
Cycle Protector  
KSACY0101AAA  
KSACY0101AAA  
Low-Ambient Controller  
Crankcase Heater  
KAACH1201AAA /  
KAACH1001AAA/  
KAACH1001AAA  
KAACH1201AAA/  
KAACH1001AAA  
KAACH1101AAA KAACH1201AAA/KAACH1001AAA KAACH1101AAA  
Inlet Grille Kit  
KSABG0804CSM  
KSABG1004CSM  
KSAHS1501AAA/  
KSAHS1501AAA/  
KSAHS1001AAA/  
KSAHS1101AAA  
Start Assist—Capacitor/Relay Type††  
Start Assist—PTC Type  
Sound Hood  
N/A  
N/A  
N/A  
N/A  
KSAHS1301AAA  
KAACS0201PTC  
KAACS0201PTC  
KSASH1901CYL/  
KSASH1201COP/  
KSASH2001BRL  
KSASH1901CYL/  
N/A  
N/A  
KSASH1901CYL /KSASH1201COP KSASH1201COP  
TXV (RPB)  
KAATX0501RPB  
TXV (Hard Shutoff)††  
Low-Pressure Switch  
High-Pressure Switch  
Filter Drier  
KSATX0601HSO  
KAALP0101LPS  
KSAHI0101HPS  
P502-8083S (RCD)  
P502-8163S (RCD)  
Evaporator Freeze Thermostat‡‡  
Liquid-Line Solenoid Valve††  
Winter Start Control‡‡  
MotorMaster® Control***  
Ball Bearing Fan Motor  
KAAFT0101AAA  
KAALS0101LLS  
KAAWS0101AAA  
32LT660004 (RCD)  
HC40GE230 (RCD)  
32LT660005 (RCD)  
HC40GE461 (RCD)  
32LT660004 (RCD)  
HC40GE230 (RCD)  
32LT660005 (RCD)  
HC40GE461 (RCD)  
Thermostat, Auto Changeover,  
Non-Programmable, °F/°C, 1-Stage Heat,  
1-Stage Cool  
TSTATBBNAC01-B  
Thermostat, Auto Changeover,  
7-Day Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBPAC01-B  
Builder’s Thermostat, Manual Changeover,  
Non-Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBBAC01-B  
TSTATXXSEN01-B  
TSTATXXNBP01  
TSTATXXPBP01  
TSTATXXBBP01  
TSTATXXCNV10  
Outdoor Air Temperature Sensor  
Backplate for Non-Programmable Thermostat  
Backplate for Programmable Thermostat  
Backplate for Builder’s Thermostat  
Thermostat Conversion Kit (4 to 5 wire)  
See notes on page 7.  
—5—  
SPECIFICATIONS Continued  
UNIT SIZE-SERIES  
561C048-A, B  
561C048-B, C  
192/198  
561C060-A, B  
561C060-B, E  
233/218  
Operating Weight (Lb)  
ELECTRICAL  
Unit Volts—Hertz—Phase  
208-230—60—1 208/230—60—3  
460—60—3  
414—506  
7.4/7.1  
49.5/52.5  
0.8  
208-230—60—1 208/230—60—3  
460—60—3  
414—506  
9.0/8.0  
62.0/66.5  
0.8  
Operating Voltage Range*  
197—253  
24.4/23.7  
140.0/129.0  
1.4  
187—253  
13.5/14.1  
120.0/105.0  
1.4  
197—253  
187—253  
18.3/16.0  
137.0/125.0  
1.4  
Compressor— Rated Load Amps  
Locked Rotor Amps  
28.9/28.8  
165.0/169.0  
Condenser Fan Motor—Full Load Amps  
Min Unit Ampacity for Wire Sizing  
Min Wire Size (60°C Copper) AWG†  
Min Wire Size (75°C Copper) AWG†  
Max Wire Length (60°C) (Ft)‡  
Max Wire Length (75°C) (Ft)‡  
Max Branch Circuit Fuse Size**  
COMPRESSOR & REFRIGERANT  
1.4  
31.9/31.0  
8
18.3/19.0  
14  
10.1/9.7  
14  
37.5/37.4  
24.3/21.4  
12  
12.1/10.8  
14  
8
10  
14  
14  
8
12  
14  
95/100  
55/60  
45/48  
185/182  
175/173  
15  
80  
75  
60  
58/68  
150/165  
142/157  
15  
45/46  
55/65  
50  
25  
35/30  
Millennium/  
Copeland  
Copeland/  
Millennium  
Millennium/  
Copeland  
Copeland/  
Millennium  
Compressor—Manufacturer  
Type  
Scroll  
Scroll  
Scroll  
Scroll  
Temperature and Current Protection  
Refrigerant—Type and Amount @ 15 Ft  
CONDENSER COIL & FAN  
Coil Face Area (Sq Ft)  
Internal Line Break  
R-22 and 6.63/6.38  
R-22 and 9.89/8.46  
14.8  
19.8/16.1  
25—1—4  
Fins Per In.—Rows—Circuits  
Fan Motor—PSC Type, HP and RPM  
Volts—Hertz—Phase  
22—1—3/17—1—3  
1/4 and 1125  
460—60—1  
208/230—60—1  
208/230—60—1  
460—60—1  
Condenser Airflow (CFM)  
OPTIONAL EQUIPMENT  
Coastal Filter  
3400  
KAACF0501LRG  
KAATD0101TDR  
Time-Delay Relay  
Standard/  
KSACY0101AAA  
Standard/  
KSACY0101AAA  
P251-0083 (RCD)  
KAACH1301AAA  
Cycle Protector  
KSACY0101AAA  
KSACY0101AAA  
Low-Ambient Controller  
Crankcase Heater  
KAACH1201AAA  
KAACH1201AAA  
KAACH1301AAA  
KSABG2104CMD  
Inlet Grille Kit  
K5ABG1704CMD  
KSAHS1601AAA  
KAACS0201PTC  
KSABG1804CMD  
KSAHS1601AAA  
KAACS0201PTC  
Start Assist—Capacitor/Relay Type††  
Start Assist—PTC Type  
Sound Hood  
N/A  
N/A  
N/A  
N/A  
KSASH2001CYL / KSASH2101COP  
TXV Kit (RPB)  
KAATX0601RPB  
KAATX0701RPB  
TXV (Hard Shutoff)††  
Low-Pressure Switch  
High-Pressure Switch  
Filter Drier  
KSATX0701HSO  
KAALP0101LPS  
KSAHI0101HPS  
P502-8163S (RCD)  
KAAFT0101AAA  
KAALS0101LLS  
KAAWS0101AAA  
Evaporator Freeze Thermostat‡‡  
Liquid-Line Solenoid Valve††  
Winter Start Control‡‡  
MotorMaster® Control***  
Ball Bearing Fan Motor  
32LT660004 (RCD)  
HC40GE230 (RCD)  
32LT660005 (RCD)  
HC40GE461 (RCD)  
32LT660004 (RCD)  
HC40GE230 (RCD)  
32LT660005 (RCD)  
HC40GE461 (RCD)  
Thermostat, Auto Changeover,  
Non-Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBNAC01-B  
Thermostat, Auto Changeover,  
7-Day Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBPAC01-B  
Builder’s Thermostat, Manual Changeover,  
Non-Programmable, °F/°C,  
1-Stage Heat, 1-Stage Cool  
TSTATBBBAC01-B  
TSTATXXSEN01-B  
TSTATXXNBP01  
TSTATXXPBP01  
TSTATXXBBP01  
TSTATXXCNV10  
Outdoor Air Temperature Sensor  
Backplate for Non-Programmable Thermostat  
Backplate for Programmable Thermostat  
Backplate for Builder’s Thermostat  
Thermostat Conversion Kit (4 to 5 wire)  
See notes on page 7.  
—6—  
* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.  
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).  
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26.  
If other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger than  
10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).  
‡ Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.  
** Time-delay fuse or circuit breaker.  
†† Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 036 and 042, Series A; 048 and 060, Series A/B  
single phase; and all 3-phase units). Do not use hard shutoff TXV with liquid solenoid valve.  
‡‡ Use with low-ambient controller.  
*** Fan motor with ball bearings required.  
N/A—Not Applicable  
NOTES: 1. All motors/compressors contain internal overload protection.  
2. Copper wire must be used from service disconnect to unit.  
3. Control circuit is 24v on all units and requires external power source.  
ACCESSORY USAGE GUIDELINE  
REQUIRED FOR  
LOW-AMBIENT  
APPLICATIONS  
(Below 55°F)  
REQUIRED FOR  
LONG-LINE  
APPLICATIONS*  
(Over 50 Ft)  
REQUIRED FOR  
SEA COAST  
APPLICATIONS  
(Within 2 Miles)  
ACCESSORY  
Crankcase Heater  
Yes  
Yes  
Yes†  
No  
Yes  
No  
No  
No  
No  
No  
No  
No  
Evaporator Freeze Thermostat  
Winter Start Control  
Accumulator  
Compressor Start Assist  
Capacitor and Relay  
Yes  
Yes  
Yes  
No  
No  
No  
Low Ambient Controller  
or  
MotorMaster® Control  
Wind Baffle  
Coastal Filter  
Support Feet  
See Low-Ambient Instructions  
No  
No  
No  
No  
Yes  
No  
Recommended  
Recommended  
Liquid-Line Solenoid Valve  
See Long-Line  
Application  
Guideline  
or  
No  
No  
No  
Hard Shutoff TXV  
Ball Bearing Fan Motor  
Yes  
No  
*
For tubing line sets between 50 and 175 ft, refer to Residential’s Split Systems Long-Line Application Guidelines.  
Only when low-pressure switch is used.  
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)  
1. Ball Bearing Fan Motor  
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.  
SUGGESTED USE: Required on all units where Low-Ambient Controller (full modulation feature) or MotorMaster® Control has been added.  
2. Coastal Filter  
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.  
SUGGESTED USE: In geographic areas where salt damage could occur.  
3. Compressor Start Assist—Capacitor/Relay Type  
Start capacitor and start relay which gives ‘‘hard’’ boost to compressor motor at each start-up.  
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft.  
Installations where outdoor design temperature exceeds 105°F (40.6°C).  
Replacement installations with hard shutoff expansion valve on indoor coil.  
Installations where Liquid-Line Solenoid Valve has been added.  
4. Compressor Start Assist—PTC Type  
Solid-state electrical device which gives a ‘‘soft’’ boost to compressor motor at each start-up.  
SUGGESTED USE: Installations with marginal power supply.  
Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil.  
5. Crankcase Heater  
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication  
on restart and minimizes chance of refrigerant slugging. May or may not include a thermostat control.  
SUGGESTED USE: When interconnecting tube length exceeds 50 ft.  
When unit will be operated below 55°F (12.8°C) outdoor air temperature. (Use with Low-Ambient Controller.)  
All commercial installations.  
6. Cycle Protector  
Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has  
been interrupted for any reason, including normal room thermostat cycling.  
SUGGESTED USE: Installations in areas where power interruptions are frequent.  
Where user is likely to ‘‘play’’ with the room thermostat.  
All commercial installations.  
Installations where interconnecting tube length exceeds 50 ft.  
High-rise applications.  
7. Evaporator Freeze Thermostat  
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.  
SUGGESTED USE: All units where Winter Start Control has been added.  
8. Filter Drier  
A device for removing contaminants from refrigerant circulating in an air conditioner: 1-direction flow.  
SUGGESTED USE: All split-system units.  
—7—  
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued  
9. High-Pressure Switch  
Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 400 ± 10  
psig and resets at 298 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor recycling,  
Cycle Protector can be used with this switch.  
SUGGESTED USE: Installations exposed to very ‘‘dirty’’ outdoor air.  
Installations where condenser inlet air temperature exceeds 125°F (51.7°C).  
10. Inlet Grille Kit  
A field-installed enhanced inlet grille to replace the standard inlet grille on residential air conditioners and heat pumps.  
SUGGESTED USE: For greater protection against inclement weather, incidental damage, and vandalism.  
11. Liquid-Line Solenoid Valve (LSV)  
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts  
refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.  
Note: Compressor Start Assist–Capacitor/Relay Type must also be used. Do not use with hard shutoff TXV.  
SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.  
In certain long-line-applications. Refer to Long-Line Application Guideline.  
12. Low-Ambient Controller  
Head-pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. It is designed to cycle  
the outdoor fan motor in order to maintain condensing temperature within normal operating limits (approximately 100°F high and 60°F low).  
The control will maintain working head pressure at low-ambient temperatures down to 0°F when properly installed.  
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).  
13. Low-Pressure Switch  
Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27  
psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Provides protection against compressor damage due to loss of refrigerant charge. To  
prevent rapid compressor recycling, Cycle Protector can be used with this switch.  
SUGGESTED USE: Where indoor coil is exposed to ‘‘dirty’’ air.  
All commercial installations.  
14. MotorMaster® Control  
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing  
temperature during operation in cooling mode only. For outdoor temperatures down to –20°F, it maintains condensing temperature at 100°F ± 10°F.  
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F.  
All commercial installations.  
15. Outdoor Air Temperature Sensor  
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat  
SUGGESTED USE: All corporate programmable thermostats.  
16. Sound Hood  
Wraparound sound attenuation cover for the compressor. Reduces unit sound level by about 2 dBA.  
SUGGESTED USE: Unit installed closer than 15 ft to quiet areas—bedrooms, etc.  
Unit installed between 2 houses less than 10 ft apart.  
17. Thermostatic Expansion Valve (TXV)  
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the  
evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB valves are available. Do not use hard shutoff TXV  
with Liquid-Line Solenoid Valve.  
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.  
Required for use on all zoning systems.  
18. Time-Delay Relay  
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.  
SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.  
Required for use on all zoning systems.  
19. Winter Start Control  
An SPST delay relay which bypasses the low-pressure switch for approximately 3 minutes to permit start-up for cooling operation under low-load  
conditions.  
SUGGESTED USE: All air conditioners where Low-Ambient Controller has been added.  
—8—  
COMBINATION RATINGS  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
BRYANT GAS  
FURNACE OR  
ACCESSORY  
TDR†  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
TOT. CAP.  
BTUH  
STANDARD  
RATING  
ACCESSORY  
TXV‡  
EERA  
CC5A/CD5AA018*  
CC5A/CD5AA024  
CC5A/CD5AW024  
CE3AA024  
17,200  
17,600  
17,600  
17,800  
17,800  
17,600  
17,200  
17,600  
17,600  
16,800  
17,600  
17,600  
17,200  
17,600  
17,500  
17,500  
17,600  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
TDR  
10.00  
10.50  
10.50  
10.50  
10.50  
10.50  
10.00  
10.50  
10.50  
10.00  
10.50  
10.50  
10.50  
10.50  
10.50  
10.00  
10.50  
10.50  
10.00  
10.50  
9.20  
9.45  
9.45  
9.50  
9.50  
9.55  
9.35  
9.55  
9.55  
9.25  
9.60  
9.60  
9.55  
9.55  
9.35  
10.70  
10.80  
10.00  
10.00  
10.00  
10.00  
10.00  
CF5AA024  
CK3BA024  
CK5A/CK5BA018  
CK5A/CK5BA024  
CK5A/CK5BW024  
F(A,B)4AN(F,C)018  
F(A,B)4AN(F,C)024  
FC4BNF024  
10.00  
10.00  
10.00  
10.50  
10.50  
10.50  
10.50  
TDR  
TDR&TXV  
TDR  
TDR  
NONE  
TDR&TXV  
TDR&TXV  
FF1(B,C,D)NA018  
FF1(B,C,D)NA024  
FG3AAA024  
FK4CNF001  
FK4CNF002  
10.50  
10.50  
10.20  
10.20  
11.50  
11.50  
018-A, D  
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA018  
CC5A/CD5AA024  
CK3BA024  
CK5A/CK5BA018  
CK5A/CK5BA024  
17,200  
17,600  
17,600  
17,200  
17,600  
TDR  
TDR  
TDR  
TDR  
TDR  
11.00  
11.20  
11.20  
11.00  
11.20  
11.00  
11.20  
11.20  
11.00  
11.20  
10.10  
10.45  
10.60  
10.30  
10.60  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
CC5A/CD5AW024  
CK3BA024  
CK5A/CK5BW024  
17,600  
17,600  
17,600  
TDR  
TDR  
TDR  
11.20  
11.20  
11.20  
11.20  
11.20  
11.20  
10.25  
10.35  
10.35  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AW024  
CK5A/CK5BW024  
17,600  
17,600  
TDR  
TDR  
11.20  
11.20  
11.20  
11.20  
10.30  
10.45  
CC5A/CD5AA024*  
CC5A/CD5AA030  
CC5A/CD5AW024  
CC5A/CD5AW030  
CE3AA024  
22,400  
22,600  
22,400  
22,600  
22,600  
23,000  
22,600  
22,400  
22,600  
22,400  
22,600  
22,400  
22,600  
22,600  
23,000  
22,600  
23,000  
22,600  
23,200  
22,000  
23,200  
23,400  
23,600  
NONE  
NONE  
10.00  
10.00  
10.00  
10.00  
10.00  
10.20  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.20  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.20  
9.05  
9.10  
9.05  
9.10  
9.10  
9.20  
9.10  
9.15  
9.15  
9.15  
9.15  
9.15  
9.15  
9.20  
9.30  
9.20  
9.30  
9.05  
9.20  
8.95  
10.15  
10.20  
10.40  
NONE  
NONE  
NONE  
CE3AA030  
NONE  
CF5AA024  
NONE  
CK3BA024  
NONE  
CK3BA030  
NONE  
CK5A/CK5BA024  
CK5A/CK5BA030  
CK5A/CK5BW024  
CK5A/CK5BW030  
F(A,B)4AN(F,C)024  
F(A,B)4AN(F,C)030  
FC4BNF024  
NONE  
NONE  
NONE  
NONE  
TDR  
10.00  
10.20  
10.00  
10.20  
10.00  
10.00  
TDR  
TDR & TXV  
TDR & TXV  
TDR  
FC4BNF030  
FF1(B,C,D)NA024  
FF1(B,C,D)NA030  
FG3AAA024  
10.00  
10.00  
10.00  
TDR  
NONE  
TDR & TXV  
TDR & TXV  
TDR & TXV  
10.00  
FK4CNF001  
11.20  
11.30  
11.50  
FK4CNF002  
FK4CNF003  
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE  
024-A, D  
CC5A/CD5AA024  
CC5A/CD5AA030  
CC5A/CD5AW030  
CK5A/CK5BA024  
CK5A/CK5BA030  
CK5A/CK5BW030  
CK3BA024  
22,400  
22,600  
22,600  
22,400  
22,600  
22,600  
22,400  
22,600  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
11.00  
11.00  
10.50  
11.00  
11.00  
10.50  
11.00  
10.50  
11.00  
11.00  
10.50  
11.00  
11.00  
10.50  
11.00  
9.80  
9.95  
9.95  
9.90  
10.00  
10.00  
9.90  
CK3BA030  
10.00  
COILS + 355MAV042040 VARIABLE-SPEED FURNACE  
CC5A/CD5AW030  
CK5A/CK5BW030  
22,600  
22,600  
TDR  
TDR  
10.50  
10.50  
10.50  
10.50  
9.80  
9.85  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
CC5A/CD5AW024  
CC5A/CD5AW030  
CK3BA024  
22,400  
22,600  
22,400  
22,600  
22,400  
22,600  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
9.70  
9.80  
9.75  
9.85  
9.75  
9.85  
CK3BA030  
CK5A/CK5BW024  
CK5A/CK5BW030  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AW024  
CC5A/CD5AW030  
CK5A/CK5BW024  
CK5A/CK5BW030  
22,400  
22,600  
22,400  
22,600  
TDR  
TDR  
TDR  
TDR  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
9.90  
10.00  
9.95  
10.05  
See notes on page 14.  
—9—  
COMBINATION RATINGS Continued  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
BRYANT GAS  
FURNACE OR  
ACCESSORY  
TDR†  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
TOT. CAP.  
BTUH  
STANDARD  
RATING  
ACCESSORY  
TXV‡  
EERA  
CD5A/CD5AA030*  
CC5A/CD5AA036  
CC5A/CD5AW030  
CD5AW036  
28,000  
29,000  
28,000  
29,000  
27,800  
28,600  
28,800  
28,000  
29,000  
28,000  
29,000  
27,000  
29,000  
28,000  
29,000  
27,600  
28,200  
27,600  
28,200  
28,000  
28,000  
29,000  
29,200  
29,400  
29,600  
NONE  
NONE  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
11.00  
11.00  
11.50  
11.50  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.00  
10.00  
9.10  
9.30  
9.10  
9.30  
9.15  
9.25  
9.30  
9.10  
9.35  
9.10  
9.35  
9.35  
9.35  
9.10  
9.35  
9.20  
9.10  
9.20  
9.10  
9.10  
9.20  
9.95  
10.00  
10.30  
10.55  
NONE  
NONE  
CE3AA030  
NONE  
CE3AA036  
NONE  
CF5AA036  
NONE  
CK3BA030  
NONE  
CK3BA036  
NONE  
CK5A/CK5BA030  
CK5A/CK5BA036  
CK5A/CK5BN036  
CK5A/CK5BT036  
CK5A/CK5BW030  
CK5A/CK5BW036  
F(A,B)4AN(F,C)030  
F(A,B)4AN(F,C)036  
FC4BNF030  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
TDR  
TDR  
TDR & TXV  
TDR & TXV  
TDR  
FC4BNF036  
FF1(B,C,D)NA030  
FG3AAA036  
10.00  
10.10  
NONE  
10.10  
FK4CNF001  
TDR & TXV  
TDR & TXV  
TDR & TXV  
TDR & TXV  
FK4CNF002  
FK4CNF003  
FK4CNF005  
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA030  
CC5A/CD5AA036  
CC5A/CD5AW030  
CK3BA030  
28,000  
29,000  
28,000  
28,000  
29,000  
28,000  
29,000  
27,000  
29,000  
28,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
11.00  
10.50  
10.50  
11.00  
10.50  
11.00  
11.00  
11.00  
10.50  
10.50  
11.00  
10.50  
10.50  
11.00  
10.50  
11.00  
11.00  
11.00  
10.50  
9.70  
10.00  
9.70  
9.70  
CK3BA036  
10.05  
9.70  
CK5A/CK5BA030  
CK5A/CK5BA036  
CK5A/CK5BN036  
CK5A/CK5BT036  
CK5A/CK5BW030  
10.05  
9.90  
10.05  
9.70  
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE  
030-A, D  
CC5A/CD5AW030  
CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
28,000  
29,000  
28,000  
29,000  
TDR  
TDR  
TDR  
TDR  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
9.80  
10.15  
9.85  
10.20  
COILS + 355MAV042040 VARIABLE-SPEED FURNACE  
CC5A/CD5AW030  
CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
28,000  
29,000  
28,000  
29,000  
TDR  
TDR  
TDR  
TDR  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
9.50  
9.85  
9.50  
9.85  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA036  
CC5A/CD5AW030  
CK3BA030  
29,000  
28,000  
28,000  
29,000  
29,000  
29,000  
28,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
11.00  
10.50  
10.50  
11.00  
11.00  
11.00  
10.50  
11.00  
10.50  
10.50  
11.00  
11.00  
11.00  
10.50  
9.80  
9.50  
9.50  
9.85  
9.85  
9.85  
9.50  
CK3BA036  
CK5A/CK5BA036  
CK5A/CK5BT036  
CK5A/CK5BW030  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AW030  
CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
28,000  
29,000  
28,000  
29,000  
TDR  
TDR  
TDR  
TDR  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
9.55  
9.90  
9.60  
9.95  
COILS + 355MAV060080 VARIABLE-SPEED FURNACE  
CC5A/CD5AW030  
CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
28,000  
29,000  
28,000  
29,000  
TDR  
TDR  
TDR  
TDR  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
9.45  
9.80  
9.50  
9.85  
COILS + 355MAV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AW030  
CD5AW036  
CK5A/CK5BW030  
CK5A/CK5BW036  
28,000  
29,000  
28,000  
29,000  
TDR  
TDR  
TDR  
TDR  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
10.50  
11.00  
9.75  
10.10  
9.80  
10.10  
COILS + 355MAV060120 VARIABLE-SPEED FURNACE  
CD5AW036  
CK5A/CK5BW036  
29,000  
29,000  
TDR  
TDR  
11.00  
11.00  
11.00  
11.00  
10.05  
10.05  
CC5A/CD5AA036*  
CC5A/CD5AA042  
CC5A/CD5AW042  
CD5AW036  
33,800  
33,800  
33,800  
33,800  
33,400  
33,600  
33,600  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
9.20  
9.20  
9.15  
9.20  
9.10  
9.25  
9.15  
036-A, B, D, E  
CE3AA036  
CE3AA042  
CF5AA036  
See notes on page 14.  
—10—  
COMBINATION RATINGS Continued  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
BRYANT GAS  
FURNACE OR  
ACCESSORY  
TDR†  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
TOT. CAP.  
BTUH  
STANDARD  
RATING  
ACCESSORY  
TXV‡  
EERA  
CK3BA036  
CK3BA042  
33,800  
33,800  
33,800  
33,800  
31,400  
33,800  
33,800  
33,800  
33,800  
33,800  
33,000  
33,800  
34,800  
33,000  
32,600  
35,200  
33,000  
33,000  
33,600  
35,000  
NONE  
NONE  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.50  
10.00  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.20  
10.00  
10.00  
9.20  
9.20  
9.20  
9.20  
9.30  
9.20  
9.20  
9.20  
9.20  
9.15  
8.90  
9.15  
9.70  
8.90  
9.05  
10.55  
9.60  
9.60  
10.05  
10.35  
CK5A/CK5BA036  
CK5A/CK5BA042  
CK5A/CK5BN036  
CK5A/CK5BN042  
CK5A/CK5BT036  
CK5A/CK5BT042  
CK5A/CK5BW036  
F(A,B)4AN(F,B,C)042  
F(A,B)4AN(F,C)036  
FC4BN(F,B)042  
FC4BNB054  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
TDR  
TDR  
TDR & TXV  
TDR & TXV  
TDR & TXV  
NONE  
FC4BNF036  
FG3AAA036  
10.00  
10.00  
FK4CNB006  
TDR & TXV  
TDR & TXV  
TDR & TXV  
TDR & TXV  
TDR & TXV  
11.00  
10.00  
10.00  
10.50  
11.00  
FK4CNF001  
FK4CNF002  
FK4CNF003  
FK4CNF005  
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA036  
CK3BA036  
CK5A/CK5BA036  
CK5A/CK5BN036  
CK5A/CK5BT036  
33,400  
33,400  
33,400  
31,400  
33,400  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
9.65  
9.65  
9.65  
9.55  
9.65  
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW042  
CD5AW036  
33,400  
33,400  
33,400  
33,400  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.80  
10.80  
10.50  
10.80  
10.80  
10.80  
10.50  
10.80  
10.80  
10.50  
10.80  
10.80  
10.80  
10.50  
9.85  
9.80  
9.80  
9.85  
9.85  
9.85  
9.80  
CK3BA042  
CK5A/CK5BA042  
CK5A/CK5BT042  
CK5A/CK5BW036  
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BT042  
CK5A/CK5BW036  
33,400  
33,400  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
TDR  
TDR  
10.80  
10.50  
10.80  
10.80  
10.50  
10.80  
10.50  
10.80  
10.80  
10.50  
10.05  
10.00  
10.10  
10.10  
10.05  
036-A, B, D, E  
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BT042  
CK5A/CK5BW036  
33,400  
33,400  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
TDR  
TDR  
10.80  
10.50  
10.80  
10.80  
10.50  
10.80  
10.50  
10.80  
10.80  
10.50  
10.00  
9.95  
10.00  
10.00  
9.95  
COILS + 355MAV042040 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BT042  
33,400  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
TDR  
10.80  
10.50  
10.80  
10.80  
10.80  
10.50  
10.80  
10.80  
9.75  
9.70  
9.80  
9.80  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA036  
CK3BA036  
33,400  
33,400  
33,400  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.50  
10.80  
10.50  
10.50  
10.50  
10.50  
10.50  
10.80  
10.50  
10.50  
10.50  
9.70  
9.70  
9.75  
9.70  
9.70  
9.75  
CK3BA042  
CK5A/CK5BA036  
CK5A/CK5BT036  
CK5A/CK5BW036  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW042  
CD5AW036  
33,400  
33,400  
33,400  
33,400  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.80  
10.80  
10.50  
10.80  
10.80  
10.80  
10.50  
10.80  
10.80  
10.50  
10.80  
10.80  
10.80  
10.50  
9.80  
9.75  
9.75  
9.85  
9.85  
9.85  
9.80  
CK3BA042  
CK5A/CK5BA042  
CK5A/CK5BT042  
CK5A/CK5BW036  
COILS + 355MAV060080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW042  
CD5AW036  
33,400  
33,400  
33,400  
33,400  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.80  
10.80  
10.50  
10.80  
10.80  
10.80  
10.50  
10.80  
10.80  
10.50  
10.80  
10.80  
10.80  
10.50  
9.75  
9.70  
9.65  
9.75  
9.75  
9.75  
9.70  
CK3BA042  
CK5A/CK5BA042  
CK5A/CK5BT042  
CK5A/CK5BW036  
COILS + 355MAV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AW042  
CD5AW036  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
10.80  
10.80  
10.50  
10.80  
10.80  
10.50  
9.95  
9.90  
9.90  
See notes on page 14.  
—11—  
COMBINATION RATINGS Continued  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
BRYANT GAS  
FURNACE OR  
ACCESSORY  
TDR†  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
TOT. CAP.  
BTUH  
STANDARD  
RATING  
ACCESSORY  
TXV‡  
EERA  
CK5A/CK5BA042  
CK5A/CK5BT042  
CK5A/CK5BW036  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
10.80  
10.80  
10.50  
10.80  
10.80  
10.50  
10.00  
10.00  
9.95  
COILS + 355MAV060120 VARIABLE-SPEED FURNACE  
036-A, B, D, E  
CC5A/CD5AA042  
CD5AW036  
CK5A/CK5BA042  
CK5A/CK5BT042  
CK5A/CK5BW036  
33,400  
33,400  
33,400  
33,400  
33,400  
TDR  
TDR  
TDR  
TDR  
TDR  
10.80  
10.50  
10.80  
10.80  
10.50  
10.80  
10.50  
10.80  
10.80  
10.50  
9.90  
9.85  
9.95  
9.95  
9.90  
CC5A/CD5AA042*  
CC5A/CD5AC048  
CC5A/CD5AW042  
CC5A/CD5AW048  
CD5AA048  
40,000  
39,500  
40,000  
40,000  
40,000  
39,500  
40,500  
40,000  
40,000  
40,000  
40,000  
39,000  
39,000  
40,000  
40,000  
41,000  
40,000  
41,000  
41,500  
40,000  
40,000  
41,000  
41,500  
NONE  
NONE  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.10  
10.00  
10.10  
10.50  
10.00  
10.50  
11.00  
11.00  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.10  
10.00  
10.10  
9.00  
8.95  
9.00  
9.00  
9.00  
8.95  
9.10  
9.00  
9.00  
9.05  
9.00  
9.05  
9.00  
9.00  
9.00  
9.00  
8.90  
9.00  
8.90  
9.00  
9.60  
9.95  
10.15  
NONE  
NONE  
NONE  
CE3AA042  
NONE  
CE3AA048  
NONE  
CK3BA042  
NONE  
CK3BA048  
NONE  
CK5A/CK5BA042  
CK5A/CK5BA048  
CK5A/CK5BN042  
CK5A/CK5BN048  
CK5A/CK5BW048  
F(A,B)4AN(F,B)042  
F(A,B)4AN(F,B)048  
FC4BN(F,B)042  
FC4BN(F,B)048  
FC4BNB054  
NONE  
NONE  
NONE  
NONE  
NONE  
TDR  
TDR  
TDR&TXV  
TDR&TXV  
TDR&TXV  
NONE  
FG3AAA048  
10.10  
10.10  
FK4CNF003  
TDR&TXV  
TDR&TXV  
TDR&TXV  
FK4CNF005  
FK4CNF006  
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AC048  
CC5A/CD5AW042  
CC5A/CD5AW048  
CD5AA048  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.70  
10.50  
10.70  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
9.45  
9.45  
9.55  
9.45  
9.45  
9.55  
9.45  
9.45  
9.45  
9.55  
9.45  
CE3AA042  
CE3AA048  
CK3BA042  
CK3BA048  
CK5A/CK5BA042  
CK5A/CK5BA048  
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE  
042-A, B, C  
CC5A/CD5AA042  
CC5A/CD5AC048  
CC5A/CD5AW042  
CC5A/CD5AW048  
CD5AA048  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.70  
10.50  
10.70  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
9.60  
9.60  
9.60  
9.60  
9.60  
9.45  
9.45  
9.45  
9.60  
9.45  
9.45  
CE3AA042  
CE3AA048  
CK3BA042  
CK3BA048  
CK5A/CK5BA042  
CK5A/CK5BW048  
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AC048  
CC5A/CD5AW042  
CC5A/CD5AW048  
CD5AA048  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.70  
10.50  
10.70  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
9.50  
9.55  
9.50  
9.55  
9.55  
9.55  
9.55  
9.50  
9.50  
9.50  
9.55  
CE3AA042  
CE3AA048  
CK3BA042  
CK3BA048  
CK5A/CK5BA042  
CK5A/CK5BW048  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AC048  
CK3BA042  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
9.30  
9.45  
9.30  
9.45  
9.30  
9.45  
CK3BA048  
CK5A/CK5BA042  
CK5A/CK5BA048  
COILS + 355MAV060080 VARIABLE-SPEED FURNACE  
CK5A/CK5BA042  
CK5A/CK5BA048  
CK3BA042  
40,000  
40,000  
40,000  
40,000  
TDR  
TDR  
TDR  
TDR  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
9.30  
9.45  
9.30  
9.45  
CK3BA048  
See notes on page 14.  
—12—  
COMBINATION RATINGS Continued  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
BRYANT GAS  
FURNACE OR  
ACCESSORY  
TDR†  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
TOT. CAP.  
BTUH  
STANDARD  
RATING  
ACCESSORY  
TXV‡  
EERA  
COILS + 355MAV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AA042  
CC5A/CD5AC048  
CK3BA042  
40,000  
40,000  
40,000  
40,000  
40,000  
40,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
9.45  
9.45  
9.45  
9.45  
9.45  
9.45  
CK3BA048  
CK5A/CK5BA042  
CK5A/CK5BA048  
042-A, B, C  
COILS + 355MAV060120 VARIABLE-SPEED FURNACE  
CK3BA042  
CK3BA048  
CK5A/CK5BA042  
CK5A/CK5BW048  
40,000  
40,000  
40,000  
40,000  
TDR  
TDR  
TDR  
TDR  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
10.50  
10.70  
9.45  
9.45  
9.45  
9.45  
CC5A/CD5AA060  
CC5A/CD5AC048  
CC5A/CD5AW048  
CC5A/CD5AW060  
CD5A048*  
46,000  
45,000  
46,000  
47,500  
46,000  
46,500  
48,000  
46,000  
46,000  
46,000  
46,000  
46,000  
44,500  
46,000  
47,500  
47,000  
48,000  
49,000  
47,000  
47,500  
48,500  
48,500  
46,000  
47,000  
48,000  
49,000  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
NONE  
TDR  
10.00  
10.00  
10.00  
10.20  
10.00  
10.20  
10.20  
10.20  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.20  
10.50  
10.50  
11.00  
10.50  
10.50  
11.00  
11.00  
10.00  
10.20  
11.50  
11.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
11.00  
9.35  
9.25  
9.30  
9.55  
9.30  
9.30  
9.50  
9.40  
9.30  
9.30  
9.30  
9.35  
9.25  
9.30  
9.55  
9.15  
9.25  
9.55  
9.15  
9.25  
9.55  
9.50  
9.20  
9.35  
9.90  
10.20  
CE3AA048  
CE3AA060  
CF5AA048  
CK3BA048  
CK3BA060  
CK5A/CK5BA048  
CK5A/CK5BA060  
CK5A/CK5BN048  
CK5A/CK5BW048  
CK5A/CK5BX060  
F(A,B)4AN(F,B)048  
F(A,B)4AN(F,B)060  
FB4ANB070  
TDR  
TDR  
FC4BN(F,B)048  
FC4BN(F,B)060  
FC4BNB054  
TDR&TXV  
TDR&TXV  
TDR&TXV  
TDR&TXV  
NONE  
NONE  
TDR&TXV  
TDR  
FC4BNB070  
FG3AA048  
10.50  
10.50  
10.50  
10.50  
FG3AA060  
FK4CNF005  
FK4CNF006  
11.50  
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE  
CC5A/CD5AC048  
CC5A/CD5AW048  
CD5AA048  
45,500  
45,500  
45,500  
45,500  
46,000  
45,500  
45,500  
45,500  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.50  
10.50  
10.50  
11.00  
10.50  
11.00  
10.50  
10.50  
10.50  
10.50  
10.50  
11.00  
10.50  
11.00  
10.50  
9.35  
9.35  
9.35  
9.60  
9.60  
9.35  
9.35  
9.35  
CE3AA048  
CE3AA060  
CK3BA048  
CK3BA060  
048-A, B, C  
CK5A/CK5BA048  
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AW048  
CC5A/CD5AW060  
CD5AA048  
45,500  
45,500  
46,000  
45,500  
45,500  
45,500  
46,000  
45,500  
45,500  
45,500  
45,500  
46,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
11.00  
11.00  
11.50  
11.00  
11.00  
11.00  
11.50  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.50  
11.00  
11.00  
11.00  
11.50  
11.00  
11.00  
11.00  
11.00  
11.00  
9.20  
9.60  
9.90  
9.60  
9.60  
9.60  
9.60  
9.35  
9.35  
9.90  
9.60  
9.60  
CD5AC048  
CE3AA048  
CE3AA060  
CK3BA048  
CK3BA060  
CK5A/CK5BA060  
CK5A/CK5BW048  
CK5A/CK5BX060  
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AC048  
CC5A/CD5AW048  
CC5A/CD5AW060  
CD5AA048  
45,500  
45,500  
45,500  
46,000  
45,500  
45,500  
46,000  
45,500  
45,500  
45,500  
45,500  
46,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.50  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.00  
11.50  
11.00  
11.00  
11.00  
11.00  
11.00  
9.55  
9.55  
9.55  
9.80  
9.55  
9.55  
9.80  
9.55  
9.80  
9.80  
9.55  
9.80  
CE3AA048  
CE3AA060  
CK3BA048  
CK3BA060  
CK5A/CK5BA060  
CK5A/CK5BW048  
CK5A/CK5BX060  
COILS + 355MAV042040 VARIABLE-SPEED FURNACE  
45,500 TDR 10.50  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AW048  
10.50  
9.05  
CC5A/CD5AC048  
CK5A/CK5BA048  
45,500  
45,500  
TDR  
TDR  
10.80  
10.50  
10.80  
10.50  
9.30  
9.30  
See notes on page 14.  
—13—  
COMBINATION RATINGS Continued  
FACTORY-  
SUPPLIED  
ENHANCE-  
MENT  
BRYANT GAS  
FURNACE OR  
ACCESSORY  
TDR†  
UNIT  
SIZE-SERIES  
INDOOR  
MODEL  
TOT. CAP.  
BTUH  
STANDARD  
RATING  
ACCESSORY  
TXV‡  
EERA  
CK3BA048  
CK3BA060  
45,500  
45,500  
TDR  
TDR  
10.50  
11.00  
10.50  
11.00  
9.30  
9.15  
COILS + 355MAV060080 VARIABLE-SPEED FURNACE  
CK3BA048  
CK3BA060  
CK5A/CK5BA048  
CK5A/CK5BA060  
CK5A/CK5BX060  
45,500  
45,500  
45,500  
45,500  
46,000  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
11.00  
10.50  
10.50  
11.00  
10.50  
11.00  
10.50  
10.50  
11.00  
9.30  
9.15  
9.30  
9.15  
9.15  
COILS + 355MAV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AC048  
CK3BA048  
46,000  
45,500  
45,500  
45,500  
45,500  
45,500  
46,000  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
TDR  
10.50  
10.80  
10.80  
11.00  
10.80  
10.50  
11.00  
10.50  
10.80  
10.80  
11.00  
10.80  
10.50  
11.00  
9.15  
9.30  
9.30  
9.15  
9.30  
9.15  
9.15  
048-A, B, C  
CK3BA060  
CK5A/CK5BA048  
CK5A/CK5BA060  
CK5A/CK5BX060  
COILS + 355MAV060120 VARIABLE-SPEED FURNACE  
CK3BA048  
CK3BA060  
CK5A/CK5BA060  
CK5A/CK5BW048  
CK5A/CK5BX060  
45,500  
45,500  
45,500  
45,500  
46,000  
TDR  
TDR  
TDR  
TDR  
TDR  
10.80  
11.00  
10.50  
10.80  
11.00  
10.80  
11.00  
10.50  
10.80  
11.00  
9.30  
9.15  
9.15  
9.30  
9.15  
CC5A/CD5AA060  
CC5A/CD5AW060*  
CE3AA060  
CK5A/CK5BA060  
CK5A/CK5BN060  
CK5A/CK5BX060  
CK3BA060  
F(A,B)4AN(F,B)060  
FB4ANB070  
FC4BN(F,B)060  
FC4BNB070  
FG3AAA060  
FK4CNB006  
54,500  
57,000  
57,500  
54,500  
54,500  
57,000  
54,500  
57,500  
58,000  
57,000  
58,000  
56,500  
58,000  
NONE  
NONE  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.00  
10.50  
10.00  
10.50  
10.00  
11.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.50  
10.00  
10.50  
9.25  
9.40  
9.50  
9.25  
9.50  
9.50  
9.50  
9.00  
9.35  
9.00  
9.35  
9.35  
10.00  
NONE  
NONE  
NONE  
NONE  
NONE  
TDR  
TDR  
TDR&TXV  
TDR&TXV  
NONE  
10.20  
10.20  
TDR&TXV  
060-A, B, E  
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AW060  
CK3BA060  
CK5A/CK5BA060  
CK5A/CK5BX060  
54,500  
54,500  
54,500  
54,500  
57,000  
TDR  
TDR  
TDR  
TDR  
TDR  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
9.40  
9.65  
9.50  
9.25  
9.40  
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE  
CC5A/CD5AA060  
CC5A/CD5AW060  
CK3BA060  
CK5A/CK5BA060  
CK5A/CK5BX060  
54,500  
54,500  
54,500  
54,500  
54,500  
TDR  
TDR  
TDR  
TDR  
TDR  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
10.70  
9.20  
9.50  
9.50  
9.25  
9.40  
*
Tested Combination.  
In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use  
either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the  
394HAD.  
TXV must be hard shutoff type; based on computer simulation.  
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.  
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other com-  
binations are determined under DOE computer simulation procedures.  
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.  
4. Minimum outdoor operating ambient in cooling mode is 55°F (12.8°C), maximum 125°F (51.7°C).  
—14—  
DETAILED COOLING CAPACITIES*  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
525  
600  
675  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C018-A, D Outdoor Section With CC5A/CD5AA018 Indoor Section  
72  
67  
62  
57  
21.0 10.0 1.77 19.9 9.58 1.88 18.7 9.11 1.98 17.4 8.65 2.09 16.2 8.18 2.18 14.9 7.73 2.27  
19.1 12.3 1.71 18.0 11.9 1.81 16.8 11.4 1.91 15.7 10.9 2.01 14.5 10.4 2.09 13.4 9.96 2.17  
17.2 14.6 1.65 16.2 14.1 1.75 15.1 13.6 1.84 14.1 13.0 1.93 13.0 12.5 2.01 12.0 11.9 2.08  
15.9 15.9 1.61 15.1 15.1 1.71 14.3 14.3 1.81 13.5 13.5 1.90 12.7 12.7 1.99 11.9 11.9 2.07  
72  
67  
62  
57  
21.5 10.4 1.82 20.3 9.97 1.92 19.0 9.50 2.03 17.8 9.02 2.13 16.4 8.55 2.23 15.2 8.09 2.32  
19.5 13.0 1.75 18.4 12.5 1.86 17.2 12.0 1.96 16.0 11.5 2.05 14.8 11.1 2.14 13.6 10.6 2.22  
17.7 15.5 1.70 16.6 15.0 1.79 15.5 14.4 1.89 14.4 13.8 1.98 13.3 13.2 2.06 12.3 12.3 2.14  
16.6 16.6 1.67 15.8 15.8 1.77 14.9 14.9 1.87 14.1 14.1 1.96 13.2 13.2 2.05 12.3 12.3 2.14  
72  
67  
62  
57  
21.9 10.8 1.86 20.7 10.4 1.97 19.4 9.86 2.07 18.0 9.39 2.18 16.7 8.90 2.27 15.3 8.44 2.36  
19.9 13.7 1.80 18.7 13.2 1.90 17.5 12.7 2.00 16.3 12.2 2.09 15.0 11.7 2.18 13.8 11.2 2.26  
18.0 16.4 1.74 16.9 15.8 1.84 15.8 15.2 1.93 14.6 14.5 2.02 13.6 13.6 2.11 12.7 12.7 2.20  
17.2 17.2 1.71 16.3 16.3 1.82 15.4 15.4 1.92 14.5 14.5 2.01 13.6 13.6 2.11 12.7 12.7 2.20  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Unit  
Size  
Indoor  
Unit  
Size  
Capacity  
1.00  
1.02  
1.02  
1.03  
1.03  
1.02  
1.00  
1.02  
1.02  
0.98  
1.02  
1.02  
1.00  
1.02  
1.02  
Power  
1.00  
1.01  
1.01  
1.01  
1.01  
1.02  
1.01  
1.02  
1.02  
0.99  
1.01  
1.01  
0.97  
1.02  
1.01  
Section  
Capacity  
1.02  
Power  
0.93  
CC5A/CD5AA  
018  
024  
024  
024  
024  
024  
018  
024  
024  
018  
024  
024  
018  
024  
024  
FK4CNF  
001  
002  
1.02  
0.93  
CC5A/CD5AW  
CE3AA  
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
018  
024  
024  
018  
024  
1.00  
1.02  
1.02  
1.00  
1.02  
0.91  
0.92  
0.92  
0.92  
0.92  
CF5AA  
CK3BA  
CK3BA  
CK5A/CK5BA  
CK5A/CK5BA  
CK5A/CK5BW  
F(A,B)4AN(F,C)  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
CC5A/CD5AW  
CK3BA  
024  
024  
024  
1.02  
1.02  
1.02  
0.95  
0.96  
0.96  
FC4BNF  
CK5A/CK5BW  
FF1(B,C,D)NA  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AW  
CK5A/CK5BW  
024  
024  
1.02  
1.02  
0.95  
0.95  
FG3AAA  
See notes on page 24.  
—15—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
700  
800  
900  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C024-A, D Outdoor Section With CC5A/CD5AA024 Indoor Section  
72  
67  
62  
57  
27.2 13.2 2.34 25.8 12.6 2.46 24.3 12.0 2.57 22.7 11.5 2.68 21.1 10.9 2.78 19.5 10.3 2.88  
24.8 16.4 2.25 23.4 15.8 2.36 22.0 15.2 2.47 20.5 14.6 2.57 19.1 14.0 2.67 17.6 13.4 2.76  
22.4 19.5 2.17 21.1 18.9 2.27 19.8 18.2 2.37 18.5 17.6 2.47 17.2 16.8 2.56 15.9 15.9 2.65  
21.0 21.0 2.12 20.0 20.0 2.23 19.0 19.0 2.34 18.0 18.0 2.45 17.0 17.0 2.55 15.9 15.9 2.65  
72  
67  
62  
57  
27.8 13.8 2.40 26.3 13.2 2.52 24.7 12.6 2.63 23.1 12.0 2.75 21.5 11.4 2.85 19.8 10.9 2.95  
25.3 17.4 2.31 23.9 16.8 2.42 22.4 16.2 2.53 20.9 15.6 2.64 19.4 15.0 2.73 17.8 14.4 2.82  
23.0 20.9 2.23 21.6 20.2 2.33 20.2 19.4 2.44 18.9 18.6 2.53 17.6 17.6 2.63 16.5 16.5 2.73  
21.9 21.9 2.19 20.9 20.9 2.30 19.8 19.8 2.42 18.7 18.7 2.52 17.6 17.6 2.63 16.5 16.5 2.73  
72  
67  
62  
57  
28.3 14.3 2.46 26.7 13.7 2.58 25.1 13.1 2.69 23.4 12.5 2.80 21.7 11.9 2.91 20.0 11.4 3.00  
25.8 18.3 2.37 24.3 17.7 2.48 22.7 17.1 2.59 21.2 16.5 2.69 19.6 15.8 2.79 18.0 15.2 2.87  
23.4 22.0 2.28 22.0 21.3 2.39 20.6 20.4 2.50 19.3 19.3 2.60 18.1 18.1 2.70 16.9 16.9 2.80  
22.7 22.7 2.26 21.6 21.6 2.37 20.5 20.5 2.49 19.3 19.3 2.60 18.1 18.1 2.70 16.9 16.9 2.81  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Unit  
Size  
Indoor  
Section  
Unit  
Size  
Capacity  
1.00  
1.01  
1.00  
1.01  
1.01  
1.03  
1.01  
1.00  
1.01  
1.00  
1.01  
1.00  
1.01  
1.01  
1.03  
1.01  
1.03  
1.01  
1.04  
0.98  
1.04  
1.04  
1.05  
Power  
1.00  
1.00  
1.00  
1.00  
1.00  
1.01  
1.00  
1.00  
1.01  
1.00  
1.01  
1.00  
1.01  
1.00  
1.00  
1.00  
1.00  
1.01  
1.02  
0.99  
0.93  
0.94  
0.92  
Capacity  
Power  
CC5A/CD5AA  
CC5A/CD5AW  
CE3AA  
024  
030  
024  
030  
024  
030  
024  
024  
030  
024  
030  
024  
030  
024  
030  
024  
030  
024  
030  
024  
001  
002  
003  
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
024  
030  
030  
024  
030  
024  
030  
030  
1.00  
1.01  
1.01  
1.00  
1.01  
1.00  
1.01  
1.01  
0.92  
0.92  
0.92  
0.93  
0.93  
0.93  
0.93  
0.93  
CC5A/CD5AW  
CK3BA  
CF5AA  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BA  
CK5A/CK5BW  
CK3BA  
COILS + 355MAV042040 VARIABLE-SPEED FURNACE  
CC5A/CD5AW  
CK5A/CK5BW  
030  
030  
1.01  
1.01  
0.95  
0.95  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
F(A,B)4AN(F,C)  
FC4BNF  
CC5A/CD5AW  
CK3BA  
024  
030  
024  
030  
024  
030  
1.00  
1.01  
1.00  
1.01  
1.00  
1.01  
0.95  
0.95  
0.96  
0.95  
0.96  
0.95  
FF1(B,C,D)NA  
CK5A/CK5BW  
FG3AAA  
FK4CNF  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AW  
024  
030  
024  
030  
1.00  
1.01  
1.00  
1.01  
0.94  
0.94  
0.94  
0.94  
CK5A/CK5BW  
See notes on page 24.  
—16—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
875  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C030-A, D Outdoor Section With CC5A/CD5AA030 Indoor Section  
72  
67  
62  
57  
34.0 16.4 2.85 32.2 15.7 3.01 30.3 15.0 3.17 28.4 14.3 3.33 26.5 13.6 3.49 24.6 12.9 3.64  
30.9 20.4 2.74 29.2 19.7 2.89 27.5 19.0 3.04 25.7 18.2 3.20 23.9 17.5 3.34 22.2 16.8 3.49  
28.0 24.3 2.63 26.4 23.5 2.78 24.8 22.7 2.92 23.2 21.9 3.07 21.6 21.0 3.21 20.0 20.0 3.35  
26.2 26.2 2.57 25.0 25.0 2.73 23.8 23.8 2.88 22.5 22.5 3.04 21.3 21.3 3.19 20.0 20.0 3.35  
72  
67  
62  
57  
34.8 17.1 2.93 32.8 16.4 3.09 30.9 15.7 3.25 28.9 15.0 3.41 26.9 14.3 3.57 24.9 13.6 3.72  
31.6 21.6 2.82 29.8 20.9 2.97 28.0 20.1 3.12 26.2 19.4 3.27 24.3 18.7 3.42 22.5 17.9 3.57  
28.6 25.9 2.71 27.0 25.1 2.86 25.3 24.2 3.00 23.7 23.2 3.15 22.1 22.1 3.30 20.7 20.7 3.45  
27.3 27.3 2.66 26.0 26.0 2.82 24.7 24.7 2.98 23.4 23.4 3.13 22.1 22.1 3.29 20.7 20.7 3.45  
1000  
1125  
72  
67  
62  
57  
35.3 17.8 3.01 33.3 17.1 3.17 31.3 16.3 3.32 29.3 15.6 3.48 27.3 14.9 3.64 25.2 14.2 3.80  
32.2 22.7 2.89 30.3 22.0 3.04 28.4 21.2 3.19 26.5 20.5 3.35 24.6 19.7 3.50 22.7 19.0 3.64  
29.1 27.4 2.78 27.5 26.4 2.93 25.8 25.4 3.08 24.2 24.2 3.23 22.7 22.7 3.39 21.3 21.3 3.54  
28.3 28.3 2.75 26.9 26.9 2.91 25.5 25.5 3.06 24.1 24.1 3.23 22.7 22.7 3.39 21.3 21.3 3.55  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Unit  
Size  
Indoor  
Section  
Unit  
Size  
Capacity  
1.04  
1.00  
1.00  
1.04  
0.99  
1.02  
1.03  
1.00  
1.04  
1.00  
1.04  
0.96  
1.04  
1.00  
1.04  
0.99  
1.01  
0.99  
1.01  
1.00  
1.00  
1.04  
1.04  
1.05  
1.06  
Power  
1.01  
1.00  
1.00  
1.01  
1.00  
1.01  
1.01  
1.00  
1.01  
1.00  
1.01  
1.01  
1.01  
1.00  
1.01  
1.00  
1.02  
1.00  
1.02  
1.02  
1.00  
0.94  
0.94  
0.93  
0.94  
Capacity  
Power  
CC5A/CD5AA  
CC5A/CD5AW  
CD5A/CD5AA  
CD5AW  
036  
030  
030  
036  
030  
036  
036  
030  
036  
030  
036  
036  
036  
030  
036  
030  
036  
030  
036  
030  
036  
001  
002  
003  
005  
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE  
CC5A/CD5AW  
CD5AW  
030  
036  
030  
036  
1.00  
1.04  
1.00  
1.04  
0.93  
0.93  
0.93  
0.93  
CK5A/CK5BW  
CE3AA  
COILS + 355MAV042040 VARIABLE-SPEED FURNACE  
CF5AA  
CK3BA  
CC5A/CD5AW  
CD5AW  
030  
036  
030  
036  
1.00  
1.04  
1.00  
1.04  
0.97  
0.97  
0.97  
0.97  
CK5A/CK5BW  
CK5A/CK5BA  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
CK5A/CK5BN  
CK5A/CK5BT  
CK5A/CK5BW  
CC5A/CD5AA  
CC5A/CD5AW  
CK3BA  
036  
030  
030  
036  
036  
036  
030  
1.04  
1.00  
1.00  
1.04  
1.04  
1.04  
1.00  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
0.97  
F(A,B)4AN(F,C)  
FC4BNF  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BW  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
FF1(B,C,D)NA  
FG3AAA  
CC5A/CD5AA  
CD5AW  
030  
036  
030  
036  
1.00  
1.04  
1.00  
1.04  
0.96  
0.97  
0.96  
0.97  
FK4CNF  
CK5A/CK5BW  
COILS + 355MAV060080 VARIABLE-SPEED FURNACE  
CC5A/CD5AW  
CD5AW  
030  
036  
030  
036  
1.00  
1.04  
1.00  
1.04  
0.97  
0.97  
0.97  
0.97  
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
030  
036  
030  
030  
036  
030  
036  
036  
036  
030  
1.00  
1.04  
1.00  
1.00  
1.04  
1.00  
1.04  
0.96  
1.04  
1.00  
0.94  
0.94  
0.94  
0.94  
0.94  
0.94  
0.94  
0.95  
0.94  
0.94  
CK5A/CK5BW  
CC5A/CD5AW  
CK3BA  
COILS + 355MAV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AW  
CD5AW  
030  
036  
030  
036  
1.00  
1.04  
1.00  
1.04  
0.95  
0.95  
0.95  
0.95  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BN  
CK5A/CK5BT  
COILS + 355MAV060120 VARIABLE-SPEED FURNACE  
CD5AW  
036  
036  
1.04  
1.04  
0.96  
0.96  
CK5A/CK5BW  
CK5A/CK5BW  
See notes on page 24.  
—17—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
1050  
1200  
1350  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C036-A, B, D, E Outdoor Section With CC5A/CD5AA036 Indoor Section  
72  
67  
62  
57  
41.3 20.5 3.41 39.1 19.6 3.61 36.8 18.8 3.81 34.5 18.0 4.00 32.2 17.1 4.19 29.9 16.3 4.38  
37.6 25.8 3.28 35.5 25.0 3.47 33.4 24.1 3.65 31.3 23.3 3.84 29.1 22.4 4.02 27.0 21.6 4.20  
34.1 31.0 3.16 32.2 30.0 3.33 30.3 29.0 3.51 28.4 28.0 3.69 26.6 26.6 3.87 25.0 25.0 4.06  
32.8 32.8 3.10 31.2 31.2 3.30 29.7 29.7 3.49 28.2 28.2 3.68 26.6 26.6 3.87 25.0 25.0 4.06  
72  
67  
62  
57  
42.1 21.4 3.51 39.8 20.6 3.70 37.4 19.7 3.90 35.1 18.9 4.09 32.6 18.0 4.29 30.2 17.2 4.47  
38.4 27.5 3.37 36.2 26.6 3.56 34.0 25.7 3.74 31.8 24.8 3.93 29.6 23.9 4.11 27.3 23.1 4.29  
34.9 33.1 3.24 33.0 32.0 3.42 31.0 30.8 3.61 29.2 29.2 3.80 27.5 27.5 3.99 25.8 25.8 4.19  
34.1 34.1 3.22 32.5 32.5 3.41 30.9 30.9 3.60 29.2 29.2 3.80 27.5 27.5 3.99 25.8 25.8 4.19  
72  
67  
62  
57  
42.7 22.3 3.59 40.3 21.4 3.79 37.9 20.6 3.98 35.4 19.7 4.18 33.0 18.9 4.37 30.5 18.1 4.56  
38.9 29.0 3.45 36.7 28.1 3.64 34.4 27.2 3.83 32.1 26.3 4.01 29.8 25.4 4.19 27.6 24.5 4.37  
35.6 34.9 3.33 33.6 33.5 3.52 31.8 31.8 3.71 30.1 30.1 3.91 28.3 28.3 4.10 26.5 26.5 4.30  
35.2 35.2 3.32 33.5 33.5 3.51 31.8 31.8 3.71 30.1 30.1 3.91 28.3 28.3 4.11 26.5 26.5 4.30  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Unit  
Size  
Indoor  
Section  
Unit  
Size  
Capacity  
1.00  
1.00  
1.00  
1.00  
0.99  
0.99  
0.99  
1.00  
1.00  
1.00  
1.00  
0.93  
1.00  
1.00  
1.00  
1.00  
1.00  
0.98  
1.00  
1.03  
0.98  
0.96  
1.04  
0.98  
0.98  
0.99  
1.04  
Power  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.97  
1.00  
1.00  
1.00  
1.00  
1.01  
1.01  
1.01  
1.01  
1.01  
0.99  
0.93  
0.94  
0.95  
0.92  
0.93  
Capacity  
Power  
CC5A/CD5AA  
036  
042  
042  
036  
036  
042  
036  
036  
042  
036  
042  
036  
042  
036  
042  
036  
042  
036  
042  
054  
036  
036  
006  
001  
002  
003  
005  
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CD5AW  
042  
036  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.92  
0.92  
0.92  
0.92  
0.92  
CC5A/CD5AW  
CD5AW  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BW  
CE3AA  
CF5AA  
CK3BA  
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CD5AW  
042  
036  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.92  
0.93  
0.92  
0.92  
0.93  
CK5A/CK5BA  
CK5A/CK5BN  
CK5A/CK5BT  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BW  
COILS + 355MAV042040 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CD5AW  
042  
036  
042  
042  
0.99  
0.99  
0.99  
0.99  
0.93  
0.94  
0.93  
0.93  
CK5A/CK5BW  
F(A,B)4AN(F,B,C)  
F(A,B)4AN(F,C)  
FC4BN(F,B)  
FC4BNB  
CK5A/CK5BA  
CK5A/CK5BT  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CK3BA  
036  
036  
042  
036  
036  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
0.94  
0.94  
0.93  
0.94  
0.94  
0.94  
FC4BNF  
FG3AAA  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BW  
FK4CNB  
FK4CNF  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CD5AW  
042  
042  
036  
042  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
0.93  
0.92  
0.93  
0.93  
0.93  
0.93  
0.93  
COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CK3BA  
036  
036  
036  
036  
036  
0.99  
0.99  
0.99  
0.93  
0.99  
0.95  
0.95  
0.95  
0.96  
0.95  
CK3BA  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BW  
CK5A/CK5BA  
CK5A/CK5BN  
CK5A/CK5BT  
COILS + 355MAV060080 VARIABLE-SPEED FURNACE  
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AW  
CD5AW  
042  
042  
036  
042  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
0.93  
0.93  
0.94  
0.93  
0.93  
0.93  
0.94  
CC5A/CD5AA  
CC5A/CD5AW  
CD5AW  
042  
042  
036  
042  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
0.93  
0.93  
0.94  
0.93  
0.93  
0.93  
0.94  
CK3BA  
CK3BA  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BW  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BW  
See notes on page 24.  
—18—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
1050  
1200  
1350  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C036-A, B, D, E Outdoor Section With CC5A/CD5AA036 Indoor Section Continued  
72  
67  
62  
57  
41.3 20.5 3.41 39.1 19.6 3.61 36.8 18.8 3.81 34.5 18.0 4.00 32.2 17.1 4.19 29.9 16.3 4.38  
37.6 25.8 3.28 35.5 25.0 3.47 33.4 24.1 3.65 31.3 23.3 3.84 29.1 22.4 4.02 27.0 21.6 4.20  
34.1 31.0 3.16 32.2 30.0 3.33 30.3 29.0 3.51 28.4 28.0 3.69 26.6 26.6 3.87 25.0 25.0 4.06  
32.8 32.8 3.10 31.2 31.2 3.30 29.7 29.7 3.49 28.2 28.2 3.68 26.6 26.6 3.87 25.0 25.0 4.06  
72  
67  
62  
57  
42.1 21.4 3.51 39.8 20.6 3.70 37.4 19.7 3.90 35.1 18.9 4.09 32.6 18.0 4.29 30.2 17.2 4.47  
38.4 27.5 3.37 36.2 26.6 3.56 34.0 25.7 3.74 31.8 24.8 3.93 29.6 23.9 4.11 27.3 23.1 4.29  
34.9 33.1 3.24 33.0 32.0 3.42 31.0 30.8 3.61 29.2 29.2 3.80 27.5 27.5 3.99 25.8 25.8 4.19  
34.1 34.1 3.22 32.5 32.5 3.41 30.9 30.9 3.60 29.2 29.2 3.80 27.5 27.5 3.99 25.8 25.8 4.19  
72  
67  
62  
57  
42.7 22.3 3.59 40.3 21.4 3.79 37.9 20.6 3.98 35.4 19.7 4.18 33.0 18.9 4.37 30.5 18.1 4.56  
38.9 29.0 3.45 36.7 28.1 3.64 34.4 27.2 3.83 32.1 26.3 4.01 29.8 25.4 4.19 27.6 24.5 4.37  
35.6 34.9 3.33 33.6 33.5 3.52 31.8 31.8 3.71 30.1 30.1 3.91 28.3 28.3 4.10 26.5 26.5 4.30  
35.2 35.2 3.32 33.5 33.5 3.51 31.8 31.8 3.71 30.1 30.1 3.91 28.3 28.3 4.11 26.5 26.5 4.30  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Unit  
Size  
Indoor  
Section  
Unit  
Size  
Capacity  
Power  
Capacity  
Power  
COILS + 355MAV060100 VARIABLE-SPEED FURNACE  
COILS + 355MAV060120 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
042  
042  
036  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.99  
0.92  
0.92  
0.92  
0.92  
0.92  
0.92  
CC5A/CD5AA  
CD5AW  
042  
036  
042  
042  
036  
0.99  
0.99  
0.99  
0.99  
0.99  
0.92  
0.92  
0.92  
0.92  
0.92  
CC5A/CD5AW  
CD5AW  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BW  
CK5A/CK5BA  
CK5A/CK5BT  
CK5A/CK5BW  
See notes on page 24.  
—19—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C042-A, B, C Outdoor Section With CC5A/CD5AA042 Indoor Section  
72  
67  
62  
57  
48.6 23.6 4.08 45.9 22.6 4.35 43.2 21.6 4.60 40.5 20.6 4.85 37.7 19.6 5.08 34.8 18.5 5.31  
44.2 29.5 3.92 41.8 28.4 4.17 39.3 27.4 4.41 36.7 26.3 4.64 34.1 25.3 4.86 31.2 24.2 5.06  
40.2 35.2 3.77 37.9 34.0 4.01 35.5 32.9 4.23 33.2 31.7 4.45 30.8 30.3 4.65 28.2 28.2 4.86  
37.8 37.8 3.69 36.1 36.1 3.93 34.3 34.3 4.17 32.5 32.5 4.40 30.5 30.5 4.63 28.2 28.2 4.86  
1225  
1400  
1575  
72  
67  
62  
57  
49.6 24.7 4.19 46.8 23.6 4.45 44.0 22.6 4.71 41.1 21.6 4.96 38.2 20.5 5.20 35.3 19.5 5.42  
45.2 31.2 4.03 42.6 30.2 4.28 40.0 29.1 4.52 37.4 28.0 4.75 34.7 27.0 4.97 31.8 25.8 5.17  
41.1 37.5 3.88 38.7 36.3 4.11 36.3 35.0 4.35 34.0 33.6 4.57 31.7 31.7 4.78 29.3 29.3 5.01  
39.4 39.4 3.82 37.6 37.6 4.07 35.7 35.7 4.31 33.7 33.7 4.55 31.7 31.7 4.78 29.3 29.3 5.01  
72  
67  
62  
57  
50.4 25.6 4.29 47.5 24.6 4.55 44.6 23.5 4.81 41.6 22.5 5.06 38.6 21.5 5.30 35.6 20.4 5.52  
46.0 32.9 4.13 43.3 31.8 4.38 40.6 30.8 4.62 37.8 29.7 4.85 35.0 28.6 5.07 32.1 27.4 5.27  
41.8 39.7 3.98 39.4 38.3 4.22 37.0 36.7 4.45 34.8 34.8 4.68 32.6 32.6 4.92 30.3 30.3 5.15  
40.8 40.8 3.94 38.8 38.8 4.19 36.8 36.8 4.44 34.8 34.8 4.69 32.6 32.6 4.92 30.3 30.3 5.15  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Unit  
Size  
Indoor  
Unit  
Size  
Capacity  
1.00  
0.99  
1.00  
1.00  
1.00  
0.99  
1.01  
1.00  
1.00  
1.00  
1.00  
0.98  
0.98  
1.00  
1.00  
1.02  
1.00  
1.02  
1.04  
1.00  
1.00  
1.02  
1.04  
Power  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.01  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.01  
1.02  
1.02  
1.02  
1.02  
1.00  
0.94  
0.96  
0.95  
Section  
Capacity  
1.00  
Power  
0.93  
0.94  
0.94  
0.93  
0.93  
0.93  
0.93  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
042  
048  
042  
048  
048  
042  
048  
042  
048  
042  
048  
042  
048  
048  
042  
048  
042  
048  
054  
048  
003  
005  
006  
CD5AA  
CE3AA  
048  
042  
048  
042  
048  
042  
048  
1.00  
1.00  
CK3BA  
1.00  
CD5A/CD5BA  
CE3AA  
1.00  
CK5A/CK5BA  
CK5A/CK5BW  
1.00  
1.00  
CK3BA  
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
042  
048  
042  
048  
048  
042  
048  
042  
048  
042  
048  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.94  
0.93  
0.94  
0.94  
0.94  
0.95  
0.95  
0.93  
0.93  
0.93  
0.93  
CK5A/CK5BA  
CK5A/CK5BN  
CD5AA  
CE3AA  
CK5A/CK5BW  
F(A,B)4AN(F,B)  
CK3BA  
FC4BN(F,B)  
CK5A/CK5BA  
CK5A/CK5BW  
FC4BNB  
FG3AAA  
FK4CNF  
COILS + 355MAV042040 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
042  
048  
042  
048  
1.00  
1.00  
1.00  
1.00  
0.95  
0.93  
0.95  
0.93  
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
042  
048  
042  
048  
048  
042  
048  
042  
048  
042  
048  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.95  
0.93  
0.94  
0.94  
0.94  
0.95  
0.95  
0.95  
0.95  
0.95  
0.95  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
042  
048  
042  
048  
042  
042  
1.00  
1.00  
1.00  
1.00  
1.00  
0.98  
0.95  
0.93  
0.95  
0.93  
0.95  
0.95  
CD5A/CD5BA  
CE3AA  
CK3BA  
CK5A/CK5BN  
CK3BA  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
042  
048  
042  
048  
042  
048  
042  
048  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
1.00  
0.95  
0.93  
0.95  
0.93  
0.95  
0.95  
0.95  
0.95  
CK5A/CK5BA  
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
042  
048  
042  
048  
1.00  
1.00  
1.00  
1.00  
0.93  
0.92  
0.93  
0.93  
CK3BA  
CK5A/CK5BA  
See notes on page 24.  
—20—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C042-A, B, C Outdoor Section With CC5A/CD5AA042 Indoor Section Continued  
72  
67  
62  
57  
48.6 23.6 4.08 45.9 22.6 4.35 43.2 21.6 4.60 40.5 20.6 4.85 37.7 19.6 5.08 34.8 18.5 5.31  
44.2 29.5 3.92 41.8 28.4 4.17 39.3 27.4 4.41 36.7 26.3 4.64 34.1 25.3 4.86 31.2 24.2 5.06  
40.2 35.2 3.77 37.9 34.0 4.01 35.5 32.9 4.23 33.2 31.7 4.45 30.8 30.3 4.65 28.2 28.2 4.86  
37.8 37.8 3.69 36.1 36.1 3.93 34.3 34.3 4.17 32.5 32.5 4.40 30.5 30.5 4.63 28.2 28.2 4.86  
1225  
1400  
1575  
72  
67  
62  
57  
49.6 24.7 4.19 46.8 23.6 4.45 44.0 22.6 4.71 41.1 21.6 4.96 38.2 20.5 5.20 35.3 19.5 5.42  
45.2 31.2 4.03 42.6 30.2 4.28 40.0 29.1 4.52 37.4 28.0 4.75 34.7 27.0 4.97 31.8 25.8 5.17  
41.1 37.5 3.88 38.7 36.3 4.11 36.3 35.0 4.35 34.0 33.6 4.57 31.7 31.7 4.78 29.3 29.3 5.01  
39.4 39.4 3.82 37.6 37.6 4.07 35.7 35.7 4.31 33.7 33.7 4.55 31.7 31.7 4.78 29.3 29.3 5.01  
72  
67  
62  
57  
50.4 25.6 4.29 47.5 24.6 4.55 44.6 23.5 4.81 41.6 22.5 5.06 38.6 21.5 5.30 35.6 20.4 5.52  
46.0 32.9 4.13 43.3 31.8 4.38 40.6 30.8 4.62 37.8 29.7 4.85 35.0 28.6 5.07 32.1 27.4 5.27  
41.8 39.7 3.98 39.4 38.3 4.22 37.0 36.7 4.45 34.8 34.8 4.68 32.6 32.6 4.92 30.3 30.3 5.15  
40.8 40.8 3.94 38.8 38.8 4.19 36.8 36.8 4.44 34.8 34.8 4.69 32.6 32.6 4.92 30.3 30.3 5.15  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Unit  
Size  
Indoor  
Unit  
Size  
Capacity  
Power  
Section  
Capacity  
1.00  
Power  
0.94  
COILS + 355MAV060080 VARIABLE-SPEED FURNACE  
CK3BA  
042  
048  
042  
048  
CK5A/CK5BA  
CK3BA  
042  
048  
042  
048  
1.00  
1.00  
1.00  
1.00  
0.95  
0.95  
0.95  
0.95  
1.00  
0.94  
CK5A/CK5BA  
1.00  
0.94  
1.00  
0.94  
COILS + 355MAV060120 VARIABLE-SPEED FURNACE  
COILS + 355MAV060100 VARIABLE-SPEED FURNACE  
CK3BA  
042  
048  
042  
048  
1.00  
1.00  
1.00  
1.00  
0.94  
0.94  
0.94  
0.94  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
042  
048  
042  
048  
1.00  
1.00  
1.00  
1.00  
0.94  
0.93  
0.94  
0.93  
CK5A/CK5BA  
CK5A/CK5BW  
See notes on page 24.  
—21—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
1400  
1600  
1800  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C048-A, B, C Outdoor Section With CD5AA048 Indoor Section  
72  
67  
62  
57  
54.3 26.2 4.17 51.9 25.3 4.65 49.5 24.4 5.18 47.0 23.5 5.75 44.4 22.6 6.35 41.8 21.6 6.99  
49.6 32.8 4.07 47.4 31.8 4.55 45.2 30.9 5.06 42.9 30.0 5.61 40.5 29.0 6.21 38.1 28.0 6.83  
45.2 39.2 3.99 43.2 38.2 4.45 41.1 37.2 4.95 39.0 36.1 5.49 36.8 35.0 6.07 34.4 33.6 6.66  
42.4 42.4 3.94 40.9 40.9 4.41 39.3 39.3 4.91 37.7 37.7 5.45 36.0 36.0 6.03 33.9 33.9 6.64  
72  
67  
62  
57  
55.4 27.4 4.28 52.9 26.5 4.76 50.4 25.5 5.29 47.8 24.6 5.85 45.1 23.6 6.46 42.4 22.6 7.11  
50.6 34.6 4.17 48.4 33.7 4.65 46.0 32.7 5.17 43.6 31.8 5.72 41.2 30.8 6.31 38.6 29.8 6.94  
46.2 41.7 4.08 44.0 40.7 4.55 41.9 39.6 5.05 39.8 38.4 5.60 37.5 37.0 6.18 35.2 35.2 6.79  
44.1 44.1 4.04 42.5 42.5 4.52 40.8 40.8 5.03 39.1 39.1 5.57 37.2 37.2 6.17 35.2 35.2 6.79  
72  
67  
62  
57  
56.2 28.4 4.37 53.7 27.5 4.85 51.1 26.5 5.38 48.4 25.6 5.96 45.6 24.6 6.56 42.8 23.6 7.21  
51.5 36.4 4.27 49.1 35.5 4.74 46.7 34.5 5.26 44.2 33.5 5.82 41.6 32.5 6.41 39.0 31.5 7.04  
46.9 44.0 4.17 44.8 42.8 4.64 42.6 41.6 5.15 40.4 40.2 5.70 38.3 38.3 6.29 36.2 36.2 6.92  
45.5 45.5 4.15 43.8 43.8 4.62 42.0 42.0 5.14 40.2 40.2 5.69 38.3 38.3 6.29 36.2 36.2 6.92  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Unit  
Size  
Indoor  
Unit  
Size  
Section  
Capacity  
1.00  
1.00  
0.98  
1.00  
1.03  
1.01  
1.04  
1.00  
1.00  
1.00  
1.00  
1.00  
0.97  
1.00  
1.03  
1.02  
1.04  
1.07  
1.07  
1.02  
1.03  
1.05  
1.05  
1.00  
1.02  
1.04  
Power  
1.00  
1.00  
0.99  
1.00  
1.01  
1.00  
1.01  
0.99  
1.00  
1.01  
1.00  
1.01  
0.98  
1.00  
1.01  
1.02  
1.04  
1.03  
1.01  
1.02  
1.03  
1.02  
1.02  
1.00  
1.01  
1.03  
Section  
Capacity  
0.99  
Power  
1.00  
1.00  
1.01  
1.01  
0.94  
0.95  
0.94  
0.94  
0.95  
CD5AA  
048  
060  
048  
048  
060  
048  
060  
048  
048  
060  
048  
060  
048  
048  
060  
048  
060  
070  
006  
048  
060  
054  
070  
048  
060  
005  
CD5AA  
CD5AC  
CE3AA  
048  
048  
048  
060  
048  
060  
060  
048  
060  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
0.99  
0.99  
1.00  
CK3BA  
0.99  
CE3AA  
0.99  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BX  
0.99  
CF5AA  
CK3BA  
0.99  
1.00  
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE  
CK5A/CK5BA  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
060  
048  
048  
060  
048  
048  
060  
048  
060  
060  
048  
060  
0.99  
0.99  
0.99  
1.00  
0.99  
0.99  
1.00  
0.99  
0.99  
0.99  
0.99  
1.00  
1.02  
1.01  
1.01  
1.02  
1.01  
1.02  
1.02  
0.95  
0.95  
0.95  
0.95  
0.95  
CK5A/CK5BN  
CK5A/CK5BW  
CK5A/CK5BX  
F(A,B)4AN(F,B)  
CD5AA  
CE3AA  
FB4ANB  
FB4CNF  
CK3BA  
FC4BN(F,B)  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BX  
FC4BNB  
FG3AA  
COILS + 355MAV042040 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
060  
048  
048  
060  
0.99  
0.99  
0.99  
1.00  
0.99  
0.98  
0.98  
0.99  
FK4CNF  
COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
060  
048  
048  
060  
048  
048  
060  
048  
060  
048  
0.99  
0.99  
0.99  
1.00  
0.99  
0.99  
1.00  
0.99  
0.99  
0.99  
1.02  
1.02  
1.02  
1.03  
1.02  
1.03  
1.03  
0.97  
0.97  
0.97  
COILS + 355MAV042060 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
060  
048  
048  
060  
0.99  
0.99  
0.99  
1.00  
0.99  
0.98  
0.98  
0.99  
CD5A/CD5BA  
CE3AA  
COILS + 355MAV042080 VARIABLE-SPEED FURNACE  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
060  
048  
048  
060  
048  
060  
048  
1.00  
0.99  
0.99  
1.01  
0.99  
0.99  
0.99  
0.97  
0.96  
0.96  
0.97  
0.97  
0.98  
0.97  
CK3BA  
CK5A/CK5BA  
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE  
CK3BA  
CC5A/CD5AA  
CC5A/CD5AW  
060  
048  
060  
0.99  
0.99  
1.00  
1.01  
1.00  
1.01  
CK5A/CK5BA  
See notes on page 24.  
—22—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
1400  
1600  
1800  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C048-A, B, C Outdoor Section With CD5AA048 Indoor Section Continued  
72  
67  
62  
57  
54.3 26.2 4.17 51.9 25.3 4.65 49.5 24.4 5.18 47.0 23.5 5.75 44.4 22.6 6.35 41.8 21.6 6.99  
49.6 32.8 4.07 47.4 31.8 4.55 45.2 30.9 5.06 42.9 30.0 5.61 40.5 29.0 6.21 38.1 28.0 6.83  
45.2 39.2 3.99 43.2 38.2 4.45 41.1 37.2 4.95 39.0 36.1 5.49 36.8 35.0 6.07 34.4 33.6 6.66  
42.4 42.4 3.94 40.9 40.9 4.41 39.3 39.3 4.91 37.7 37.7 5.45 36.0 36.0 6.03 33.9 33.9 6.64  
72  
67  
62  
57  
55.4 27.4 4.28 52.9 26.5 4.76 50.4 25.5 5.29 47.8 24.6 5.85 45.1 23.6 6.46 42.4 22.6 7.11  
50.6 34.6 4.17 48.4 33.7 4.65 46.0 32.7 5.17 43.6 31.8 5.72 41.2 30.8 6.31 38.6 29.8 6.94  
46.2 41.7 4.08 44.0 40.7 4.55 41.9 39.6 5.05 39.8 38.4 5.60 37.5 37.0 6.18 35.2 35.2 6.79  
44.1 44.1 4.04 42.5 42.5 4.52 40.8 40.8 5.03 39.1 39.1 5.57 37.2 37.2 6.17 35.2 35.2 6.79  
72  
67  
62  
57  
56.2 28.4 4.37 53.7 27.5 4.85 51.1 26.5 5.38 48.4 25.6 5.96 45.6 24.6 6.56 42.8 23.6 7.21  
51.5 36.4 4.27 49.1 35.5 4.74 46.7 34.5 5.26 44.2 33.5 5.82 41.6 32.5 6.41 39.0 31.5 7.04  
46.9 44.0 4.17 44.8 42.8 4.64 42.6 41.6 5.15 40.4 40.2 5.70 38.3 38.3 6.29 36.2 36.2 6.92  
45.5 45.5 4.15 43.8 43.8 4.62 42.0 42.0 5.14 40.2 40.2 5.69 38.3 38.3 6.29 36.2 36.2 6.92  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Unit  
Size  
Indoor  
Unit  
Size  
Capacity  
Power  
Section  
Capacity  
0.99  
Power  
0.96  
0.97  
0.96  
0.96  
0.97  
COILS + 355MAV060080 VARIABLE-SPEED FURNACE  
CK3BA  
048  
060  
048  
060  
060  
CK3BA  
048  
060  
048  
060  
060  
0.99  
0.99  
0.99  
0.99  
1.00  
0.98  
0.99  
0.98  
0.98  
0.99  
0.99  
CK5A/CK5BA  
CK5A/CK5BX  
0.99  
CK5A/CK5BA  
CK5A/CK5BX  
0.99  
1.00  
COILS + 355MAV060120 VARIABLE-SPEED FURNACE  
COILS + 355MAV060100 VARIABLE-SPEED FURNACE  
CK3BA  
048  
060  
060  
048  
060  
0.99  
0.99  
0.99  
0.99  
1.00  
0.96  
0.97  
0.96  
0.96  
0.97  
CC5A/CD5AA  
CC5A/CD5AC  
CC5A/CD5AW  
060  
048  
048  
060  
1.00  
0.99  
0.99  
1.01  
0.97  
0.96  
0.96  
0.97  
CK5A/CK5BA  
CK5A/CK5BW  
CK5A/CK5BX  
See notes on page 24.  
—23—  
DETAILED COOLING CAPACITIES* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
EVAPORATOR  
AIR  
75  
85  
95  
105  
Capacity  
MBtuh†  
115  
Capacity  
MBtuh†  
125  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Capacity  
MBtuh†  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
Total  
Sys  
CFM  
1750  
1800  
2100  
2250  
EWB  
Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW** Total Sens‡ KW**  
561C060-A, B, E Outdoor Section With CC5A/CD5AW060 Indoor Section  
72  
67  
62  
57  
66.3 32.0 5.14 63.7 31.0 5.64 61.0 30.0 6.20 58.1 28.9 6.82 55.0 27.8 7.50 51.7 26.6 8.24  
60.6 40.0 4.96 58.1 38.9 5.46 55.6 37.9 6.01 52.9 36.7 6.63 50.0 35.6 7.30 47.1 34.4 8.02  
55.2 47.8 4.81 52.9 46.7 5.30 50.6 45.5 5.85 48.1 44.3 6.46 45.4 42.9 7.12 42.8 41.5 7.80  
51.8 51.8 4.72 50.0 50.0 5.22 48.2 48.2 5.78 46.3 46.3 6.40 44.2 44.2 7.07 42.1 42.1 7.77  
72  
67  
62  
57  
66.6 32.3 5.17 64.0 31.3 5.67 61.2 30.3 6.23 58.3 29.2 6.85 55.2 28.1 7.53 51.9 26.9 8.27  
60.8 40.4 4.99 58.4 39.4 5.48 55.8 38.3 6.04 53.1 37.2 6.65 50.2 36.0 7.33 47.2 34.8 8.05  
55.5 48.4 4.83 53.2 47.3 5.33 50.8 46.1 5.88 48.2 44.8 6.49 45.6 43.5 7.14 42.9 42.0 7.83  
52.2 52.2 4.75 50.4 50.4 5.25 48.6 48.6 5.81 46.6 46.6 6.43 44.5 44.5 7.11 42.4 42.4 7.81  
72  
67  
62  
57  
68.1 33.9 5.34 65.3 32.9 5.83 62.4 31.8 6.39 59.4 30.7 7.01 56.1 29.6 7.69 52.8 28.4 8.43  
62.2 43.1 5.14 59.7 42.1 5.64 57.0 41.0 6.20 54.2 39.8 6.81 51.2 38.6 7.48 48.0 37.4 8.21  
56.7 52.0 4.98 54.4 50.8 5.48 51.9 49.5 6.03 49.3 48.0 6.64 46.6 46.3 7.30 44.1 44.1 8.01  
54.6 54.6 4.93 52.7 52.7 5.43 50.7 50.7 5.99 48.6 48.6 6.62 46.4 46.4 7.29 44.1 44.1 8.01  
72  
67  
62  
57  
68.7 34.6 5.41 65.9 33.6 5.91 62.9 32.6 6.47 59.8 31.4 7.09 56.5 30.3 7.77 53.1 29.1 8.51  
62.8 44.4 5.22 60.2 43.4 5.71 57.5 42.3 6.27 54.6 41.1 6.89 51.5 39.9 7.56 48.3 38.6 8.28  
57.3 53.7 5.05 54.9 52.4 5.55 52.4 51.0 6.10 49.8 49.3 6.71 47.2 47.2 7.38 44.8 44.8 8.11  
55.6 55.6 5.01 53.7 53.7 5.51 51.6 51.6 6.08 49.5 49.5 6.70 47.2 47.2 7.38 44.8 44.8 8.11  
Multipliers for Determining the Performance With Other Indoor Sections  
Cooling  
Cooling  
Indoor  
Section  
Unit  
Size  
Indoor  
Unit  
Size  
Capacity  
1.00  
0.96  
1.01  
0.96  
0.96  
0.96  
1.00  
1.01  
1.02  
1.00  
1.02  
Power  
1.00  
0.97  
0.99  
1.00  
0.97  
0.98  
1.00  
1.05  
1.03  
1.04  
1.02  
Section  
Capacity  
0.99  
Power  
1.00  
CC5A/CD5AW  
CC5A/CD5AA  
CE3AA  
060  
060  
060  
060  
060  
060  
060  
060  
070  
060  
070  
FG3AAA  
FK4CNB  
060  
006  
1.02  
1.00  
COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE  
CK3BA  
CK3BA  
060  
060  
060  
0.96  
0.96  
1.00  
0.95  
0.95  
0.95  
CK5A/CK5BA  
CK5A/CK5BN  
CK5A/CK5BX  
F(A,B)4AN(F,B)  
FB4ANB  
CK5A/CK5BA  
CK5A/CK5BX  
COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE  
CK3BA  
060  
060  
060  
0.96  
0.96  
0.96  
0.96  
0.96  
0.96  
CK5A/CK5BA  
CK5A/CK5BX  
FC4BN(F,B)  
FC4BNB  
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or  
indoor unit is located above outdoor unit, a slight variation in capacity may occur.  
Total and sensible capacities are net capacities. Blower motor heat has been subtracted.  
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh  
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air  
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.  
** Unit kw is total of indoor and outdoor unit kilowatts.  
EWB—Entering Wet Bulb  
—24—  
CONDENSER ONLY RATINGS*  
CONDENSER ENTERING AIR TEMPERATURES °F  
SST  
°F  
55  
65  
75  
85  
95  
105  
115  
125  
561C018-A, D  
TCG  
KW  
17.6  
1.37  
75.6  
16.2  
1.49  
86.1  
14.7  
1.58  
96.4  
13.4  
12.0  
1.73  
10.7  
1.77  
9.52  
1.80  
8.35  
1.82  
30  
35  
40  
45  
50  
55  
1.66  
SDT  
106.0  
116.0  
126.0  
136.0  
146.0  
TCG  
KW  
SDT  
19.6  
1.40  
76.5  
18.1  
1.52  
87.2  
16.6  
1.63  
97.4  
15.1  
1.73  
107.0  
13.6  
1.81  
117.0  
12.3  
1.87  
127.0  
10.9  
1.91  
137.0  
9.68  
1.93  
146.0  
TCG  
KW  
SDT  
21.8  
1.42  
77.6  
20.1  
1.56  
88.4  
18.5  
1.68  
98.6  
16.9  
1.79  
109.0  
15.4  
1.88  
119.0  
13.9  
1.96  
128.0  
12.5  
2.01  
138.0  
11.1  
2.05  
147.0  
TCG  
KW  
SDT  
24.1  
1.44  
78.7  
22.3  
1.59  
89.7  
20.6  
1.73  
100.0  
18.9  
1.85  
110.0  
17.2  
1.96  
120.0  
15.6  
2.05  
130.0  
14.1  
2.12  
139.0  
12.6  
2.17  
149.0  
TCG  
KW  
SDT  
26.5  
1.46  
79.8  
24.6  
1.62  
91.0  
22.7  
1.77  
102.0  
20.9  
1.91  
112.0  
19.1  
2.03  
122.0  
17.4  
2.14  
131.0  
15.8  
2.22  
141.0  
14.2  
2.29  
150.0  
TCG  
KW  
SDT  
29.0  
1.47  
81.1  
27.0  
1.65  
92.3  
25.0  
1.82  
103.0  
23.1  
1.97  
113.0  
21.2  
2.10  
123.0  
19.4  
2.22  
133.0  
17.6  
2.32  
142.0  
15.9  
2.40  
152.0  
561C024-A, D  
TCG  
KW  
22.5  
1.83  
70.0  
20.9  
1.95  
82.2  
19.2  
2.05  
93.6  
17.5  
15.9  
2.21  
14.2  
2.26  
12.6  
2.29  
11.0  
2.29  
30  
35  
40  
45  
50  
55  
2.14  
SDT  
104.0  
115.0  
125.0  
135.0  
145.0  
TCG  
KW  
SDT  
24.9  
1.89  
69.8  
23.2  
2.01  
82.6  
21.5  
2.13  
94.2  
19.7  
2.23  
105.0  
17.9  
2.32  
116.0  
16.2  
2.38  
126.0  
14.5  
2.43  
136.0  
12.8  
2.45  
145.0  
TCG  
KW  
SDT  
27.5  
1.94  
69.5  
25.7  
2.08  
82.9  
23.8  
2.21  
95.0  
22.0  
2.32  
106.0  
20.1  
2.42  
117.0  
18.3  
2.50  
127.0  
16.5  
2.57  
137.0  
14.6  
2.60  
146.0  
TCG  
KW  
SDT  
30.1  
2.00  
69.7  
28.3  
2.15  
83.2  
26.3  
2.29  
95.6  
24.4  
2.42  
107.0  
22.4  
2.53  
118.0  
20.5  
2.63  
128.0  
18.5  
2.70  
138.0  
16.6  
2.76  
148.0  
TCG  
KW  
SDT  
32.9  
2.07  
70.3  
31.0  
2.22  
83.4  
29.0  
2.37  
96.3  
26.9  
2.51  
108.0  
24.8  
2.64  
119.0  
22.7  
2.75  
129.0  
20.7  
2.84  
139.0  
18.7  
2.91  
149.0  
TCG  
KW  
SDT  
35.8  
2.13  
70.9  
33.8  
2.29  
83.8  
31.8  
2.45  
97.0  
29.6  
2.60  
109.0  
27.3  
2.74  
120.0  
25.1  
2.87  
131.0  
23.0  
2.98  
141.0  
20.9  
3.07  
151.0  
561C030-A, D  
TCG  
KW  
28.0  
2.21  
77.5  
26.0  
2.35  
87.5  
24.0  
2.48  
97.4  
22.0  
20.1  
2.72  
18.2  
2.82  
16.4  
2.91  
14.7  
2.98  
30  
35  
40  
45  
50  
55  
2.61  
SDT  
107.0  
117.0  
127.0  
136.0  
146.0  
TCG  
KW  
SDT  
31.1  
2.29  
78.9  
28.9  
2.44  
88.9  
26.7  
2.59  
98.8  
24.6  
2.72  
109.0  
22.6  
2.85  
118.0  
20.6  
2.97  
128.0  
18.6  
3.07  
137.0  
16.8  
3.15  
147.0  
TCG  
KW  
SDT  
34.3  
2.38  
80.5  
32.0  
2.54  
90.6  
29.7  
2.70  
100.0  
27.4  
2.85  
110.0  
25.2  
2.99  
120.0  
23.1  
3.11  
129.0  
21.0  
3.23  
139.0  
18.9  
3.33  
148.0  
TCG  
KW  
SDT  
37.7  
2.47  
82.1  
35.2  
2.64  
92.3  
32.8  
2.81  
102.0  
30.4  
2.97  
112.0  
28.0  
3.12  
121.0  
25.7  
3.27  
131.0  
23.4  
3.40  
140.0  
21.2  
3.51  
150.0  
TCG  
KW  
SDT  
41.3  
2.56  
83.9  
38.7  
2.75  
94.0  
36.1  
2.92  
104.0  
33.5  
3.10  
114.0  
31.0  
3.27  
123.0  
28.5  
3.42  
133.0  
26.1  
3.57  
142.0  
23.7  
3.70  
151.0  
TCG  
KW  
SDT  
45.1  
2.66  
85.8  
42.3  
2.86  
96.0  
39.5  
3.05  
106.0  
36.8  
3.23  
116.0  
34.1  
3.41  
125.0  
31.4  
3.58  
135.0  
28.8  
3.74  
144.0  
26.3  
3.89  
153.0  
561C036-A, B, D, E  
TCG  
KW  
32.1  
2.33  
78.6  
30.5  
2.57  
89.0  
28.9  
2.84  
99.3  
27.2  
25.5  
3.40  
23.7  
3.68  
21.8  
3.95  
19.9  
4.21  
30  
35  
40  
45  
50  
55  
3.11  
SDT  
109.0  
120.0  
129.0  
139.0  
149.0  
TCG  
KW  
SDT  
35.2  
2.40  
79.9  
33.5  
2.65  
90.4  
31.8  
2.92  
101.0  
30.0  
3.21  
111.0  
28.2  
3.51  
121.0  
26.3  
3.81  
131.0  
24.3  
4.10  
141.0  
22.3  
4.39  
150.0  
TCG  
KW  
SDT  
38.4  
2.47  
81.3  
36.7  
2.72  
91.9  
34.9  
3.00  
102.0  
33.0  
3.30  
112.0  
31.0  
3.61  
123.0  
29.0  
3.93  
132.0  
26.9  
4.25  
142.0  
24.8  
4.56  
152.0  
TCG  
KW  
SDT  
41.8  
2.55  
82.9  
40.0  
2.81  
93.5  
38.1  
3.10  
104.0  
36.1  
3.40  
114.0  
34.0  
3.73  
124.0  
31.8  
4.06  
134.0  
29.7  
4.40  
144.0  
27.4  
4.74  
154.0  
TCG  
KW  
SDT  
45.4  
2.63  
84.6  
43.5  
2.90  
95.3  
41.5  
3.19  
106.0  
39.3  
3.51  
116.0  
37.1  
3.84  
126.0  
34.9  
4.20  
136.0  
32.5  
4.55  
146.0  
30.2  
4.91  
155.0  
TCG  
KW  
SDT  
49.2  
2.72  
86.4  
47.2  
2.99  
97.0  
45.0  
3.29  
107.0  
42.8  
3.62  
118.0  
40.4  
3.97  
128.0  
38.0  
4.33  
138.0  
35.5  
4.70  
148.0  
33.0  
5.08  
157.0  
See notes on page 26.  
—25—  
CONDENSER ONLY RATINGS* Continued  
CONDENSER ENTERING AIR TEMPERATURES °F  
SST  
°F  
55  
65  
75  
85  
95  
105  
115  
125  
561C042-A, B, C  
TCG  
KW  
37.9  
2.73  
80.8  
36.1  
3.03  
91.0  
34.2  
32.1  
30.0  
4.01  
27.8  
4.35  
25.6  
4.68  
23.3  
4.98  
30  
35  
40  
45  
50  
55  
3.34  
3.67  
SDT  
101.0  
111.0  
121.0  
131.0  
141.0  
150.0  
TCG  
KW  
SDT  
41.5  
2.82  
82.5  
39.6  
3.12  
92.7  
37.5  
3.45  
103.0  
35.4  
3.79  
113.0  
33.2  
4.15  
123.0  
30.9  
4.51  
133.0  
28.5  
4.87  
142.0  
26.0  
5.21  
152.0  
TCG  
KW  
SDT  
45.3  
2.91  
84.3  
43.3  
3.22  
94.5  
41.1  
3.56  
105.0  
38.9  
3.92  
115.0  
36.5  
4.29  
125.0  
34.1  
4.67  
134.0  
31.5  
5.06  
144.0  
28.9  
5.43  
154.0  
TCG  
KW  
SDT  
49.4  
3.01  
86.3  
47.2  
3.33  
96.5  
44.9  
3.68  
107.0  
42.5  
4.05  
117.0  
40.0  
4.44  
127.0  
37.4  
4.84  
136.0  
34.8  
5.25  
146.0  
32.0  
5.65  
156.0  
TCG  
KW  
SDT  
53.6  
3.11  
88.3  
51.2  
3.44  
98.5  
48.8  
3.80  
109.0  
46.3  
4.18  
119.0  
43.6  
4.59  
129.0  
40.9  
5.01  
138.0  
38.1  
5.44  
148.0  
35.2  
5.87  
158.0  
TCG  
KW  
SDT  
58.0  
3.22  
90.4  
55.5  
3.56  
101.0  
52.9  
3.93  
111.0  
50.2  
4.32  
121.0  
47.5  
4.74  
131.0  
44.6  
5.18  
140.0  
41.6  
5.63  
150.0  
38.5  
6.09  
160.0  
561C048-A, B, C  
TCG  
KW  
42.6  
3.22  
76.5  
40.8  
3.56  
87.0  
38.9  
3.93  
97.4  
36.9  
34.8  
4.80  
32.7  
5.28  
30.5  
5.79  
28.3  
6.31  
30  
35  
40  
45  
50  
55  
4.34  
SDT  
108.0  
118.0  
128.0  
138.0  
148.0  
TCG  
KW  
SDT  
46.6  
3.28  
77.7  
44.7  
3.61  
88.2  
42.7  
3.99  
98.6  
40.6  
4.41  
109.0  
38.4  
4.87  
119.0  
36.1  
5.37  
129.0  
33.8  
5.89  
139.0  
31.4  
6.44  
149.0  
TCG  
KW  
SDT  
50.9  
3.34  
79.0  
48.8  
3.68  
89.6  
46.7  
4.06  
99.9  
44.4  
4.49  
110.0  
42.1  
4.95  
120.0  
39.7  
5.46  
131.0  
37.2  
6.00  
141.0  
34.7  
6.57  
150.0  
TCG  
KW  
SDT  
55.4  
3.42  
80.4  
53.2  
3.75  
91.0  
50.9  
4.14  
101.0  
48.5  
4.57  
112.0  
46.0  
5.04  
122.0  
43.4  
5.56  
132.0  
40.8  
6.11  
142.0  
38.1  
6.70  
152.0  
TCG  
KW  
SDT  
60.1  
3.49  
81.8  
57.8  
3.84  
92.5  
55.3  
4.22  
103.0  
52.8  
4.66  
113.0  
50.1  
5.13  
124.0  
47.4  
5.66  
134.0  
44.5  
6.23  
144.0  
41.7  
6.83  
154.0  
TCG  
KW  
SDT  
65.1  
3.58  
83.4  
62.6  
3.93  
94.1  
60.0  
4.32  
105.0  
57.3  
4.75  
115.0  
54.5  
5.24  
125.0  
51.5  
5.77  
135.0  
48.5  
6.34  
145.0  
45.4  
6.96  
155.0  
561C060-A, B, E  
TCG  
KW  
52.8  
3.87  
75.7  
50.6  
4.27  
86.2  
48.2  
4.73  
96.6  
45.8  
43.3  
5.78  
40.6  
6.37  
37.9  
6.99  
35.2  
7.63  
30  
35  
40  
45  
50  
55  
5.23  
SDT  
107.0  
117.0  
127.0  
137.0  
147.0  
TCG  
KW  
SDT  
57.8  
3.94  
76.9  
55.4  
4.35  
87.5  
52.9  
4.81  
97.9  
50.3  
5.32  
108.0  
47.6  
5.87  
118.0  
44.8  
6.48  
129.0  
41.9  
7.12  
139.0  
39.0  
7.79  
148.0  
TCG  
KW  
SDT  
63.0  
4.02  
78.2  
60.5  
4.44  
88.9  
57.8  
4.90  
99.3  
55.1  
5.41  
110.0  
52.2  
5.98  
120.0  
49.2  
6.60  
130.0  
46.1  
7.27  
140.0  
43.0  
7.95  
150.0  
TCG  
KW  
SDT  
68.6  
4.12  
79.6  
65.8  
4.53  
90.3  
63.0  
5.00  
101.0  
60.0  
5.52  
111.0  
57.0  
6.09  
121.0  
53.8  
6.72  
132.0  
50.5  
7.41  
142.0  
47.2  
8.12  
152.0  
TCG  
KW  
SDT  
74.4  
4.22  
81.1  
71.5  
4.64  
91.9  
68.5  
5.11  
102.0  
65.3  
5.63  
113.0  
62.1  
6.22  
123.0  
58.7  
6.86  
133.0  
55.2  
7.55  
143.0  
51.5  
8.29  
153.0  
TCG  
KW  
SDT  
80.5  
4.33  
82.7  
77.4  
4.75  
93.6  
74.2  
5.23  
104.0  
70.9  
5.76  
115.0  
67.4  
6.35  
125.0  
63.8  
7.00  
135.0  
60.1  
7.70  
145.0  
56.2  
8.46  
155.0  
* ARI listing applies only to systems shown in Ratings and Performance table.  
KW Total Power (Kw)  
SDT — Saturated Temperature Leaving Compressor (°F)  
SST — Saturated Temperature Entering Compressor (°F)  
TCG — Gross Cooling Capacity (1000 Btuh)  
—26—  
SYSTEM DESIGN  
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.  
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).  
3. Maximum outdoor operating air temperature is 125°F (51.7°C).  
4. For reliable operation, unit should be level in all horizontal planes.  
5. Maximum elevation of indoor coil above or below base of outdoor unit is: indoor coil above = 50 ft, indoor coil below = 150 ft.  
6. For interconnecting refrigerant tube lengths between 50 and 175 ft, consult Residential Split Systems Long-Line Application Guideline available  
from equipment distributor.  
7. Crankcase heater required when interconnecting refrigerant tube length exceeds 50 ft.  
8. If any refrigerant tubing is buried, provide a 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. may be  
buried without further consideration. For buried lines longer than 3 ft, consult your local distributor.  
9. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.  
—27—  
Air-Cooled, Split-System  
Air Conditioner  
GUIDE SPECIFICATIONS  
561C  
1-1/2 to 5 Tons Nominal  
GENERAL  
Condenser fan motors will be totally enclosed, 1-phase type  
with class B insulation and permanently lubricated bearings.  
System Description  
Outdoor-mounted, air-cooled, split-system air conditioner unit  
suitable for ground or rooftop installation. Unit consists of a her-  
metic compressor, an air-cooled coil, propeller-type condenser  
fan, and a control box. Unit will discharge supply air upward as  
shown on contract drawings. Unit will be used in a refrigeration  
circuit to match up to a packaged fan coil or coil unit.  
Shafts will be corrosion resistant.  
Fan blades will be statically and dynamically balanced.  
Condenser fan openings will be equipped with PVC-coated  
steel wire safety guards.  
Compressor  
Compressor will be hermetically sealed.  
Compressor will be mounted on rubber vibration isolators.  
Condenser Coil  
Quality Assurance  
Unit will be rated in accordance with the latest edition of ARI  
Standard 210.  
Condenser coil will be air cooled.  
Unit will be certified for capacity, efficiency, and listed in the lat-  
est ARI directory.  
Coil will be constructed of aluminum fins mechanically bonded  
to copper tubes which are then cleaned, dehydrated, and  
sealed.  
Unit construction will comply with latest edition of ANSI/  
ASHRAE and with NEC.  
Refrigeration Components  
Unit will be constructed in accordance with UL standards and  
will carry the UL label of approval. Unit will have c-UL approval.  
Refrigeration circuit components will include liquid line shutoff  
valve with sweat connections, suction line shutoff valves with  
sweat connections, system charge of R22 refrigerant, and com-  
pressor oil.  
Unit cabinet will be capable of withstanding Federal Test  
Method Standard No. 141 (Method 6061) 500-hr salt spray test.  
Air-cooled condenser coils will be leak tested at 150 psig and  
pressure tested at 300 psig.  
Operating Characteristics  
The capacity of the unit will meet or exceed _____ Btuh at a  
suction temperature of _____ °F. The power consumption at full  
load will not exceed _____ kw.  
Unit constructed in ISO 9001 approved facility.  
Delivery, Storage, and Handling  
Unit will be shipped as single package only and is stored and  
handled per unit manufacturer’s recommendations.  
Combination of the unit and the evaporator or fan coil unit will  
have a total net cooling capacity of _____ Btuh or greater at  
conditions of _____ CFM entering air temperature at the evapo-  
rator at _____ °F wet bulb and _____ °F dry bulb, and air enter-  
ing the unit at _____ °F.  
Warranty (for inclusion by specifying engineer)  
U.S. and Canada only.  
PRODUCTS  
The system will have an SEER of _____ Btuh/watt or greater at  
DOE conditions.  
Equipment  
Factory-assembled, single-piece, air-cooled air conditioner unit.  
Contained within the unit enclosure will be all factory wiring, pip-  
ing, controls, compressor, refrigerant charge (R22), and special  
features required prior to field start-up.  
Electrical Requirements  
Nominal unit electrical characteristics will be _____ v, single  
phase, 60 hertz. The unit will be capable of satisfactory opera-  
tion within voltage limits of _____ v to _____ v.  
Unit Cabinet  
Unit electrical power will be single point connection.  
Control circuit will be 24v.  
Unit cabinet will be constructed of galvanized steel, bonderized,  
and coated with a powder coat paint.  
Fans  
Special Features  
Condenser fan will be direct-drive propeller type, discharging air  
upward.  
Refer to section of this literature identifying accessories and  
descriptions for specific features and available enhancements.  
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE  
UNIT MUST BE INSTALLED IN ACCORDANCE  
WITH INSTALLATION INSTRUCTIONS  
Cancels PDS 561C.18.5  
© 1999 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231  
PRINTED IN U.S.A.  
Catalog No. 5256-108 11-99  
—28—  

AGFA 1 User Manual
Bunn Beverage Dispenser TDS5 User Manual
Bunn Silver Series 2 Flavour User Manual
Carrier PREMIERLINK 33CSPREMLK User Manual
Danby DAC6006DE User Manual
Friedrich C24YF User Manual
Fujitsu All in One Printer B19W 5 ECO User Manual
Haier HSU 09R04 HSU 12R04 HSU 18R04 HSU 24R04 User Manual
Honeywell ML6421 User Manual
HP Hewlett Packard Hp Scanjet Enterprise Flow 7000 S2 Sheet Feed Scanner 7000N User Manual