INTRODUCTION  
This equipment dispenses hot beverages or soups on demand from powered product. It is for indoor use only  
on a sturdy counter or shelf.  
USER NOTICES  
Carefully read and follow all notices on the equipment and in this manual. They were written for your protection.  
All notices are to be kept in good condition. Replace any unreadable or damaged labels.  
CONTROL THERMOSTAT ADJUSTMENT  
180F  
200F  
190F  
00824.0002  
APPROXIMATE THERMOSTAT TEMPERATURE SETTINGS  
28368.0003A 08/08  
©
2008 BUNN-O-MATIC CORPORATION  
28368.0003  
00831.0000  
As directed in the International Plumbing Code of the  
International Code Council and the Food Code  
Manual of the Food and Drug Administration (FDA),  
this equipment must be installed with adequate  
backflow prevention to comply with federal, state  
and local codes. For models installed outside the  
U.S.A., you must comply with the applicable Plumb-  
ing /Sanitation Code for your area.  
37881.0000  
00656.0001  
27096.0000 FMD-1 ONLY  
FMD-2 28328.0005  
FMD-1 28328.0004  
28964.0000  
28964.0001  
29112 051111  
3
INITIAL SET-UP  
1. Locate the drip tray assembly beneath the dispenser nested in the packing material.  
2. Remove the drip tray and the drip tray cover and set them aside.  
3. Remove the water strainer assembly from the drip tray and set it aside.  
4. Remove the four legs from the packaging material, apply non-skid pads to the bottom of the legs and se-  
curely install the legs in the dispenser base.  
CE REQUIREMENTS  
• This appliance must be installed in locations where it can be overseen by trained personnel.  
• For proper operation, this appliance must be installed where the temperature is between 5°C to 35°C.  
• Appliance shall not be tilted more than 10° for safe operation.  
• An electrician must provide electrical service as specified in conformance with all local and national codes.  
• This appliance must not be cleaned by water jet.  
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental  
capabilities, or lack of experience and knowledge, unless they have been given instructions concerning use of  
this appliance by a person responsible for its safety.  
• Children should be supervised to ensure they do not play with the appliance.  
If the power cord is ever damaged, it must be replaced by the manufacturer or authorized service personnel with  
a special cord available from the manufacturer or its authorized service personnel in order to avoid a hazard.  
• Machine must not be immersed for cleaning.  
ELECTRICAL REQUIREMENTS  
CAUTION - The dispenser must be disconnected from the power source until specified in Initial Set-Up.  
The 120 volt version of this dispenser has an attached cordset and requires 2-wire, grounded service rated 120  
volts ac, 15 amp, single phase, 60 Hz. The mating connector must be a NEMA 5-15R.  
The 120/208 and the 120/240 versions of this dispenser has an attched cordset. The mating connector must be  
a NEMA 14-20R.  
The 220-240 volt version of this dispenser has an attached cordset.  
Refer to the dispenser’s dataplate and local/national electrical codes for exact voltage requirement.  
ELECTRICAL HOOk-UP  
CAUTION – Improper electrical installation will damage electronic components.  
1. An electrician must provide electrical service as specified.  
2. Using a voltmeter, check the voltage and color coding of each conductor at the electrical source.  
3. Open the front door of the dispenser and place the heater switch in the “OFF” (upper position).  
4. Connect the dispenser to the power source.  
5. If plumbing is to be hooked-up later be sure the dispenser is disconnected from the power source. If plumb-  
ing has been hooked-up, the dispenser is ready for Initial Fill & Heat.  
29112 011510  
4
PLUMBING REQUIREMENTS  
This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 90  
psi (138 and 620 kPa) from a 12” or larger supply line. A shut-off valve should be installed in the line before the  
dispenser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi  
(345 kPa). The water inlet fitting is 14” flare.  
NOTE - Bunn-O-Matic recommends 14” copper tubing for installations of less than 25 feet and 38” for more than  
25 feet from the 12” water supply line. At least 18 inches of an FDA approved flexible beverage tubing, such as  
reinforced braided polyethylene or silicone, before the brewer will facilitate movement to clean the countertop.  
Bunn-O-Matic does not recommend the use of a saddle valve to install the brewer. The size and shape of the  
hole made in the supply line by this type of device may restrict water flow.  
As directed in the International Plumbing Code of the International Code Council and the Food Code  
Manual of the Food and Drug Administration (FDA), this equipment must be installed with adequate  
backflow prevention to comply with federal, state and local codes. For models installed outside the  
U.S.A., you must comply with the applicable Plumbing /Sanitation Code for your area.  
PLUMBING HOOk-UP (Early Models)  
1. Securely attach the short piece of tubing on the water strainer assembly to the inlet fitting on the bottom of  
the dispenser.  
2. Flush the water line and securely attach it to the flare fitting on the water strainer assembly.  
3. Turn-on the water supply.  
PLUMBING HOOk-UP (Late Models)  
1. Flush the water line and securely attach it to the elbow fitting on the bottom of the dispenser.  
2. Turn-on the water supply.  
NOTE - Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed  
and maintained in accordance with federal, state and local codes.  
PRESET TANk TEMPERATURE  
Tank temperatures have been preset at the factory to 180°F (82°C). Bunn recommends that to provide the best  
quality beverage, the installer adjust the tank temperature to the powder product manufacturer’s recommended  
temperature for the hot powder product being used.  
INITIAL FILL & HEAT  
CAUTION - The dispenser must be disconnected from the power source throughout the initial set-up, except  
when specified in the instructions.  
1. Turn-on the water supply and connect the dispenser to the power source.  
2. Water will automatically flow into the tank to the proper level and then shut-off. This will take less than five  
minutes.  
3. When the tank is full of water, open the front door and place the heater switch in the “ON” (lower) position.  
A tank full of cold water will take approximately forty minutes for the water to heat on 120 volt versions or  
twenty minutes for 120/208 volt versions, 120/240 volt versions and 220-240 volt versions.  
During this waiting period, complete these dispenser set-up steps:  
a. Place the drip tray in front of the dispenser. Set the drip tray cover in place.  
b. Place a set of keyholes in the cup locator plate over the screws beneath the hopper access door and push  
down gently.  
c. Fill the hopper with the dry product to be dispensed.  
29112 010413  
5
LIQUID LEVEL CONTROL  
The system automatically maintains the hot water tank’s level by energizing the refill solenoid when the water  
level drops below the liquid level probe. If the system for the FMD-2 only has not successfully refilled in 7 1/2  
minutes, a refill error occurs.  
When a refill error occurs, the refill solenoid is de-energized and the rinse L.E.D. will flash about once every  
5 seconds.  
Once the cause of the refill error has been investigated (see the troubleshooting guide in the Operating and  
Service Manual) and cured, the system can be reset by disconnecting (for at least 5 seconds) and then recon-  
necting the power to the machine.  
RINSE TIMER (FMD-2 ONLY)  
The dispenser is shipped from the factory with the rinse timer disabled. To enable the rinse timer, remove  
power from the dispenser, remove the lower access panel, and remove the jumper from J1 of the control board.  
Replace the lower access panel, and return power to the dispenser.  
When enabled, the rinse timer automatically keeps track of the time since the dispenser was last run through  
a rinse sequence. If the dispenser detects that a rinse sequence has not been run for 8 hours, the rinse L.E.D.  
will flash continually. If, after an additional 4 hours (12 hours total), a rinse sequence has still not been run, the  
rinse L.E.D. will light continuously, and the hopper drives will be disabled until a rinse sequence has been run.  
RUNNING A RINSE SEQUENCE  
1. Place the rinse/run switch in the rinse position.  
2. Sequentially, or simultaneously, at each of the two positions (FMD-2 only) dispense for at least 10 seconds.  
3. After the rinse L.E.D. has extinguished, the rinse timer is reset (FMD-2 only).  
4. Return the rinse/run switch to the run position.  
DISPENSER USE  
1. Simply place a cup on the drip tray beneath the dispensing tip.  
2. Press the button to froth and dispense the beverage.  
3. Release the button when the cup is approximately 2/3 full and allow the mixing chamber to drain.  
NOTE - The mixing chamber must drain at the end of each dispense.  
COLD BEVERAGE SET-UP (OPTIONAL FMD-2 ONLY)  
Cold beverages may be dispensed from the left dispense position as follows:  
1. Disconnect the dispenser from the power source.  
2. Remove the lower front access panel.  
3. Locate the Hot/Cold jumper connection near the whipper panel in the main wiring harness.  
4. Remove the Hot jumper connection (red jumper plug) from the main wiring harness and connect the Cold  
jumper connection (blue jumper plug) to the main harness.  
5. Replace the lower front access panel and reconnect the dispenser to the power source.  
PREVENTIVE MAINTENANCE  
Bunn-O-Matic® Corporation recommends that preventive maintenance be performed at regular intervals. Maintenance  
should be performed by a qualified service technician. For Technical Service, contact Bunn-O-Matic® Corporation at  
1-800-286-6070.  
NOTE: Replacement parts or service caused by failure to perform required maintenance is not covered by warranty.  
Cycle  
(months)  
6
Item  
Part Number  
32906.0000  
29128.0000  
Mixing Chamber Kit  
Whipper Motor Seal Kit  
Whipper Shaft Seal Kit  
6
3 or as  
needed  
26356.1000  
29112 051111  
6
CLEANING  
The use of a damp cloth rinsed in any mild, non-abrasive, liquid detergent is recommended for cleaning all sur-  
faces on Bunn-O-Matic equipment. Do NOT clean this equipment with a water jet device.  
1 x 24h  
1. Rinse out Whipper Chambers by placing RINSE/RUN  
switch in the "RINSE" position and activating DISPENSE  
switches.  
2. Turn elbow up, remove Hoppers, refill with product and  
replace hoppers into dispenser.  
3. Empty Drip Tray and wash in a solution of dish detergent.  
1. Para limpiar las camaras de mezcla, coloque el interruptor en la  
posicón ENJUAGUE/MARCHA (”RINSE/RUN”) y pulse el boton  
para espumar y distribuir la bebida (”DISPENSE”).  
2. Gire el codo hacia arriba, remueva las tolvas, llene las tolvas con  
producto y coloque las tolvas nuevamente en la maquina.  
3. Vacie la bandeja de goteo y limpiela con un detergente liquido  
suave no abrasivo.  
1 x 7d  
9
1
6
2
8
7
5
3
4
a. Wash  
b. Rinse  
c. Sanitize c. Desinfecte  
d. Dry d. Seque  
a. Lave  
b. Enjuague  
Replace Light Bulbs  
as required.  
Cambie los bombillos  
quemados cuando  
sea necesario.  
a
b
c
NOTICE  
The cleaning instructions noted above are for non-dairy sugar based food products. When dispensing any other food product,  
the cleaning cycle for the whipping chamber assembly and ejector elbow must be performed daily.  
NOTA:  
Las instrucciones de limpieza descritas anteriormente excluyen productos lacteos azucarados. La limpieza de las camaras  
de mezcla y de los codos de salida de cada tolva deberá realizarse diariamente.  
37254.0000A 07/04 © 2004 BUNN-O-MATIC CORPORATION  
29112 060509  
7
ADJUSTMENTS  
The beverage solenoid is preset to dispense approximately one ounce per second. This amount can be adjusted:  
1. Disconnect the dispenser from the power source.  
2. Remove product hopper(s).  
3. Remove the hole plug(s) in the auger motor mounting panel.  
4. Rotate the control at the base of the solenoid clockwise to decrease or counterclockwise to increase the  
amount of water.  
5. Reinstall plug(s) and hopper(s).  
HOPPER MOTOR SPEED ADJUSTMENT (FMD-1)  
The hopper dispense rate is preset at the factory. With 8 tooth gear and auger wire the preset dispense rate is  
approximately 3 to 5 grams per second. With 12 tooth gear and auger wire the preset dispense rate is approxi-  
mately 5 to 7 grams per second. The hopper dispense rate can be adjusted to a range of dispense rates from  
approximately 1.5 to 12 grams per second, as follows:  
1. Set the tank heater switch to the off position.  
2. Open the top front cover of the dispenser and remove the two screws securing the top cover.  
3. Remove the top cover assembly and set it aside.  
4. Locate the motor speed adjuster (leftmost) on the dispenser cabinet top cross member.  
5. Using extreme care not to touch the live terminals of the tank heater, adjust the motor speed by rotating  
the motor speed adjuster to the desired point, ranging from minimum (full counterclockwise) to maximum  
(full clockwise.)  
6. After the motor adjustment is complete, replace the top cover assembly, securing it with the two screws,  
and return the tank heater switch to the on position.  
HOPPER MOTOR SPEED PROGRAMING (FMD-2)  
The hopper dispense rate is preset at the factory. With 22 tooth gear and auger wire the preset dispense rate is  
approximately 3 to 5 grams per second. With 32 tooth gear and auger wire the preset dispense rate is approxi-  
mately 5 to 7 grams per second. The hopper dispense rate can be adjusted to a range of dispense rates from  
approximately 1.5 to 12 grams per second, as follows:  
1. Place the rinse/run switch in the center (program) position.  
2. Place the increase/decrease switch in the desired (increase or decrease) position.  
3. Press and release the dispense switch for the chamber you wish to adjust. Each time the dispense switch  
is pressed, the rinse L.E.D. will flash, and the motor speed for that hopper will be increased/decreased by  
approximately 2 1/2%.  
4. Return the rinse/run switch to the run position after hopper motor speed adjustments are complete.  
DRAINING THE HOT WATER TANk  
CAUTION - The dispenser must be disconnected from the power source throughout these steps.  
1. Disconnect the dispenser from the power source.  
2. Open front door and place tank heater switch in the “OFF” (upper) position.  
3. Shut-off and disconnect the incoming water supply.  
4. Remove the top panel.  
5. Gently remove one of the grommets from the tank lid.  
6. Insert a tube to the bottom of the tank and syphon ALL of the water out.  
NOTE - The dispenser must be refilled using the INITIAL FILL & HEAT steps before reconnecting to the power  
source.  
29112 091307  
8

Brother MFC 295CN User Manual
Energizer CHFM8 User Manual
Epson Stylus TX203 User Manual
Friedrich Air Conditioner SM15 SS12 User Manual
GE ASQ14 User Manual
Goodman Mfg Co LP Air Conditioner SS SSX16 User Manual
Haier HW 12LN03 User Manual
Havis Shields Van Permanent Rear Step KK S ST RP User Manual
Heat Controller Inc Air Conditioner A MMH36FA 1 User Manual
HP Hewlett Packard PHOTOSMART 7200 User Manual