BRK electronic Network Card ADK 12 User Manual

INSTALLATION OF THE  
ADK ADAPTER PLUG  
ELECTRICAL SHOCK HAZARD. Turn off power to the area where you  
will install this unit at the circuit breaker or fuse box before beginning  
installation. Failure to turn off the power before installation may result in  
serious electrical shock, injury or death. Do not restore power until all  
Smoke Alarms are completely installed.  
Installation of this unit must conform to the electrical codes in your  
area; Article 760 of NFPA 70 (NEC), NFPA 72, NFPA 101; SBC (SBCCI);  
UBC (ICBO); NBC (BOCA); OTFDC (CABO), and any other local or  
building codes that may apply. Wiring and installation must be per-  
formed by a licensed electrician. Failure to follow these guidelines  
may result in injury or property damage.  
INSTALLATION INSTRUCTIONS  
This unit must be powered by a 24-hour, 120VAC pure sine wave 60Hz  
circuit. Be sure the circuit cannot be turned off by a switch, dimmer,  
or ground fault circuit interrupter. Failure to connect this unit to a  
24-hour circuit may prevent it from providing constant protection.  
1. Verify which MODELS are installed in your system to determine if they are  
compatible with the ADK Adapter Plug (see part C below).  
2. Turn off AC power.  
3. Remove unit. Remove old mounting bracket.  
4. Install new mounting bracket (see part A below).  
For all other Smoke Alarm information, instructions and warnings, refer to the  
Smoke Alarm User’s Manual.  
5. Connect the black end of the ADK Adapter Plug to the existing power  
connector (connect part C to part D as shown below).  
®
®
COMPATIBLE BRK AND FIRST ALERT MODELS  
NOTE: There may not be enough room for the Adapter Plug and additional  
wiring to fit in the junction box. If not, the old power connector must be  
®
All of the listed BRK Alarms are compatible with the listed KIDDE/  
FYRNETICS/LIFESAVER Alarms and will work with the enclosed Adapter  
®
®
removed and replaced with a First Alert Power Connector.  
Plugs.  
6. Connect the other end of the Adapter Plug to the appropriate Smoke Alarm  
®
(connect part C to part B as shown below).  
BRK Alarms  
7. Check all connections. Make sure all plugs are completely connected and  
snapped together. Ensure the Adapter Plug is securely connected to the  
existing Power Connector.  
4120, 9120 Series – AC, AC/DC Ion, Silence  
5919 – AC Photo  
2002RAC – AC/DC Photo  
7010 Series – AC, AC/DC Photo, Silence  
SC6120B, SC9120B – AC/DC Smoke/CO Combo  
HD6135FB – Heat Alarm  
8. Install the base of the Smoke Alarm to the mounting bracket.  
9. Restore power to the junction box.  
10. Test each Smoke Alarm. Press and hold the test button until the unit alarms.  
When testing a series of interconnected units you must test each unit  
individually. Make sure all units alarm when each one is tested.  
RM3 – Auxiliary Relay  
®
KIDDE/FYRNETICS/LIFESAVER  
1235 Series – AC Ion  
1275 Series – AC/DC Ion, Hush  
1285 Series – AC/DC Ion, Escape Light  
1276 – AC/DC Ion, Hush, Front-Loading Battery  
PE120E, PE120 – AC/DC Photo  
PI2000 – AC/DC Ion/Photo  
The Parts of This Installation  
D
A
HD135F – Heat Alarm  
Maximum of 18 units total may be interconnected, (Maximum of 12  
A
B
Mounting Bracket  
Smoke Alarms plus 6 other devices). Check for model numbers above.  
®
BRK 4120, 9120 Series  
Smoke Alarm  
Adapter Plug (ADK) Diagram for  
®
C
D
ADK Adapter  
KIDDE/FYRNETICS/LIFESAVER Models:  
Plug Pin  
View  
Existing compatible  
power connector  
Side View  
White  
Orange  
Electrical Rating:  
120V AC, 100mA Maximum  
Black  
Not for Current Interruption  
C
NOTE: Twist tie should not be removed.  
NOTE: ADAPTER PLUG CANNOT BE USED TO CONNECT KIDDE CARBON  
MONOXIDE ALARMS.  
®
THE ABOVE MODELS OF KIDDE/FYRNETICS/LIFESAVER ARE THE ONLY  
B
MODELS THAT MAY BE INTERCONNECTED USING ONE OF THE ADAPTER  
PLUGS INCLUDED. IF THE MODEL IS NOT LISTED, IT MUST BE REMOVED  
FROM THE SYSTEM.  
NOTE:  
RECOGNIZED  
COMPONENT  
CONFORMS TO  
UL STANDARD 1977  
Independent evaluation of the  
Adapter Plug and interconnect  
compatibility was performed by  
Intertek, a division of ETL SEMKO.  
INCOMPATIBLE POWER CONNECTORS:  
DO NOT ATTEMPT  
INSTALLATION  
3055574  
© 2007 BRK Brands, Inc., a Jarden Corporation company (NYSE: JAH)  
3901 Liberty Street Road, Aurora, IL 60504-8122  
KIDDE  
NOTE ROUND HOLES  
All rights reserved.  
US Patent No.: 6,641,433 B2  
BRK® is a registered trademark of BRK Brands, Inc.  
First Alert® is a registered trademark of the First Alert Trust.  
Lifesaver® is a registered trademark of Fyrnetics, Inc.  
®
NOTE: Adapter Plug can be used on KIDDE/FYRNETICS/LIFESAVER  
Models manufactured on or before January 1, 2004.  
Printed in Mexico M08-0126-001  
H
06/07  
 

Black Box Computer Accessories gigatrue cat6 component level patch panels User Manual
Black Decker Blender BLM14600DG User Manual
Black Decker Cordless Drill CD632 User Manual
Bodum Charcoal Grill 11478 User Manual
Bosch Power Tools Welding Consumables VDN 240 User Manual
Bryant Furnace 310AAV User Manual
Campbell Manufacturing Switch SDM SW8A User Manual
Carrier Heat Pump 38QP024 User Manual
Casio Calculator MS300M User Manual
Chamberlain Garage Door Opener 1215EM FS2 User Manual